Tjahjo Adiprabowo

Dr. Tjahjo Adiprabowo

National Taiwan University of Science and Technology (Taiwan Tech)
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
APAriana Purnomo
Ariana Purnomo
DLDing-Bing Lin
Ding-Bing Lin
Tjahjo AdiprabowoTjahjo Adiprabowo
Tjahjo Adiprabowo
Willy Fitra HendriaWilly Fitra Hendria
Willy Fitra Hendria
During the pandemic of coronavirus disease-2019 (COVID-19), medical practitioners need non-contact devices to reduce the risk of spreading the virus. People with COVID-19 usually experience fever and have difficulty breathing. Unsupervised care to patients with respiratory problems will be the main reason for the rising death rate. Periodic linearly increasing frequency chirp, known as frequency-modulated continuous wave (FMCW), is one of the radar technologies with a low-power operation and high-resolution detection which can detect any tiny movement. In this study, we use FMCW to develop a non-contact medical device that monitors and classifies the breathing pattern in real time. Patients with a breathing disorder have an unusual breathing characteristic that cannot be represented using the breathing rate. Thus, we created an Xtreme Gradient Boosting (XGBoost) classification model and adopted Mel-frequency cepstral coefficient (MFCC) feature extraction to classify the breathing pattern behavior. XGBoost is an ensemble machine-learning technique with a fast execution time and good scalability for predictions. In this study, MFCC feature extraction assists machine learning in extracting the features of the breathing signal. Based on the results, the system obtained an acceptable accuracy. Thus, our proposed system could potentially be used to detect and monitor the presence of respiratory problems in patients with COVID-19, asthma, etc.

11 July 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
APAloysius Adya Pramudita
Aloysius Adya Pramudita
DLDing-Bing Lin
Ding-Bing Lin
SHSung-Nien Hsieh
Sung-Nien Hsieh
EAErfansyah Ali
Erfansyah Ali
HRHarfan Hian Ryanu
Harfan Hian Ryanu
APAriana Purnomo
Ariana Purnomo
The presence of an obstacle in detecting respiration vital signs using a radar system does not only exhibit attenuation and phase shift effects on the radar signal but also causes additional beat frequencies to appear beside those from the target. When a conventional FMCW radar system detects the peak of the received signal spectrum as a beat frequency, this will give an error of detection. The respiratory vital signs will then be undetectable. A method to overcome this obstacle problem is needed. Therefore the implementation of the FMCW radar system in detecting respiratory vital signs behind the wall can be realized. In this paper, a method to deal with the previously mentioned problem is proposed. The proposed method consists of a method for identifying the obstacle response. Then the results are used to eliminate the beat frequency that arises from the obstacle structure, and therefore the signal to clutter ratio (SCR) can be improved. Furthermore, the method is combined with the phase detection method, which is applied to extract the Doppler response related to the target respiratory vital signs. The weighting process by elaborating cross correlation is also employed for minimizing clutter from other objects reflection under debris. A laboratory experiment by developing an FMCW radar system with a 24 GHz frequency operation was performed in this research. The proposed detection method was elaborated in the post-processing of the radar system. The experiment result demonstrates that the proposed method is capable of eliminating the effect of the wall and successfully extracting the respiration vital sign pattern.

6 July 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
APAloysius Adya Pramudita
Aloysius Adya Pramudita
DLDing-Bing Lin
Ding-Bing Lin
ADAzizka Ayu Dhiyani
Azizka Ayu Dhiyani
HRHarfan Hian Ryanu
Harfan Hian Ryanu
Tjahjo AdiprabowoTjahjo Adiprabowo
Tjahjo Adiprabowo
EYErfansyah Ali Yudha
Erfansyah Ali Yudha
The displacement on the bridge structure is an essential parameter in identifying the bridge structure’s health. The non-contact measurement method is preferable in practice, and the radar system is potentially employed for developing displacement measurement technology. Frequency Modulated Continuous Wave (FMCW) radar has a feature for detecting the target location. However, estimating the small displacement in the bridge structure requires extensive bandwidth to reach the proper resolution. The problem of obtaining the required resolution, and adopting the decrease in accuracy due to several possible radar placements during measurement are addressed in this paper. The concept of bridge displacement measurement using a modified FMCW radar system is proposed. Phase information extraction is employed to reach the displacement detection resolution, and the radar elevation detection based on an inclinometer is equipped in the proposed radar system. The simulation and laboratory experiments were conducted by implementing the proposed radar system for detecting the displacement in the bridge model. The experiment results confirm that the proposed FMCW radar was able to estimate the bridge displacement and overcome the decreasing accuracy due to the radar elevation. The multi-point detection technique is also developed in the proposed radar and capable to capture the displacement profile over bridge span. The proposed FMCW system is then recommended as a radar system in developing a non-contact method for bridge displacement measurement and monitoring.

