Thomas Wucherpfennig

Dr. Thomas Wucherpfennig


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 May 2021 in Processes
Verified
Journal Article
Open access
PDF file
MKMaike Kuschel
Maike Kuschel
JFJürgen Fitschen
Jürgen Fitschen
MHMarko Hoffmann
Marko Hoffmann
AKAlexandra von Kameke
Alexandra von Kameke
Michael SchlueterMichael Schlueter
Michael Schlueter
TWThomas Wucherpfennig
Thomas Wucherpfennig
Detailed process and equipment knowledge is crucial for the successful production of biopharmaceuticals. An essential part is the characterization of equipment for which Computational Fluid Dynamics (CFD) is an important tool. While the steady, Reynolds-averaged Navier–Stokes (RANS) k − ε approach has been extensively reviewed in the literature and may be used for fast equipment characterization in terms of power number determination, transient schemes have to be further investigated and validated to gain more detailed insights into flow patterns because they are the method of choice for mixing time simulations. Due to the availability of commercial solvers, such as M-Star CFD, Lattice Boltzmann simulations have recently become popular in the industry, as they are easy to set up and require relatively low computing power. However, extensive validation studies for transient Lattice Boltzmann Large Eddy Simulations (LB LES) are still missing. In this study, transient LB LES were applied to simulate a 3 L bioreactor system. The results were compared to novel 4D particle tracking (4D PTV) experiments, which resolve the motion of thousands of passive tracer particles on their journey through the bioreactor. Steady simulations for the determination of the power number followed a structured workflow, including grid studies and rotating reference frame volume studies, resulting in high prediction accuracy with less than 11% deviation, compared to experimental data. Likewise, deviations for the transient simulations were less than 10% after computational demand was reduced as a result of prior grid studies. The time averaged flow fields from LB LES were in good accordance with the novel 4D PTV data. Moreover, 4D PTV data enabled the validation of transient flow structures by analyzing Lagrangian particle trajectories. This enables a more detailed determination of mixing times and mass transfer as well as local exposure times of local velocity and shear stress peaks. For the purpose of standardization of common industry CFD models, steady RANS simulations for the 3 L vessel were included in this study as well.

16 May 2024 in Fluids
Verified
Journal Article
Open access
PDF file
VBVincent Bernemann
Vincent Bernemann
JFJürgen Fitschen
Jürgen Fitschen
MLMarco Leupold
Marco Leupold
KSKarl-Heinz Scheibenbogen
Karl-Heinz Scheibenbogen
Marc MalyMarc Maly
Marc Maly
Michael SchlueterMichael Schlueter
Michael Schlueter
The reliable transfer of bioprocesses from single-use bioreactors (SUBs) of different scales to conventional stainless steel stirred-tank bioreactors is of steadily growing interest. In this publication, a scale-up study for SUBs with volumes of 200 L and 2000 L and the transfer to an industrial-scale conventional stainless steel stirred-tank bioreactor with a volume of 15,000 L is presented. The scale-up and transfer are based on a comparison of mixing times and the modeling of volumetric mass transfer coefficients kLa, measured in all three reactors in aqueous PBS/Kolliphor solution. The mass transfer coefficients are compared with the widely used correlation of van’t Riet at constant stirrer tip speeds. It can be shown that a van’t Riet correlation enables a robust and reliable prediction of mass transfer coefficients on each scale for a wide range of stirrer tip speeds and aeration rates. The process transfer from single-use bioreactors to conventional stainless steel stirred-tank bioreactors is proven to be uncritical concerning mass transfer performance. This provides higher flexibility with respect to bioreactor equipment considered for specific processes.

