Natural phenolic antioxidants are one of the widely studied compounds in life sciences due to their important role in oxidative stress prevention and repair. The structural similarity of these antioxidants and their simultaneous presence in the plant samples stipulate the development of methods for their quantification. The current work deals with the simultaneous determination of vanillin and its bioprecursor ferulic acid using a voltammetric sensor for the first time. A sensor based on the layer-by-layer deposition of the polyaminobenzene sulfonic acid functionalized single-walled carbon nanotubes (f-SWCNTs) and electropolymerized bromocresol purple has been developed for this purpose. The best response of co-existing target analytes was registered for the polymer obtained from the 25 µM dye by 10-fold potential cycling from 0.0 to 1.2 V with the scan rate of 100 mV s−1 in 0.1 M phosphate buffer (PB), pH 7.0. Scanning electron microscopy (SEM), cyclic voltammetry and electrochemical impedance spectroscopy (EIS) confirmed the effectivity of the sensor developed. The linear dynamic ranges of 0.10–5.0 µM and 5.0–25 µM for both analytes with the detection limits of 72 nM and 64 nM for ferulic acid and vanillin, respectively, were achieved in differential pulse mode. The sensor was applied for the analysis of vanilla extracts.
Sensors with electrochemically formed polymeric films as a sensitive layer are of high interest in electroanalysis. Voltammetric sensors based on the glassy carbon electrodes (GCEs) covered with carbon nanomaterials and electropolymerized phenolic acids (gallic and ellagic) or triphenylmethane dyes (thymolphthalein and aluminon) were developed. Conditions of potentiodynamic electropolymerization were optimized. The electrodes were characterized with scanning electron microscopy, cyclic voltammetry, chronoamperometry, and electrochemical impedance spectroscopy (EIS). In the differential pulse mode, sensors provided a sensitive and selective response to different classes of the antioxidants (capsaicinoids, flavanones, and flavonols). The practical applicability of the sensors was demonstrated on food and plant samples.
Natural phenolic antioxidants are extensively studied compounds due to their positive health effect and wide distribution in human diets. The simultaneous occurrence in samples requires selective methods for their determination. Electrochemical sensor based on the polyaminobenzene sulfonic acid functionalized single-walled carbon nanotubes (f-SWCNT) and electropolymerized bromocresol purple has been developed for the simultaneous quantification of ferulic acid and vanillin. The electrode has been characterized by scanning electron microscopy (SEM) and electrochemical methods, and the effectivity of the developed modifier has been confirmed. Thus, the novel sensitive voltammetric sensor is simple to fabricate, reliable, cost-effective, and can be applied for foodstuff screening.
Phenolic antioxidants of various groups are important nutrients in the human diet, providing positive health effects. Nevertheless, these effects are dose dependent and require the control of natural phenolic contents in their sources. Coffee and citrus juices containing significant amounts of hydroxycinnamic acids and flavanones, respectively, are among the most widely consumed beverages all over the world. The electroactivity of phenolics allows the application of voltammetric sensors for quantification purposes. Highly sensitive and selective voltammetric sensors for the simultaneous quantification of hydroxycinnamic (caffeic (CA), ferulic (FA), and p-coumaric(p-CA)) acids and flavanones (hesperidin and naringin) have been developed for the first time using glassy carbon electrodes modified with single-walled carbon nanotubes functionalized via polyaminobenzene sulfonic acid (f-SWCNTs) and polymeric coverages from triphenylmethane dyes (phenol red (PR) or aluminon). Polymeric layers have been obtained in potentiodynamic modes. The conditions of the dye’s electropolymerization have been optimized using the voltammetric response of hydroxycinnamic acids or flavanone mixtures. Three separated oxidation peaks of CA, FA, and p-CA at the electrode with polyPR as well as hesperidin and naringin at the polyaluaminon-modified electrode have been observed. The oxidation currents are significantly increased comparing those at the bare glassy carbon (GCE) and carbon nanotube-modified electrodes. Both sensors provide a highly sensitive response to target analytes in the differential pulse voltammetric mode. Other natural phenolics of various classes do not affect the response of the sensors developed to the target analyte. The quantification of hydroxycinnamic acids in coffee and flavanones in orange and grapefruit juices has been successfully realized.
Chemically modified electrodes based on polymer nanocoatings as sensitive layers are some of the intensively developed areas in modern electroanalysis. Electropolymerization of compounds containing phenolic fragments is a promising approach for electrode surface modification. Novel electrodes based on a combination of carbon nanotubes and electropolymerized ellagic acid or aluminon were developed for the direct quantification of flavanones (naringin and hesperidin)—the major flavonoids of Citrus fruits. The conditions of monomers’ potentiodynamic electropolymerization were optimized. Electrode surfaces were characterized by scanning electron microscopy and electrochemical methods. A glassy carbon electrode (GCE) modified with multi-walled carbon nanotubes (MWCNTs) and poly(ellagic acid) allowed for the quantification of naringin in the ranges of 0.050–1.0 and 1.0–100 µM with the detection and quantification limits of 14 and 47 nM, respectively. Simultaneous voltammetric quantification of naringin and hesperidin in the ranges of 0.10–2.5 and 2.5–25 µM for both analytes with the detection limits of 20 nM and 29 nM for naringin and hesperidin, respectively, was achieved on GCE modified with polyaminobenzene sulfonic acid functionalized single-walled carbon nanotubes (f-SWCNTs) and polyaluminon. High selectivity of the electrodes’ responses to flavanones in the presence of typical interferences and natural phenolics was confirmed. The approaches were successfully applied to Citrus juices.
Hydroxycinnamic acids are one of the most widely distributed classes of natural phenolics in plants. Their coexistence requires selective methods for quantification. Voltammetry on chemically modified electrodes is one of the approaches to solving this problem. Electrodes based on electropolymerized triphenylmethane dyes give sensitive and selective responses to natural phenolic antioxidants of different classes. In this work, a combination of polyaminobenzene sulfonic acid functionalized single-walled carbon nanotubes (f-SWCNTs), and poly(phenol red) was used as an electrode surface modifier. The polymeric coverage was obtained by potentiodynamic electropolymerization, the conditions of which were optimized on the basis of the voltammetric response of the hydroxycinnamic acid mixture. Poly(phenol red)-based electrodes provided well-resolved peaks of caffeic, ferulic, and p-coumaric acids, and a significant increase in the oxidation currents compared to bare glassy carbon (GCE) and f-SWCNTs-modified electrodes. Simultaneous voltammetric quantification of caffeic, ferulic, and p-coumaric acids was performed for the first time. Two linear dynamic ranges of 0.10–2.5 µM for all acids, 2.5–100 µM for caffeic acid, and 2.5–50 µM for ferulic and p-coumaric acids were achieved using differential pulse voltammetry in a Britton–Robinson buffer with a pH of 2.0. The limits of detection were 47.6, 22.4, and 38.0 nM for the caffeic, ferulic, and p-coumaric acids, respectively.