The quality of the scan image is important in peripapillary circulation analysis using optical coherence tomography angiography (OCTA). We aimed to investigate the effects of signal strength (SS) on the peripapillary microvascular density acquired from OCTA. A total of 259 eyes from 259 young healthy subjects were included. Peripapillary OCTA images using 3 × 3 mm angiography scan were acquired from all participants. Subjects were divided into four groups according to the SS: SS 7, SS 8, SS 9, and SS 10. Vessel density (VD) and perfusion density (PD) of the superficial capillary plexus were calculated. VD and PD were compared among the four groups, and linear regression analyses were performed to identify and evaluate the clinical factors associated with average VD. As the SS increased from 7 to 10, the average VD and PD increased; these increases were statistically significant (all, p < 0.001). Regression analyses showed that four factors were significantly correlated with average VD: age (partial r = 0.133), average retinal nerve fiber layer thickness (partial r = 0.169), cup/disc ratio (partial r =−0.481), and SS (partial r = 0.413). SS is a significant factor affecting peripapillary microvascular density, and its influence is similar to well-known structural parameters associated with glaucoma.
Background/Aims To investigate whether the association of long-term intraocular pressure (IOP) fluctuation with the rate of progression of normal-tension glaucoma (NTG) differs between myopia and non-myopia. Methods The medical records of 65 myopic NTG (axial length (AL) > 24.0 mm) and 64 non-myopic NTG eyes (AL < 24.0 mm), who had been treated with topical medications for more than 5 years, were reviewed. Multiple linear regression models were fitted to analyse the relationships of the slope of mean deviation (MD) or visual field index (VFI) with the clinical factors, including the interactions with myopia. Results The average follow-up period was 8.3 years. Twenty-two (22) non-myopic eyes (34.4%) and 27 myopic eyes (41.5%) showed NTG progression (p=0.511). The interaction of myopia with IOP fluctuation was a significant factor regarding both MD and VFI slope (p=0.002, 0.024, respectively); stratified analyses suggested that the risk effect of IOP fluctuation was significant only in myopic NTG in terms of both MD (β= −1.27, p=0.003) and VFI slope (β=−2.32, p=0.011). Conclusion Long-term IOP fluctuation was significantly related to faster visual field progression in myopic NTG eyes, compared with non-myopic NTG eyes.
Background To investigate the relationship between estimated mean ocular perfusion pressure (MOPP) and peripapillary perfusion density (PD) or vessel density (VD) as measured by spectral-domain optical coherence tomography angiography (OCTA) in young healthy eyes. Methods 132 healthy participants (264 eyes) under 45 years of age underwent optic disc OCTA scan sized 3×3 mm to acquire PD and VD in the superficial vascular complex (SVC). Optic nerve head (ONH) parameters including retinal nerve fibre layer (RNFL) thickness, rim area and disc area were measured. MOPP was estimated from systemic blood pressure and intraocular pressure (IOP). A linear mixed model was used to find the systemic and ocular factors associated with PD and VD. Results The average age of the subjects was 25.8±6.5 years. PD and VD showed a significant correlation with RNFL thickness (r=0.224, p<0.001 and r=0.214, p<0.001, respectively), but with MOPP, the correlation was only marginally significant (r=0.105, p=0.09 and r=0.112, p=0.07, respectively). After controlling for confounding factors, including age, sex, IOP, central corneal thickness, axial length and OCTA signal strength, PD and VD were significantly associated with ONH parameters (all p0.05). Conclusion PD and VD in the SVC were significantly associated with ONH parameters while showing no association with estimated MOPP. OCTA-derived VD may not represent perfusion pressure, but is rather more dependent on peripapillary structure.
Visual field assessment is recognized as the important criterion of glaucomatous damage judgement; however, it can show large test–retest variability. We developed a deep learning (DL) algorithm that quantitatively predicts mean deviation (MD) of standard automated perimetry (SAP) from monoscopic optic disc photographs (ODPs). A total of 1200 image pairs (ODPs and SAP results) for 563 eyes of 327 participants were enrolled. A DL model was built by combining a pre-trained DL network and subsequently trained fully connected layers. The correlation coefficient and mean absolute error (MAE) between the predicted and measured MDs were calculated. The area under the receiver operating characteristic curve (AUC) was calculated to evaluate the detection ability for glaucomatous visual field (VF) loss. The data were split into training/validation (1000 images) and testing (200 images) sets to evaluate the performance of the algorithm. The predicted MD showed a strong correlation and good agreement with the actual MD (correlation coefficient = 0.755; R2 = 57.0%; MAE = 1.94 dB). The model also accurately predicted the presence of glaucomatous VF loss (AUC 0.953). The DL algorithm showed great feasibility for prediction of MD and detection of glaucomatous functional loss from ODPs.
2 February 2022 in American Journal of Ophthalmology