Jianfei Long

Jianfei Long

Auto-generated profile, based on publicly available information

Jianfei Long

Institute for Advanced Study, University of Chinese Academy of Sciences, Hangzhou, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LCLinxiao Cong
Linxiao Cong
JWJiabin Wang
Jiabin Wang
JLJianfei Long
Jianfei Long
JMJianchao Mu
Jianchao Mu
HDHaoye Deng
Haoye Deng
Cong Feng QiaoCong Feng Qiao
Cong Feng Qiao
To enhance the accuracy of micro-Newton thrust measurements via a torsion pendulum, addressing microgravity coupling effects caused by platform tilt and pendulum mass eccentricity is crucial. This study focuses on analyzing and minimizing these effects by alleviating reference surface tilt and calibrating the center of mass during thrust measurements. The study introduced analysis techniques and compensation measures. It first examined the impact of reference tilt and center of mass eccentricity on the stiffness and compliance of the torsion pendulum by reconstructing its dynamic model. Simscape Multibody was initially employed for numerical analysis to assess the dynamic coupling effects of the tilted pendulum. The results showed the influence of reference tilt on the stiffness and compliance of the torsion pendulum through simulation. An inverted pendulum was developed to amplify the platform’s tilt angle for microgravity drag-free control. Center of mass calibration can identify the gravity coupling caused by the center of mass position. Based on the displacement signal from the capacitive sensor located at the end of the inverted pendulum, which represents the platform’s tilt angle, the pendulum’s vibration at 0.1 mHz was reduced from 5.7 μm/Hz1/2 to 0.28 μm/Hz1/2 by adjusting the voltage of piezoelectric actuator. Finally, a new two-stage torsion pendulum structure was proposed to decouple the tilt coupling buried in both pitch and roll angle. The study utilized theoretical models, numerical analysis, and experimental testing to validate the analysis methods and compensation measures for microgravity coupling effects in torsion pendulums. This led to a reduction in low-frequency noise caused by ground vibrations and thermal strains, ultimately improving the micro-Newton thrust measurement accuracy of the torsion pendulum through the platform’s drag-free control.

1 January 2018 in Acta Physica Sinica
Verified
Journal Article
Closed access
PDF file
LJLong Jian-Fei
Long Jian-Fei
ZTZhang Tian-Ping
Zhang Tian-Ping
YWYang Wei
Yang Wei
SMSun Ming-Ming
Sun Ming-Ming
JYJia Yan-Hui
Jia Yan-Hui
LMLiu Ming-Zheng
Liu Ming-Zheng
离子推力器推力密度分布对航天器轨道维持和修正具有重要影响.采用粒子模拟-蒙特卡罗碰撞方法模拟束流等离子体输运过程,分析束流多组分粒子喷出数量和速度等微观参数,并计算得到单孔束流推力,结合放电室出口等离子体密度分布,进一步对推力密度分布特性分析,最后开展实验验证.研究结果显示:束流中单价离子、双荷离子以及交换电荷离子的推力贡献比分别为84.63%,15.35%和1.82%,可见推力主要来源于束流中的单价离子和双荷离子,交换电荷离子对推力贡献很小;推力密度分布具有较好的中心轴对称性,从推力器中心沿着径向先快速下降后趋于缓慢;与实验结果对比,经验模型相对误差约为4.1%,数值模型相对误差约为2.8%,相比经验模型,数值模型具有更好的准确性.研究结果可为离子推力器推力密度分布均匀性等优化提供参考.

2 June 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JWJiabin Wang
Jiabin Wang
JLJianfei Long
Jianfei Long
JXJiawen Xu
Jiawen Xu
MWMingshan Wu
Mingshan Wu
LCLinxiao Cong
Linxiao Cong
NGNing Guo
Ning Guo
Sub-micro-Newton thrusters on space satellites are widely used in spaceborne gravitational wave detection, making accurate measurement of micro-thrust-generated thrust essential. Moreover, micro-propulsion systems often exhibit substantial mass, posing challenges for thrust measurement. This research prompted the development of a sub-micro-thrust measurement device based on the inverted pendulum principle, which with-stands 8 kg loads and boasts a large thrust-to-weight ratio exceeding 109. Experimental results demonstrate that adjusting the stiffness of the inverted pendulum can effectively enhance the resolution of the device. Piecewise constant signal (PCS) thrust force was introduced, and the nonlinear total variation denoising (TVD) algorithm method was adopted for signal denoising. It is validated that thrust measurement in the range of 0–261 μN is achieved with a minimum resolution of 24 nN. The device design and stiffness adjustment method proposed in this paper, as well as the data denoising method utilized, greatly enhance the thrust resolution measurement. This approach enables the development of an accurate micro-thrust model for spaceborne gravitational wave detection missions while simultaneously offering a novel solution for sub-micro-newton-level thrust measurement under heavy load conditions.