18 January 2023 in Frontiers in Chemical Engineering
Verified
Journal Article
Open access
MKMaike Kuschel
Maike Kuschel
JWJohannes Wutz
Johannes Wutz
MSMustafa Salli
Mustafa Salli
DMDominique Monteil
Dominique Monteil
TWThomas Wucherpfennig
Thomas Wucherpfennig
The robust scale up of perfusion systems requires comparable conditions over all scales to ensure equivalent cell culture performance. As cells in continuous processes circulate outside the bioreactor, performance losses may arise if jet flow and stirring cause a direct connection between perfusion feed and return. Computational fluid dynamics can be used to identify such short circuit flows, assess mixing efficiencies, and eventually adapt the perfusion setup. This study investigates the scale up from a 2 L glass bioreactor to 100 L and 500 L disposable pilot scale systems. Highly resolved Lattice Boltzmann Large Eddy simulations were performed in single phase and mixing efficiencies (Emix) furthermore experimentally validated in the 2 L system. This evaluation gives insight into the flow pattern, the mixing behavior and information on cell residence time inside the bioreactors. No geometric adaptations in the pilot scale systems were necessary as Emix was greater than 90% for all conditions tested. Two different setups were evaluated in 2 L scale where the direction of flow was changed, yielding a difference in mixing efficiency of 10%. Nevertheless, since Emix was confirmed to be >90% also for both 2 L setups and the determined mixing times were in a similar range for all scales, the 2 L system was deemed to be a suitable scale down model. The results demonstrate how computational fluid dynamic models can be used for rational process design of intensified production processes in the biopharmaceutical industry.

1 January 2023
Verified
Book Chapter
Closed access
PDF file
JFJürgen Fitschen
Jürgen Fitschen
SHSebastian Hofmann
Sebastian Hofmann
LKLotta Kursula
Lotta Kursula
IHIngrid Haase
Ingrid Haase
TWThomas Wucherpfennig
Thomas Wucherpfennig
Michael SchlueterMichael Schlueter
Michael Schlueter

30 October 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
MKMarco Kunzelmann
Marco Kunzelmann
AWAnja Wittmann
Anja Wittmann
BPBeate Presser
Beate Presser
PBPhilipp Brosig
Philipp Brosig
PMPia Kristin Marhoffer
Pia Kristin Marhoffer
TWThomas Wucherpfennig
Thomas Wucherpfennig
Within process development, numerous experimental studies are undertaken to establish, optimize and characterize individual bioprocess unit operations. These studies pursue diverse objectives such as enhancing titer or minimizing impurities. Consequently, Design of Experiment (DoE) studies are planned and analyzed independently from each other, making it challenging to interlink individual data sets to form a comprehensive overview at the conclusion of the development process. This paper elucidates the methodology for constructing a Life-Cycle-DoE (LDoE), which integrates data-driven process knowledge through design augmentations. It delves into the strategy, highlights the challenges encountered and provides solutions for overcoming them. The LDoE approach facilitates the augmentation of an existing model with new experiments in a unified design. It allows for flexible design adaptations as per the requirements of subject matter experts (SME) during process development, concurrently enhancing model predictions by utilizing all available data. The LDoE boasts a broad application spectrum as it consolidates all data generated within bioprocess development into a single file and model. The study demonstrates that the LDoE approach enables a process characterization study (PCS) to be performed solely with development data. Furthermore, it identifies potentially critical process parameters (pCPPs) early, allowing for timely adaptations in process development to address these challenges.

21 January 2026 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
SPS. Piontek
S. Piontek
JFJ. Fitschen
J. Fitschen
CWC. Weiland
C. Weiland
THT. Habicher
T. Habicher
MSM. Schlüter
M. Schlüter
TWThomas Wucherpfennig
Thomas Wucherpfennig
Wave bioreactors are commonly used in biopharmaceutical upstream processes as an intermediate stage between shake flasks and stirred tanks within the seed train. They offer a controlled environment for cell cultivation while minimizing shear stress. Accurate characterization of these systems is essential for optimizing cell culture performance, particularly as state of the art cell lines require higher volumetric mass transfer coefficients k L a . This study aims to determine the volumetric mass transfer coefficient through experiments and computational fluid dynamics (CFD) simulations. An improved experimental method for the measurements of the volumetric mass transfer is presented, with results correlated to key process parameters: rocking angle, rocking rate, and filling volume. In addition, CFD simulations were caried out using M-Star CFD by means of a Lattice-Boltzmann Method-based solver. The mass transfer was calculated using Higbie’s penetration theory, incorporating the Kolmogorov scale to define contact time. The analysis also integrates concepts from Friedl and the surface renewal model, introducing the surface normal velocity as an additional parameter in the mass transfer coefficient k L calculation. Analyzes were carried out for 10 and 50 L wave bioreactors, with one degree of freedom movement. Optimized process parameters were identified and validated in biological cultivations, resulting in increased dissolved oxygen levels in the medium. These findings contribute to improved characterization and control of wave bioreactors, enabling more accurate prediction of process parameter effects.