Linxiao Cong

Dr. Linxiao Cong

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 July 2021 in Symmetry
Verified
Journal Article
Open access
PDF file
LCLinxiao Cong
Linxiao Cong
JMJianchao Mu
Jianchao Mu
QLQian Liu
Qian Liu
HWHao Wang
Hao Wang
LWLinlin Wang
Linlin Wang
Cong Feng QiaoCong Feng Qiao
Cong Feng Qiao
The space gravitational wave detection and drag free control requires the micro-thruster to have ultra-low thrust noise within 0.1 mHz–0.1 Hz, which brings a great challenge to calibration on the ground because it is impossible to shield any spurious couplings due to the asymmetry of torsion balance. Most thrusters dissipate heat during the test, making the rotation axis tilt and components undergo thermal drift, which is hysteretic and asymmetric for micro-Newton thrust measurement. With reference to LISA’s research and coming up with ideas inspired from proportional-integral-derivative (PID) control and multi-timescale (MTS), this paper proposes to expand the state space of temperature to be applied on the thrust prediction based on fine tree regression (FTR) and to subtract the thermal noise filtered by transfer function fitted with z-domain vector fitting (ZDVF). The results show that thrust variation of diurnal asymmetry in temperature is decoupled from 24 μN/Hz1/2 to 4.9 μN/Hz1/2 at 0.11 mHz. Additionally, 1 μN square wave modulation of electrostatic force is extracted from the ambiguous thermal drift background of positive temperature coefficient (PTC) heater. The PID-FTR validation is performed with experimental data in thermal noise decoupling, which can guide the design of thermal control and be extended to other physical quantities for noise decoupling.

27 January 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JMJianchao Mu
Jianchao Mu
LCLinxiao Cong
Linxiao Cong
QHQiwei Hu
Qiwei Hu
Cong Feng QiaoCong Feng Qiao
Cong Feng Qiao
Numerical research on an electrostatic lantern rings calibration structure is conducted to produce an electrostatic driving force in the range of 0-2.25 mN. The driving force is the electrostatic attraction generated when a potential difference is applied between a set of oppositely arranged lantern rings. The electrostatic potential, electric field distribution, and force generated at different voltages are obtained. Due to the axial symmetry of electrostatic lantern rings, the radial electrostatic force component is balanced and the electrostatic force mainly acts in the axial direction. When the engagement distance of the rings is within 3-6 mm, the deflection angle does not exceed 2°, or the radial offset does not exceed 0.3 mm, the electrostatic force deviation is less than 5%. Electrostatic lantern rings provide an accurate and practical alternative method for thrust stand calibration.

21 December 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LCLinxiao Cong
Linxiao Cong
JWJiabin Wang
Jiabin Wang
JLJianfei Long
Jianfei Long
JMJianchao Mu
Jianchao Mu
HDHaoye Deng
Haoye Deng
Cong Feng QiaoCong Feng Qiao
Cong Feng Qiao
To enhance the accuracy of micro-Newton thrust measurements via a torsion pendulum, addressing microgravity coupling effects caused by platform tilt and pendulum mass eccentricity is crucial. This study focuses on analyzing and minimizing these effects by alleviating reference surface tilt and calibrating the center of mass during thrust measurements. The study introduced analysis techniques and compensation measures. It first examined the impact of reference tilt and center of mass eccentricity on the stiffness and compliance of the torsion pendulum by reconstructing its dynamic model. Simscape Multibody was initially employed for numerical analysis to assess the dynamic coupling effects of the tilted pendulum. The results showed the influence of reference tilt on the stiffness and compliance of the torsion pendulum through simulation. An inverted pendulum was developed to amplify the platform’s tilt angle for microgravity drag-free control. Center of mass calibration can identify the gravity coupling caused by the center of mass position. Based on the displacement signal from the capacitive sensor located at the end of the inverted pendulum, which represents the platform’s tilt angle, the pendulum’s vibration at 0.1 mHz was reduced from 5.7 μm/Hz1/2 to 0.28 μm/Hz1/2 by adjusting the voltage of piezoelectric actuator. Finally, a new two-stage torsion pendulum structure was proposed to decouple the tilt coupling buried in both pitch and roll angle. The study utilized theoretical models, numerical analysis, and experimental testing to validate the analysis methods and compensation measures for microgravity coupling effects in torsion pendulums. This led to a reduction in low-frequency noise caused by ground vibrations and thermal strains, ultimately improving the micro-Newton thrust measurement accuracy of the torsion pendulum through the platform’s drag-free control.