5 December 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JWJiabin Wang
Jiabin Wang
JLJianfei Long
Jianfei Long
XWXiaolei Wang
Xiaolei Wang
YWYing Wang
Ying Wang
SJSujin Ji
Sujin Ji
NGNing Guo
Ning Guo
This study introduces a new closed-loop dynamic micro-thrust measurement method based on torsional pendulum is proposed, addressing the poor real-time performance and insufficient precision inherent in traditional open-loop techniques that rely on extreme displacement values to estimate thrust. This method achieves PID closed-loop control through electromagnetic force compensation, tracking the thrust to be measured in real-time. The measurement results are directly inverted from the compensation force. Experimental results show that the dynamic thrust of the electromagnetic calibration system within 0.8 Hz is highly consistent with the calibration results of a high-precision balance with R2 = 0.99895. In closed-loop mode, the phase lag for 20 μN dynamic thrust measurement is only 0.5425°, with a root mean square error as low as 1.82%. The system’s expanded uncertainty is 1.79% below the intrinsic frequency of 11.57 mHz, providing a reliable ground-based verification solution for spacecraft drag-free control and high-frequency dynamic thrust measurement.

13 July 2023 in Plasma Science and Technology
Verified
Journal Article
Closed access
MSMingming Sun
Mingming Sun
JLJianfei Long
Jianfei Long
JCJuanjuan Chen
Juanjuan Chen
WYWei Yang
Wei Yang
WGWeilong Guo
Weilong Guo
XCXinwei Chen
Xinwei Chen
In view of the high cost caused by the 1:1 lifetime verification test of ion thrusters, the lifetime acceleration test should be considered. This work uses the PIC-MCC (Particle-in-Cell Monte-Carlo Collision) method to analyze the five failure factors that lead to the failure of the accelerator grid of a 30 cm diameter ion thruster under the working mode of 5 kW. Meanwhile, the acceleration stress levels corresponding to different failure factors are obtained. The results show that background pressure has the highest stress level on the grid’s erosion. The accelerator grid aperture’s mass sputtering rate under the rated vacuum degree (1 × 10−4 Pa) of 5 kW work mode is 8.78 times that of the baseline vacuum degree (1 × 10−6 Pa), and the mass sputtering rate under worse vacuum degree (5 × 10−3 Pa) is 5.08 times that of 1 × 10−4 Pa. Under the influence of the other four failure factors, namely, the voltage of the accelerator grid, upstream plasma density, the screen grid voltage and mass utilization efficiency, the mass sputtering rates of the accelerator grid hole are 2.32, 2.67, 1.98 and 2.51 times those of the accelerator grid hole under baseline condition, respectively. The ion sputtering results of two 30 cm diameter ion thrusters (both installed with new grids assembly) after working for 1000 h show that the mass sputtering rate of the accelerator grid hole under vacuum conditions of 5 × 10−3 Pa is 4.54 times that under the condition of 1 × 10−4 Pa, and the comparison error between simulation results and test results of acceleration stress is about 10%. In the subsequent ion thruster lifetime verification, the working vacuum degree can be adjusted according to the acceleration stress level of background pressure, so as to shorten the test time and reduce the test cost.

27 October 2023 in Vacuum
Verified
Journal Article
Closed access
JLJianfei Long
Jianfei Long
DHDan Huang
Dan Huang
MSMingming Sun
Mingming Sun
YCYe Cheng
Ye Cheng
JWJiabin Wang
Jiabin Wang
WYWei Yang
Wei Yang