Shinya Onogi

Prof. Shinya Onogi

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2021 in Healthcare
Verified
Journal Article
Open access
PDF file
TSTakaaki Sugino
Takaaki Sugino
TKToshihiro Kawase
Toshihiro Kawase
SOShinya Onogi
Shinya Onogi
TKTaichi Kin
Taichi Kin
NSNobuhito Saito
Nobuhito Saito
YNYOSHIKAZU NAKAJIMA
YOSHIKAZU NAKAJIMA
Brain structure segmentation on magnetic resonance (MR) images is important for various clinical applications. It has been automatically performed by using fully convolutional networks. However, it suffers from the class imbalance problem. To address this problem, we investigated how loss weighting strategies work for brain structure segmentation tasks with different class imbalance situations on MR images. In this study, we adopted segmentation tasks of the cerebrum, cerebellum, brainstem, and blood vessels from MR cisternography and angiography images as the target segmentation tasks. We used a U-net architecture with cross-entropy and Dice loss functions as a baseline and evaluated the effect of the following loss weighting strategies: inverse frequency weighting, median inverse frequency weighting, focal weighting, distance map-based weighting, and distance penalty term-based weighting. In the experiments, the Dice loss function with focal weighting showed the best performance and had a high average Dice score of 92.8% in the binary-class segmentation tasks, while the cross-entropy loss functions with distance map-based weighting achieved the Dice score of up to 93.1% in the multi-class segmentation tasks. The results suggested that the distance map-based and the focal weightings could boost the performance of cross-entropy and Dice loss functions in class imbalanced segmentation tasks, respectively.

1 January 2020 in Cyborg and Bionic Systems
Verified
Journal Article
Open access
PDF file
RNRyu Nakadate
Ryu Nakadate
TITsutomu Iwasa
Tsutomu Iwasa
SOShinya Onogi
Shinya Onogi
JAJumpei Arata
Jumpei Arata
SOSusumu Oguri
Susumu Oguri
MHMakoto Hashizume
Makoto Hashizume
Early-stage gastrointestinal cancer is often treated by endoscopic submucosal dissection (ESD) using a flexible endoscope. Compared with conventional percutaneous surgery, ESD is much less invasive and provides a high quality of life for the patient because it does not require a skin incision, and the organ is preserved. However, the operator must be highly skilled because ESD requires using a flexible endoscope with energy devices, which have limited degrees of freedom. To facilitate easier manipulation of these flexible devices, we developed a surgical robot comprising a flexible endoscope and two articulating instruments. The robotic system is based on a conventional flexible endoscope, and an extrapolated motor unit moves the endoscope in all its degrees of freedom. The instruments are thin enough to allow insertion of two instruments into the endoscope channel, and each instrument has a bending section that allows for up–down, right–left, and forward–backward motion. In this study, we performed anex vivofeasibility evaluation using the proposed robotic system for ESD in a porcine stomach. The procedure was successfully performed by five novice operators without complications. Our findings demonstrated the feasibility of the proposed robotic system and, furthermore, suggest that even operators with limited experience can use this system to perform ESD.

1 November 2024 in Sensors
Verified
Journal Article
Open access
PDF file
TITaku Ito
Taku Ito
TFTaro Fujikawa
Taro Fujikawa
TTTakamori Takeda
Takamori Takeda
YMYoshimaru Mizoguchi
Yoshimaru Mizoguchi
KOKouta Okubo
Kouta Okubo
TTTakeshi Tsutsumi
Takeshi Tsutsumi
Augmented reality technologies provide transformative solutions in various surgical fields. Our research focuses on the use of an advanced augmented reality system that projects 3D holographic images directly into surgical footage, potentially improving the surgeon’s orientation to the surgical field and lowering the cognitive load. We created a novel system that combines exoscopic surgical footage from the “ORBEYE” and displays both the surgical field and 3D holograms on a single screen. This setup enables surgeons to use the system without using head-mounted displays, instead viewing the integrated images on a 3D monitor. Thirteen surgeons and surgical assistants completed tasks with 2D and 3D graphical surgical guides. The NASA Task Load Index was used to assess mental, physical, and temporal demands. The use of 3D graphical surgical guides significantly improved performance metrics in cochlear implant surgeries by lowering mental, physical, temporal, and frustration levels. However, for Bonebridge implantation, the 2D graphical surgical guide performed better overall (p = 0.045). Participants found the augmented reality system’s video latency to be imperceptible, measuring 0.13 ± 0.01 s. This advanced augmented reality system significantly improves the efficiency and precision of cochlear implant surgeries by lowering cognitive load and improving spatial orientation.

