Yong-Joo Lee

Prof. Dr. Yong-Joo Lee


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Global Health Action
Verified
Journal Article
Open access
SCSeungman Cha
Seungman Cha
PMPaul Mansiangi Mankadi
Paul Mansiangi Mankadi
MEMousab Siddig Elhag
Mousab Siddig Elhag
YLYong-Joo Lee
Yong-Joo Lee
YJYan Jin
Yan Jin
Background: As the Millennium Development Goals ended, and were replaced by the Sustainable Development Goals, efforts have been made to evaluate the achievements and performance of official development assistance (ODA) in the health sector. In this study, we explore trends in the expansion of water and sanitation coverage in developing countries and the performance of ODA. Design: We explored inequality across developing countries by income level, and investigated how ODA for water and sanitation was committed by country, region, and income level. Changes in inequality were tested via slope changes by investigating the interaction of year and income level with a likelihood ratio test. A random effects model was applied according to the results of the Hausman test. Results: The slope of the linear trend between economic level and sanitation coverage has declined over time. However, a random effects model suggested that the change in slope across years was not significant (e.g. for the slope change between 2000 and 2010: likelihood ratio χ2 = 2.49, probability > χ2 = 0.1146). A similar pro-rich pattern across developing countries and a non-significant change in the slope associated with different economic levels were demonstrated for water coverage. Our analysis shows that the inequality of water and sanitation coverage among countries across the world has not been addressed effectively during the past decade. Our findings demonstrate that the countries with the least coverage persistently received far less ODA per capita than did countries with much more extensive water and sanitation coverage, suggesting that ODA for water and sanitation is poorly targeted. Conclusion: The most deprived countries should receive more attention for water and sanitation improvements from the world health community. A strong political commitment to ODA targeting the countries with the least coverage is needed at the global level.

2 May 2021 in International Journal of Geo-Engineering
Verified
Journal Article
Open access
PDF file
SKSuk -Min Kong
Suk -Min Kong
DODong-Wook Oh
Dong-Wook Oh
SLSo-Yeon Lee
So-Yeon Lee
HJHyuk-Sang Jung
Hyuk-Sang Jung
YLYong-Joo Lee
Yong-Joo Lee
Reinforced retaining walls are structures constructed horizontally to resist earth pressure by leveraging the frictional force imparted by the backfill. Reinforcements are employed because they exhibit excellent safety and economic efficiency. However, insufficient reinforcement can lead to collapse, and excessive reinforcement reduces economic efficiency. Therefore, it is important to select the appropriate type, length, and spacing of reinforcements. However, in actual sites, although the stress and fracture mechanisms in the straight and curved sections of reinforced soil retaining walls differ, the same amount of reinforcements are typically installed. Such an approach can lead to wall collapse or reduce economic feasibility. Therefore, in this study, the behaviours of straight and curved sections fortified with reinforcements of various lengths (1, 3, 5, and 7 m) are predicted through a three-dimensional numerical analysis. The retaining walls are of the same height, but the reinforcement variations in the aforementioned sections influence the wall behaviour differently. Based on the results, the optimum reinforcement lengths for the straight and curved parts were selected. By installing reinforcements of different lengths in these sections, the maximum reinforcing effect with minimum reinforcement was derived. This study further found that the curved section of the wall required more reinforcements, and the reinforcement lengths for the curved and straight sections should be separately optimized.