2 June 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JWJiabin Wang
Jiabin Wang
JLJianfei Long
Jianfei Long
JXJiawen Xu
Jiawen Xu
MWMingshan Wu
Mingshan Wu
LCLinxiao Cong
Linxiao Cong
NGNing Guo
Ning Guo
Sub-micro-Newton thrusters on space satellites are widely used in spaceborne gravitational wave detection, making accurate measurement of micro-thrust-generated thrust essential. Moreover, micro-propulsion systems often exhibit substantial mass, posing challenges for thrust measurement. This research prompted the development of a sub-micro-thrust measurement device based on the inverted pendulum principle, which with-stands 8 kg loads and boasts a large thrust-to-weight ratio exceeding 109. Experimental results demonstrate that adjusting the stiffness of the inverted pendulum can effectively enhance the resolution of the device. Piecewise constant signal (PCS) thrust force was introduced, and the nonlinear total variation denoising (TVD) algorithm method was adopted for signal denoising. It is validated that thrust measurement in the range of 0–261 μN is achieved with a minimum resolution of 24 nN. The device design and stiffness adjustment method proposed in this paper, as well as the data denoising method utilized, greatly enhance the thrust resolution measurement. This approach enables the development of an accurate micro-thrust model for spaceborne gravitational wave detection missions while simultaneously offering a novel solution for sub-micro-newton-level thrust measurement under heavy load conditions.

5 December 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JWJiabin Wang
Jiabin Wang
JLJianfei Long
Jianfei Long
XWXiaolei Wang
Xiaolei Wang
YWYing Wang
Ying Wang
SJSujin Ji
Sujin Ji
NGNing Guo
Ning Guo
This study introduces a new closed-loop dynamic micro-thrust measurement method based on torsional pendulum is proposed, addressing the poor real-time performance and insufficient precision inherent in traditional open-loop techniques that rely on extreme displacement values to estimate thrust. This method achieves PID closed-loop control through electromagnetic force compensation, tracking the thrust to be measured in real-time. The measurement results are directly inverted from the compensation force. Experimental results show that the dynamic thrust of the electromagnetic calibration system within 0.8 Hz is highly consistent with the calibration results of a high-precision balance with R2 = 0.99895. In closed-loop mode, the phase lag for 20 μN dynamic thrust measurement is only 0.5425°, with a root mean square error as low as 1.82%. The system’s expanded uncertainty is 1.79% below the intrinsic frequency of 11.57 mHz, providing a reliable ground-based verification solution for spacecraft drag-free control and high-frequency dynamic thrust measurement.

31 May 2021 in Preprints.org
Verified
Preprint
Open access
LCLinxiao Cong
Linxiao Cong
JMJian-Chao Mu
Jian-Chao Mu
QLQian Liu
Qian Liu
HWHao Wang
Hao Wang
LWLin-Lin Wang
Lin-Lin Wang
CQCong-Feng Qiao
Cong-Feng Qiao
The space gravitational wave detection and drag free control requires the micro-thruster to have very low thrust noise within 0.1mHz~100mHz, which poses a great challenge to the ground thrust test. The evaluation and decoupling of thermal noise are the difficulties in the application of torsion balance for most thrusters dissipate heat in the experiment. The research has adopted a calibration scheme of micro-Newton thrust torsion balance. On the basis of Lisa Pathfinder's former research and using ideas inspired from PID control and multi time scale (MTS) for reference, the paper proposes to expand the state space of temperature to be applied on thrust prediction based on fine tree regression (FTR), to subtract the thermal noise filtered by transfer function fitted with z-domain vector fitting (ZDVF). The results show that the thrust amplitude thrust density in diurnal temperature fluctuation is decoupled from 24μN/Hz1/2 to 4.9μN/Hz1/2 at 0.11mHz. And the 1μN square wave modulations of electrostatic fins (ESF) is extracted from the simultaneously ambiguous background of temperature for PTC's heating and cooling. The FTR method is well demonstrated in thermal noise decoupling and can guide the design of thermal control and be extended to other physical quantities for noise decoupling.