4 August 2021 in Electronics
Verified
Journal Article
Open access
PDF file
SOShinya Onogi
Shinya Onogi
TKToshihiro Kawase
Toshihiro Kawase
TSTakaaki Sugino
Takaaki Sugino
YNYOSHIKAZU NAKAJIMA
YOSHIKAZU NAKAJIMA
This paper reports the precision of shape-from-focus (SFF) imaging according to the texture frequencies and window sizes of a focus measure. SFF is one of various depth measurement techniques for optical imaging, such as microscopy and endoscopy. SFF measures the depth of an object according to focus measure, which is generally computed with a fixed window. The window size affects the performance of SFF and should be adjusted for the texture of an object. In this study, we investigated the precision difference of SFF in texture frequencies and by window size. Two experiments were performed: precision validation in texture frequencies with a fixed window size, and precision validation in various window sizes related to pixel-cycle lengths. The first experimental results showed that a smaller window size could not provide a correct focus measure, and the second results showed that a window size that is approximately equal to a pixel-cycle length of the texture could provide better precision. These findings could potentially contribute to determining the appropriate window size of focus measure operation in shape-from-focus reconstruction.

2 August 2021 in Healthcare
Verified
Journal Article
Open access
PDF file
YNYOSHIKAZU NAKAJIMA
YOSHIKAZU NAKAJIMA
TSTakaaki Sugino
Takaaki Sugino
MKMasashi Kobayashi
Masashi Kobayashi
YNYasuhiro Nakashima
Yasuhiro Nakashima
YWYohei Wada
Yohei Wada
KOKenichi Okubo
Kenichi Okubo
Respiratory monitoring is a significant issue to reduce patient risks and medical staff labor in postoperative care and epidemic infection, particularly after the COVID-19 pandemic. Oximetry is widely used for respiration monitoring in the clinic, but it sometimes fails to capture a low-functional respiratory condition even though a patient has breathing difficulty. Another approach is breathing-sound monitoring, but this is unstable due to the indirect measurement of lung volume. Kobayashi in our team is developing a sensor measuring temporal changes in lung volume with a displacement sensor attached across the sixth and eighth ribs. For processing these respiratory signals, we propose the combination of complex-valued wavelet transform and the correlation among spectrum sequences. We present the processing results and discuss its feasibility to detect a low-functional condition in respiration. The result for detecting low-functional respiration showed good performance with a sensitivity of 0.88 and specificity of 0.88 to 1 in its receiver operating characteristic (ROC) curve.

17 May 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TKToshihiro Kawase
Toshihiro Kawase
TSTakaaki Sugino
Takaaki Sugino
SOShinya Onogi
Shinya Onogi
KKKenji Kawashima
Kenji Kawashima
YNYOSHIKAZU NAKAJIMA
YOSHIKAZU NAKAJIMA
Tunable stiffness mechanisms can increase the noninvasiveness and stability of organ manipulation in laparoscopic liver resection. We have developed an organ-grasping device using beam-shaped tunable stiffness mechanism. Increasing the change ratio of stiffness will improve the performance of the device by offering high flexibility when adhering to the liver surface and high rigidity during the manipulation of the liver; however, optimal design of the beam has not been investigated. In this study, we investigate the wavy structure shape of the device that enhances the change in the ratio of stiffness. To increase the stiffness in a high-stiffness state, we used principal stress lines in the device to design the edge curve of the wavy shape material in the beams. We also investigated the arrangement of the wavy shape to decrease the stiffness in a low-stiffness state. Simulation using finite element method showed that the change ratio of stiffness was improved up to 13.0 by the new wavy shape arranged with the uniformly thick bottom of the waves.