Predictive control offers many advantages such as simple design and a systematic way to handle constraints. Model predictive control (MPC) belongs to predictive control, which uses a model of the system for predictions used in predictive control. A major drawback of MPC is the dependence of its performance on the model of the system. Any discrepancy between the system model and actual plant behavior will greatly affect the performance of the MPC. Recently, model-free approaches have been gaining attention because they are not dependent on the system model parameters. To obtain the advantages of both a model-free approach and predictive control, model-free predictive control (MFPC) is being explored and reported in the literature for different applications such as power electronics and electric drives. This paper presents an overview of model-free predictive control. A comprehensive review of the application of MFPC in power converters, electric drives, power systems, and microgrids is presented in this paper. Moreover, challenges, opportunities, and emerging trends in MFPC are also discussed in this paper.
Islanded microgrids have low inertia due to a large penetration of non-inertial inverter based power sources. In such systems, the primary frequency controller (PFC) faces the issue of a higher rate of change of frequency (RoCoF) and large peak frequency deviation in case of a sudden change in load or generation loss. The frequency control becomes more challenging as the variation in the frequency of different sources is not synchronized. This paper proposes a model for frequency dynamics in an islanded microgrid comprised of both inverter based distributed generators (DGs) and synchronous generators (SGs). The model is developed considering the asynchronous variation of frequency among the SGs. Based on the developed model, a novel disturbance compensation-based PFC is proposed. The PFC controls the reference power of a battery energy storage system (BESS) which is operated in grid-following mode and compensates for the power imbalance in the microgrid. The performance of the proposed model and the PFC is verified using Typhoon real-time hardware-in-the-loop simulation.
30 April 2021 in IEEE Transactions on Energy Conversion
Islanded microgrids have low inertia due to large penetration of non-inertial inverter based power sources. Such systems are prone to instability due to a higher rate of change of frequency (RoCoF) and large peak frequency deviation in case of a sudden load change or generation loss. This paper proposes a novel fast frequency control method for an islanded microgrid comprised of both inverter based distributed generators (DGs) and synchronous generators (SGs). The frequency controller estimates the power imbalance during the transient and compensates for it through a battery energy storage system (BESS). For the estimation of the power imbalance, an approximated linear model of the microgrid is developed considering multiple SGs operating in parallel. To transfer the compensated power from BESS to SGs, and also to maintain the state of charge (SoC) of the BESS, a SoC balancing control method is presented which is implemented by controlling the biased frequency of the SGs. The performance of the proposed frequency control method is verified using Typhoon real-time hardware-in-the-loop simulator.
As the share of power converter-based renewable energy sources (RESs) is high, a microgrid, in islanded mode, is more vulnerable to frequency instability due to (1) sudden power imbalance and (2) low inertia. One of the most common approaches to address this issue is to provide virtual inertia to the system by appropriately controlling the grid-side converter of the RESs. However, the primary frequency controller (PFC) presented in this paper focuses on the fast compensation of power imbalance without adding inertia to the system. The proposed method is based on estimating the real-time power imbalance caused by a disturbance and compensating it using multiple small-scale distributed battery energy storage systems (BESSs). The power imbalance is estimated by observing the initial rate of change of frequency (RoCoF) following a disturbance. Based on the estimated power imbalance and the rating of the BESSs, the reference power for the BESSs is determined. The BESSs are controlled in grid-following mode to compensate for the power imbalance. The performance of the proposed PFC is verified using a Typhoon real-time simulator for various scenarios and is compared with the conventional virtual synchronous generator (VSG) controller.