Desiree Nadine Wussler

Dr. Desiree Nadine Wussler

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in Clinical Chemistry
Verified
Journal Article
Closed access
PDF file
JBJasper Boeddinghaus
Jasper Boeddinghaus
RTRaphael Twerenbold
Raphael Twerenbold
TNThomas Nestelberger
Thomas Nestelberger
PBPatrick Badertscher
Patrick Badertscher
WKWildi Karin
Wildi Karin
JPJiri Parenica
Jiri Parenica
BACKGROUND: Clinical performance of the novel high-sensitivity cardiac troponin I (Siemens-hs-cTnI-Centaur) assay is unknown. We aimed to clinically validate the Siemens-hs-cTnI-Centaur assay and develop 0/1-h and 0/2-h algorithms. METHODS: We enrolled patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction (AMI). Final diagnoses were centrally adjudicated by 2 independent cardiologists including all clinical information twice: first, using serial hs-cTnT (Roche-Elecsys, primary analysis); second, using hs-cTnI (Abbott-Architect, secondary analysis) measurements in addition to the clinically applied (hs)-cTn. Siemens-hs-cTnI-Centaur was measured at presentation, 1 h, and 2 h. The primary objective was a direct comparison of diagnostic accuracy, quantified by the area under the ROC curve (AUC), of Siemens-hs-cTnI-Centaur vs the 2 established hs-cTn assays (Roche-hs-cTnT-Elecsys, Abbott-hs-cTnI-Architect). Secondary objectives included the development of Siemens-hs-cTnI-Centaur-specific 0/1-h and 0/2-h algorithms. RESULTS: AMI was the final diagnosis in 318 of 1755 (18%) patients (using Roche-hs-cTnT-Elecsys for adjudication). The AUC at presentation for Siemens-hs-cTnI-Centaur was 0.94 (95% CI, 0.92–0.96) and comparable with 0.95 (95% CI, 0.93–0.97) for Roche-hs-cTnT-Elecsys and 0.93 (95% CI, 0.90–0.96) for Abbott-hs-cTnI-Architect. Applying the derived Siemens-hs-cTnI-Centaur 0/1-h algorithm to the validation cohort, 46% of patients were ruled out (sensitivity, 99.1%; 95% CI, 95.3–100), and 18% of patients were ruled in (specificity, 94.1%; 95% CI, 91.8–95.9). The Siemens-hs-cTnI-Centaur 0/2-h algorithm ruled out 55% of patients (sensitivity, 100%; 95% CI, 94.1–100), and ruled in 18% of patients (specificity, 96.0%; 95% CI, 93.1–97.9). Findings were confirmed in the secondary analyses using serial measurements of Abbott-hs-cTnI-Architect for adjudication. CONCLUSIONS: Diagnostic accuracy and clinical utility of the novel Siemens-hs-cTnI-Centaur assay are high and comparable with the established hs-cTn assays. ClinicalTrials.gov Identifier: NCT00470587

5 June 2018 in Circulation
Verified
Journal Article
Closed access
PBPatrick Badertscher
Patrick Badertscher
JBJasper Boeddinghaus
Jasper Boeddinghaus
RTRaphael Twerenbold
Raphael Twerenbold
TNThomas Nestelberger
Thomas Nestelberger
WKWildi Karin
Wildi Karin
NGNicolas Geigy
Nicolas Geigy

1 November 2018 in International Journal of Cardiology
Verified
Journal Article
Closed access
WKWildi Karin
Wildi Karin
HSH. Singeisen
H. Singeisen
RTR. Twerenbold
R. Twerenbold
PBP. Badertscher
P. Badertscher
DWDesiree Nadine Wussler
Desiree Nadine Wussler
CMC. Mueller
C. Mueller

4 January 2018 in European Journal of Heart Failure
Verified
Journal Article
Closed access
PDF file
TBTobias Breidthardt
Tobias Breidthardt
ZMZoraida Moreno-Weidmann
Zoraida Moreno-Weidmann
HUHeiko Uthoff
Heiko Uthoff
ZSZaid Sabti
Zaid Sabti
SASven Aeppli
Sven Aeppli
CMChristian Mueller
Christian Mueller

24 April 2018 in Circulation
Verified
Journal Article
Closed access
MGMaria Rubini Gimenez
Maria Rubini Gimenez
PBPatrick Badertscher
Patrick Badertscher
RTRaphael Twerenbold
Raphael Twerenbold
JBJasper Boeddinghaus
Jasper Boeddinghaus
TNThomas Nestelberger
Thomas Nestelberger
CMChristian Müller
Christian Müller

12 February 2022 in European Heart Journal: Acute Cardiovascular Care
Verified
Journal Article
Open access
PDF file
TKThomas E Kaier
Thomas E Kaier
RTRaphael Twerenbold
Raphael Twerenbold
PAPedro Lopez Ayala
Pedro Lopez Ayala
TNThomas Nestelberger
Thomas Nestelberger
JBJasper Boeddinghaus
Jasper Boeddinghaus
CNChristian Nickel
Christian Nickel
Cardiac myosin-binding protein C (cMyC) demonstrated high diagnostic accuracy for the early detection of non-ST-elevation myocardial infarction (NSTEMI). Its dynamic release kinetics may enable a 0/1h-decision algorithm that is even more effective than the ESC hs-cTnT/I 0/1 h rule-in/rule-out algorithm. In a prospective international diagnostic study enrolling patients presenting with suspected NSTEMI to the emergency department, cMyC was measured at presentation and after 1 h in a blinded fashion. Modelled on the ESC hs-cTnT/I 0/1h-algorithms, we derived a 0/1h-cMyC-algorithm. Final diagnosis of NSTEMI was centrally adjudicated according to the 4th Universal Definition of Myocardial Infarction. Among 1495 patients, the prevalence of NSTEMI was 17%. The optimal derived 0/1h-algorithm ruled-out NSTEMI with cMyC 0 h concentration below 10 ng/L (irrespective of chest pain onset) or 0 h cMyC concentrations below 18 ng/L and 0/1 h increase <4 ng/L. Rule-in occurred with 0 h cMyC concentrations of at least 140 ng/L or 0/1 h increase ≥15 ng/L. In the validation cohort (n = 663), the 0/1h-cMyC-algorithm classified 347 patients (52.3%) as ‘rule-out’, 122 (18.4%) as ‘rule-in’, and 194 (29.3%) as ‘observe’. Negative predictive value for NSTEMI was 99.6% [95% confidence interval (CI) 98.9–100%]; positive predictive value 71.1% (95% CI 63.1–79%). Direct comparison with the ESC hs-cTnT/I 0/1h-algorithms demonstrated comparable safety and even higher triage efficacy using the 0h-sample alone (48.1% vs. 21.2% for ESC hs-cTnT-0/1 h and 29.9% for ESC hs-cTnI-0/1 h; P < 0.001). The cMyC 0/1h-algorithm provided excellent safety and identified a greater proportion of patients suitable for direct rule-out or rule-in based on a single measurement than the ESC 0/1h-algorithm using hs-cTnT/I. ClinicalTrials.gov number, NCT00470587.