Hao Zhang

Dr. Hao Zhang

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2021 in Materials
Verified
Journal Article
Open access
PDF file
Fangwen WuFangwen Wu
Fangwen Wu
SLShuo Liu
Shuo Liu
CXChengfeng Xue
Chengfeng Xue
KYKangkang Yang
Kangkang Yang
YFYanpeng Feng
Yanpeng Feng
HZHao Zhang
Hao Zhang
Perfobond rib (PBL) shear connectors, made up of the perforated steel plates with the penetrating rebars passing through the holes, are extensively adopted in steel-concrete composite structures for their excellent performance. The adequate understanding of mechanical properties for PBL connectors is of great significance for their reasonable design. In this study, a push out experiment, including 12 specimens with the parameters of concrete strength, diameter of penetrating rebars and the number of holes on perforated steel plate, was performed to explore the mechanical behavior of PBL connectors with steel fiber high strength concrete (SFHSC). The experimental results showed that the shear capacity of the PBL connectors increased with the increase in concrete strength, diameter of the penetrating rebars and the number of holes. Furthermore, a general prediction formula for the shear capacity of PBL connectors was developed, which considers the shear contribution of concrete dowels, concrete end-bearing, interfacial bonding between the perforated steel plates and concrete and the penetrating rebars as well as the enhancement effect of steel fibers. The prediction results of the equation are in good agreement with the experimental data and could provide a reference for the design of PBL connectors.

22 May 2021 in Materials
Verified
Journal Article
Open access
PDF file
Fangwen WuFangwen Wu
Fangwen Wu
WTWenlong Tang
Wenlong Tang
CXChengfeng Xue
Chengfeng Xue
GSGuorui Sun
Guorui Sun
YFYanpeng Feng
Yanpeng Feng
HZHao Zhang
Hao Zhang
In this research, high strength fiber reinforced concrete (HSFRC) was used to replace the normal strength concrete (NSC) in steel-concrete composite beams to improve their working performance, which might change the static performance of stud connectors. Firstly, push-out tests were conducted to investigation on the static performance of stud connectors in steel-HSFRC composite beams and compared with steel-NSC composite beams. Studs of 8 sizes, 13 mm, 16 mm, 19 mm and 22 mm in diameter and 80 mm and 120 mm in height were adopted to study the influence of stud dimension. The test phenomenon shown that the crack resistance of HSFRC was better than that of NSC, and there were some splitting cracks on NSC slabs whereas no visible cracks on HSFRC slabs when specimens failed. Next, the load-slip curves of studs were analyzed and a typical load-slip curve was proposed which was divided into four stages. In addition, the effects of test parameters were analyzed according to the characteristic points of load-slip curve. Compared with NSC slab, HSFRC slab could provide greater restraining force to the studs, which improved the shear capacity and stiffness of studs while suppressed the ductility of studs. The shear capacity, stiffness and ductility of studs would significantly increase with the increasement of stud diameter and the studs with large diameter were more suitable for steel-HSFRC composite beams. The stud height had no obvious influence on the static performance of studs. Finally, based on the test results, the empirical formulas for load-slip curve and shear capacity of stud connectors embedded in HSFRC were developed which considered the influence factors more comprehensively and had better accuracy and applicability than previous formulas.

30 January 2022 in Materials
Verified
Journal Article
Open access
PDF file
HZHao Zhang
Hao Zhang
ZZZhixin Zhong
Zhixin Zhong
JDJunmiao Duan
Junmiao Duan
JYJianke Yang
Jianke Yang
ZZZhichao Zheng
Zhichao Zheng
GLGuangxun Liu
Guangxun Liu
The damage identification method based on macro-strain modality has shown good results for large-span flexible bridges. However, medium- and small-span bridges have a high stiffness, and the axle system is embodied. The strong time-varying vibration characteristics, coupled with the non-stationary characteristics of vehicle loads, make it difficult to accurately determine the stable strain modes of such bridges. To solve this problem, a damage localization index in the form of an amplitude vector matrix of the mutual energy density spectrum based on macro-strain was constructed using wavelet transform de-noising and reconstruction technology and cross-correlation function. The macro-static strain and macro-dynamic strain data obtained from a vehicle–bridge coupling experiment were reconstructed through wavelet transform, and the factors influencing the damage indices were analyzed. The results showed that the proposed indicators could help realize an accurate damage localization for medium- and small-span bridge systems with different damage degrees under the action of vehicle–bridge coupling.

20 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
HZHao Zhang
Hao Zhang
GLGuangxun Liu
Guangxun Liu
JDJunmiao Duan
Junmiao Duan
GLGuangxun Liu
Guangxun Liu
JHJunhai Hu
Junhai Hu
The real-time monitoring of the flow environment parameters, such as flow velocity and direction, helps to accurately analyze the effect of water scour and provide technical support for the maintenance of pier and abutment foundations in water. Based on the principle of the Fiber Brag Grating sensor, a sensor for monitoring the flow velocity and direction in real-time is designed in this paper. Meanwhile, the theoretical calculation formulas of flow velocity and direction are derived. The structural performance of the sensor is simulated and analyzed by finite element analysis. The performance requirements of different parts of the sensor are clarified. After a sample of the sensor is manufactured, calibration experiments are conducted to verify the function and test the accuracy of the sensor, and the experimental error is analyzed. The experimental results indicate that the sensor designed in this paper achieves a high accuracy for the flow with a flow velocity of 0.05–5 m/s and the flow velocity monitoring error is kept within 7%, while the flow direction monitoring error is kept within 2°. The sensor can meet the actual monitoring requirements of the structures in water and provide reliable data sources for water scour analysis.

20 February 2026 in Journal of Civil Structural Health Monitoring
Verified
Journal Article
Closed access
PDF file
JLJian-An Li
Jian-An Li
DFDongming Feng
Dongming Feng
HZHao Zhang
Hao Zhang

28 October 2026 in Buildings
Verified
Journal Article
Open access
PDF file
QZQianyi Zhao
Qianyi Zhao
HZHao Zhang
Hao Zhang
TWTengyi Wang
Tengyi Wang
Reliable measurements of local displacement provide useful information for slope monitoring near buildings. Displacement reconstruction from low-cost MEMS acceleration is affected by gravity projection, sensor bias, and anomalous observations. This study presents a MEMS–LoRa sensing node and an anomaly-aware state estimation framework (LPD-RSE) for short-duration displacement reconstruction. The model accounts for gravity projection and estimates displacement, velocity, acceleration, residual bias, and bias-drift rate. Residual occupancy and robust slope criteria distinguish isolated spikes, persistent bias, and slowly varying drift before compensation and a robust extended Kalman filter update. Controlled platform experiments tested continuous 15 cm motion, intermittent 5 + 5 + 5 cm motion, and 15 cm motion with 30° and 45° installation inclination. Relative to commanded platform displacement, the maximum repeated-trial relative errors were 2.53% and 1.87% in the continuous and intermittent tests, respectively; the corresponding endpoint RMSE values were 0.325 and 0.206 cm. LPD-RSE produced the lowest endpoint RMSE among the four displacement reconstruction methods tested and limited rest period drift to 0.070 cm. The inclined tests showed larger errors. In the extended six-method comparison against an independent displacement reference, LPD-RSE yielded an endpoint RMSE of 0.1397 cm and a mean trajectory RMSE of 0.0775 cm. Paired tests characterized the uncertainty of the observed differences. These laboratory results support short-duration displacement reconstruction and suggest a potential role in monitoring ground movement near buildings.