Kenji Kawashima

Prof. Kenji Kawashima


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 May 2019 in BMC Biomedical Engineering
Verified
Journal Article
Open access
PDF file
KKKenji Kawashima
Kenji Kawashima
TKTakahiro Kanno
Takahiro Kanno
KTKotaro Tadano
Kotaro Tadano
In this paper, we focus on robots used for laparoscopic surgery, which is one of the most active areas for research and development of surgical robots. We introduce research and development of laparoscope-holder robots, master-slave robots and hand-held robotic forceps. Then, we discuss future directions for surgical robots. For robot hardware, snake like flexible mechanisms for single-port access surgery (SPA) and NOTES (Natural Orifice Transluminal Endoscopic Surgery) and applications of soft robotics are actively used. On the software side, research such as automation of surgical procedures using machine learning is one of the hot topics.

22 March 2018 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
RMRyoken Miyazaki
Ryoken Miyazaki
KHKohei Hirose
Kohei Hirose
YIYoshiya Ishikawa
Yoshiya Ishikawa
TKTakahiro Kanno
Takahiro Kanno
KKKenji Kawashima
Kenji Kawashima
In this paper, a surgical robot system for laparoscopic surgery is proposed. Instead of commanding the manipulator from the remote master console, the proposed system integrates the master controller into the proximal end of the slave manipulator. The slave has a flexible wrist joint, whose bending angle is operated by a joystick on the master. Focusing on suturing of a curved needle, which is a common task in laparoscopic surgery, we developed an active motion transformation method which allows the surgeon to insert the needle easily. When inserting the needle, the proposed system transforms the surgeon's wrist rotation into the rotation about the bent forceps gripper. Positioning performance of the proposed system is evaluated by an experiment. Furthermore, we compared the suturing task performance between the proposed system and conventional forceps. The experimental results show that the proposed system reduces the contact force against an organ model.

6 August 2023 in Sensors and Actuators A: Physical
Verified
Journal Article
Open access
MSMaina Sogabe
Maina Sogabe
FUFlorian Christoffer Uetrecht
Florian Christoffer Uetrecht
TKTakahiro Kanno
Takahiro Kanno
TMTetsuro Miyazaki
Tetsuro Miyazaki
KKKenji Kawashima
Kenji Kawashima

17 November 2023 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
JSJunyi Shen
Junyi Shen
TMTetsuro Miyazaki
Tetsuro Miyazaki
SOShingo Ohno
Shingo Ohno
MSMaina Sogabe
Maina Sogabe
KKKenji Kawashima
Kenji Kawashima
Soft robotics is a swiftly evolving field. Pneumatic actuators are suitable for driving soft robots because of their superior performance. However, their control is challenging due to the hysteresis characteristics. In response to this challenge, we propose an adaptive control method to compensate for the hysteresis of soft actuators. Employing a novel dual pneumatic artificial muscle (PAM) bending actuator, the innovative control approach abates hysteresis effects by dynamically modulating gains within a traditional PID controller corresponding to the predicted variation of the reference trajectory. Through experimental evaluation, we found that the proposed control method outperforms its conventional counterparts regarding tracking accuracy and response speed. Our work reveals a new direction for advancing model-free control in soft actuators.

18 July 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TMTetsuro Miyazaki
Tetsuro Miyazaki
TTToshihiro Tagami
Toshihiro Tagami
DMDaisuke Morisaki
Daisuke Morisaki
RMRyoken Miyazaki
Ryoken Miyazaki
TKToshihiro Kawase
Toshihiro Kawase
KKKenji Kawashima
Kenji Kawashima
Power assistive devices have been developed in recent years. To detect the wearer’s motion, conventional devices require users to wear sensors. However, wearing many sensors increases the wearing time, and usability of the device will become worse. We developed a soft gait assistive suit actuated by pneumatic artificial rubber muscles (PARMs) and proposed its control method. The proposed suit is easy to wear because the attachment unit does not have any electrical sensors that need to be attached to the trainee’s body. A target application is forward walking exercise on a treadmill. The control unit detects the pre-swing phase in the gait cycle using the pressure information in the calf back PARMs. After the detection, the suit assists the trainee’s leg motion. The assist force is generated by the controlled PARM pressure, and the pressure input time is changed appropriately considering the gait cycle time. We conducted walking experiments; (1) verifies the proposed control method works correctly, and (2) verifies whether the gait assistive suit is effective for decreasing muscular activity. Finally, we confirmed that the accurate phase detection can be achieved by using the proposed control method, and the suit can reduce muscular activity of the trainee’s leg.

11 January 2024 in Journal of Robotic Surgery
Verified
Journal Article
Open access
PDF file
YWYusuke Wakasa
Yusuke Wakasa
KHKenichi Hakamada
Kenichi Hakamada
HMHajime Morohashi
Hajime Morohashi
TKTakahiro Kanno
Takahiro Kanno
KTKotaro Tadano
Kotaro Tadano
MMMasaki Mori
Masaki Mori
Assuring communication redundancy during the interruption and establishing appropriate teaching environments for local surgeons are essential to making robotic telesurgery mainstream. This study analyzes robotic telesurgery with telementoring using standard domestic telecommunication carriers. Can multiple carriers guarantee redundancy with interruptions? Three commercial optical fiber lines connected Hirosaki University and Mutsu General Hospitals, 150 km apart. Using Riverfield, Inc. equipment, Hirosaki had a cockpit, while both Mutsu used both a cockpit and a surgeon’s console. Experts provided telementoring evaluating 14 trainees, using objective indices for operation time and errors. Subjective questionnaires addressed image quality and surgical operability. Eighteen participants performed telesurgery using combined lines from two/three telecommunication carriers. Manipulation: over 30 min, lines were cut and restored every three minutes per task. Subjects were to press a switch when noticing image quality or operability changes. Mean time to task completion was 1510 (1186–1960) seconds: local surgeons alone and 1600 (1152–2296) seconds for those under remote instructor supervision, including expert intervention time. There was no significant difference (p = 0.86). The mean error count was 0.92 (0–3) for local surgeons and 0.42 (0–2) with remote instructors. Image quality and operability questionnaires found no significant differences. Results communication companies A, B, and C: the A/B combination incurred 0.17 (0–1) presses of the environment change switch, B/C had 0, and C/A received 0.67 (0–3), showing no significant difference among provider combinations. Combining multiple communication lines guarantees communication redundancy and enables robotic telementoring with enhanced communication security.