30 January 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YKYoung Je Kim
Young Je Kim
HJHyuk Sang Jung
Hyuk Sang Jung
YLYong-Joo Lee
Yong-Joo Lee
DODong-Wook Oh
Dong-Wook Oh
MSmin son
min son
YHYoon HwanHee
Yoon HwanHee
Reinforced soil retaining wall are ground structures that can be readily seen all around us. The development of reinforcements to these walls and their demand have increased rapidly. These walls are advantageous because they can be used not only in simple construction compared with reinforced concrete retaining walls but also when the height of the wall needs to be higher. However, unlike reinforced concrete retaining walls, in which the walls are integrated and resist the earth pressure on the back, the block-type reinforced earth retaining wall method secures its structural stability by frictional force between the buried land and reinforcements. A phenomenon in which a block is cracked or dropped owing to deformation has been frequently reported. In particular, this phenomenon is concentrated at the curved parts of a reinforced soil retaining wall and is mainly known as a stress concentration. However, to date, the design of reinforced soil retaining walls has been limited by the two-dimensional plane strain condition and has not considered the characteristics of the curved part. There is a lack of research on curved part. Therefore, this research determines the behavioural characteristics of curved-part reinforced soil retaining walls with regard to the shape (convex or concave) and angle (60°, 90°, 120°, and 150°). The displacement generated in the straight part and the curved part was analysed through an Laboratory Scale Test. The results showed that the horizontal displacement of the curved part increases as a convex angle becomes smaller, and the horizontal displacement of the curved part decreases as a concave angle becomes smaller. At the center (D and H have the same length, but H represents the height and D represents the separation distance from the center of the curved part) of the convex curve, the horizontal displacement of the 0.5 D section decreased to 13.8%; it decreased to 41.0% in the 1.0 D section. For concave angles, it was revealed that the horizontal displacement from the center 0.0 D to the 0.5 D section of the curved part increased by 25%, and from the 1.0 D section, by 75%. It was confirmed that the displacement difference was largely based on the value of 0.5 D. It was judged that this can be used as basic data for the design and construction guidelines for reinforced soil retaining wall of reinforced soil retaining walls.

15 May 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DODong-Wook Oh
Dong-Wook Oh
SKSuk-Min Kong
Suk-Min Kong
SKSu-Bin Kim
Su-Bin Kim
YLYong-Joo Lee
Yong-Joo Lee
Tunneling, especially in urban areas, affects many structures on the ground, which directly influences the usability and stability of the structures. The settlement of and axial stress on the pile foundation are important factors that determine the behavioral characteristics of the pile foundation. Therefore, this study uses numerical analysis and machine learning to derive a prediction model of pile axial stress due to tunnel excavation adjacent to the piled raft. Numerical analysis data were utilized for machine learning purposes, and the effects of the input data on the prediction model were scrutinized. The numerical analysis revealed that the change in the pile axial stress resulting from tunnel excavation differed depending on the pile’s location, with the greatest axial stress reduction occurring in the center of the piled raft. Furthermore, the rate of reduction was higher in soils with lower relative densities. Several algorithms were employed to derive the prediction model, with tree-based algorithms displaying notable performance in predicting pile axial stress. Additionally, preprocessing the data with appropriate feature engineering techniques exhibited superior predictive power, and incorporating settlement data aided in enhancing the prediction model’s performance.

28 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DODong-Wook Oh
Dong-Wook Oh
SKSuk-Min Kong
Suk-Min Kong
YLYong-Joo Lee
Yong-Joo Lee
HPHeon-Joon Park
Heon-Joon Park
For tunneling in urban areas, understanding the interaction and behavior of tunnels and the foundation of adjacent structures is very important, and various studies have been conducted. Superstructures in urban areas are designed and constructed with piled rafts, which are more effective than the conventional piled foundation. However, the settlement of a piled raft induced by tunneling mostly focuses on raft settlement. In this study, therefore, raft and pile settlements were obtained through 3D numerical analysis, and the change rate of settlement along the pile length was calculated by linear assumption. Machine learning was utilized to develop prediction models for raft and pile settlement and change rate of settlement along the pile length due to tunneling. In addition, raft settlement in the laboratory model test was used for the verification of the prediction model of raft settlement, derived through machine learning. As a result, the change rate of settlement along the pile length was between 0.64 and −0.71. In addition, among features, horizontal offset pile tunnel had the greatest influence, and pile diameter and number had relatively little influence.

27 July 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SKSuk-Min Kong
Suk-Min Kong
DODong-Wook Oh
Dong-Wook Oh
SLSeong-Won Lee
Seong-Won Lee
CKChang-Yong Kim
Chang-Yong Kim
YLYong-Joo Lee
Yong-Joo Lee
Vital underground structures such as sewers, power transmission lines, subways, and underpasses are potentially vulnerable to adverse effects from aboveground construction. In this study, the influence of pile installation on nearby existing tunnels was investigated. Both a laboratory model test and finite-element numerical analysis were conducted. Twelve different combinations of horizontal and vertical offsets between the pile and the tunnel were investigated. Different surcharge loads (allowable and ultimate) were also considered. In this way, the appropriate separation distance between the existing tunnel and the piles was established for sandy, medium-compaction soil. Although this study considers simple ground conditions, it facilitates safe construction by confirming the appropriate separation distance and comparing the areas that cannot be penetrated by the structures of each standard.