18 November 2021 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
Tjahjo AdiprabowoTjahjo Adiprabowo
Tjahjo Adiprabowo
DLDing-Bing Lin
Ding-Bing Lin
YZYou-Hao Zheng
You-Hao Zheng
YCYen-Hao Chen
Yen-Hao Chen
ZCZhuang Cheng-Yi
Zhuang Cheng-Yi
BTBo-Hung Tsai
Bo-Hung Tsai
In this article, a common-mode noise filter with a wideband suppressing and dual-band high absorbing common mode filter, which is called absorptive common-mode filter, is proposed. The filter is constructed by a reflective-type common-mode filter, a phase matching, and an absorber. It is composed of three layers with 14.98 mm × 9.585 mm. The broadband common-mode noise suppression can be achieved by positioning multiple transmission zeros. By using dual-band phase matching and an absorber, the dual-band absorption can be realized. The frequencies are in the range of 2.4 to 2.5 GHz and 5.17 to 5.33 GHz, respectively. The positioning of transmission zeros and absorption points at those frequencies leads to a high absorption efficiency. The simulation result shows that the common-mode suppression, which is below −10 dB, is from 2 to 11 GHz. The fractional bandwidth is 138%. The differential-mode signal keeps integrity in the range from DC to 12 GHz. The absorption efficiencies in the two frequency sections are 97% and 96%, respectively. The experiment results show only slight differences from the simulation results.

20 January 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Tjahjo AdiprabowoTjahjo Adiprabowo
Tjahjo Adiprabowo
DLDing-Bing Lin
Ding-Bing Lin
TWTse-Hsuan Wang
Tse-Hsuan Wang
APAriana Purnomo
Ariana Purnomo
APAloysius Adya Pramudita
Aloysius Adya Pramudita
The measurement of heartbeat rate and breathing rate for patients with sensitive skin, such as skin with burns, is very difficult to do, especially if the number of patients is large and medical personnel is limited. Therefore, this study seeks to propose a preliminary solution to this problem by proposing a device that can measure the vital signs of several people concurrently, especially the heartbeat rate and breathing rate, without attaching sensors to their skin. This is done using an FMCW (frequency-modulated continuous wave) radar that operates at 77–81 GHz. FMCW radar emits electromagnetic waves towards the chest of several targets and picks up the reflected waves. Then, using signal processing of these reflected waves, each target’s heartbeat rate and breathing rate can be obtained. Our experiment managed to perform concurrent detection for four targets. The experimental results are between 52 and 82 beats per minute for the heartbeat rates and between 10 and 35 breaths per minute for the breathing rates of four targets. These results are in accordance with normal heartbeat rate and normal breathing rate; thus, our research succeeded in proposing a preliminary solution to this problem.

22 June 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DLDing-Bing Lin
Ding-Bing Lin
MWMei-Hui Wang
Mei-Hui Wang
APAloysius Adya Pramudita
Aloysius Adya Pramudita
Tjahjo AdiprabowoTjahjo Adiprabowo
Tjahjo Adiprabowo
An ultra-wideband common-mode (CM) filter for a gigahertz (GHz) data rate signal is proposed in this paper. The proposed filter was designed only on the printed circuit board (PCB) ground plane; no additional components wererequired. We took advantage of producing second-order transmission zero by an asymmetrical magnified coupled DGS to extend the suppression bandwidth. Full-wave simulations and equivalent circuit models of the DGS resonator were established to predict the suppression performance. The measured differential-mode insertion loss (Sdd21) from direct current (DC) to 12.35 GHz was obtained within the −3 dB definitionin the frequency domain. The CM noise was suppressed by more than10 dB in the frequency range from 2.9 GHz to 16.2 GHz. The fractional bandwidth (FBW) reached 139.3%. The proposed filter blocked 62.3% of the CM noise magnitude in the time domain measurement. In addition, the eye diagram measurement proved that good transmission quality was maintained. The proposed filter can be widely implemented to reduce electromagnetic interference (EMI) in radio frequency (RF) andWi-Fi (wireless fidelitystandard) 5 and 6E wireless communication applications.