Wajiha Shireen

Dr. Wajiha Shireen

1. Department of Engineering Technology, University of Houston, Houston, TX 77004, USA</br> 2. Department of Electrical and Computer Engineering, University of Houston, Houston, TX 77004, USA
+1
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2014 in Renewable Energy
Verified
Journal Article
Closed access
PGP. Goli
P. Goli
Wajiha ShireenWajiha Shireen
Wajiha Shireen

14 July 2022 in Energies
Verified
Journal Article
Open access
PDF file
MNMuhammad Nauman
Muhammad Nauman
Wajiha ShireenWajiha Shireen
Wajiha Shireen
AHAmir Hussain
Amir Hussain
Predictive control offers many advantages such as simple design and a systematic way to handle constraints. Model predictive control (MPC) belongs to predictive control, which uses a model of the system for predictions used in predictive control. A major drawback of MPC is the dependence of its performance on the model of the system. Any discrepancy between the system model and actual plant behavior will greatly affect the performance of the MPC. Recently, model-free approaches have been gaining attention because they are not dependent on the system model parameters. To obtain the advantages of both a model-free approach and predictive control, model-free predictive control (MFPC) is being explored and reported in the literature for different applications such as power electronics and electric drives. This paper presents an overview of model-free predictive control. A comprehensive review of the application of MFPC in power converters, electric drives, power systems, and microgrids is presented in this paper. Moreover, challenges, opportunities, and emerging trends in MFPC are also discussed in this paper.

25 October 2024 in Energies
Verified
Journal Article
Open access
PDF file
DKDileep Kumar
Dileep Kumar
Wajiha ShireenWajiha Shireen
Wajiha Shireen
NRNanik Ram
Nanik Ram
Over the past few decades, wind energy has expanded to become a widespread, clean, and sustainable energy source. However, integrating offshore wind energy with the onshore AC grids presents many stability and control challenges that hinder the reliability and resilience of AC grids, particularly during faults. To address this issue, current grid codes require offshore wind farms (OWFs) to remain connected during and after faults. This requirement is challenging because, depending on the fault location and power flow direction, DC link over- or under-voltage can occur, potentially leading to the shutdown of converter stations. Therefore, this necessitates the proper understanding of key technical concepts associated with the integration of OWFs. To help fill the gap, this article performs an in-depth investigation of existing alternating current fault ride through (ACFRT) techniques of modular multilevel converter-based high-voltage direct current (MMC-HVDC) for OWFs. These techniques include the use of AC/DC choppers, flywheel energy storage devices (FESDs), power reduction strategies for OWFs, and energy optimization of the MMC. This article covers both scenarios of onshore and offshore AC faults. Given the importance of wind turbines (WTs) in transforming wind energy into mechanical energy, this article also presents an overview of four WT topologies. In addition, this article explores the advanced converter topologies employed in HVDC systems to transform three-phase AC voltages to DC voltages and vice versa at each terminal of the DC link. Finally, this article explores the key stability and control concepts, such as small signal stability and large disturbance stability, followed by future research trends in the development of converter topologies for HVDC transmission such as hybrid HVDC systems, which combine current source converters (CSCs) and voltage source converters (VSCs) and diode rectifier-based HVDC (DR-HVDC) systems.

16 February 2022 in Smart Cities
Verified
Journal Article
Open access
PDF file
Preetham GoliPreetham Goli
Preetham Goli
KJKiran Jasthi
Kiran Jasthi
SGSRINIVASA RAO GAMPA
SRINIVASA RAO GAMPA
DDDebapriya Das
Debapriya Das
Wajiha ShireenWajiha Shireen
Wajiha Shireen
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
In this study, a two-stage methodology based on the energy savings gained by optimal network reconductoring was developed for the sizing and allocation of electric vehicle (EV) charging load at the residential locations in urban distribution systems. During the first stage, the Flower Pollination Algorithm (FPA) was applied to minimize the annual energy losses of the radial distribution system through optimum network reconductoring. A multi-objective function was formulated to minimize investment, peak loss, and annual energy loss costs at different load factors. The results obtained with the flower pollination algorithm were compared with the particle swarm optimization algorithm. In the second stage, a simple heuristic procedure was developed for the sizing and allocation of EV charging load at every node of the distribution system utilizing part of the annual energy savings obtained by optimal network reconductoring. The number of electric cars, electric bikes, and electric scooters that can be charged at every node was computed while maintaining the voltage and branch current constraints. The simulation results were demonstrated on 123 bus and 51 bus radial distribution networks to validate the effectiveness of the proposed methodology.

30 March 2021 in IEEE Access
Verified
Journal Article
Open access
AHAmir Hussain
Amir Hussain
Wajiha ShireenWajiha Shireen
Wajiha Shireen
Islanded microgrids have low inertia due to a large penetration of non-inertial inverter based power sources. In such systems, the primary frequency controller (PFC) faces the issue of a higher rate of change of frequency (RoCoF) and large peak frequency deviation in case of a sudden change in load or generation loss. The frequency control becomes more challenging as the variation in the frequency of different sources is not synchronized. This paper proposes a model for frequency dynamics in an islanded microgrid comprised of both inverter based distributed generators (DGs) and synchronous generators (SGs). The model is developed considering the asynchronous variation of frequency among the SGs. Based on the developed model, a novel disturbance compensation-based PFC is proposed. The PFC controls the reference power of a battery energy storage system (BESS) which is operated in grid-following mode and compensates for the power imbalance in the microgrid. The performance of the proposed model and the PFC is verified using Typhoon real-time hardware-in-the-loop simulation.

30 April 2021 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
AHAmir Hussain
Amir Hussain
SHShamim Hasan
Shamim Hasan
SPSumit Patil
Sumit Patil
Wajiha ShireenWajiha Shireen
Wajiha Shireen
Islanded microgrids have low inertia due to large penetration of non-inertial inverter based power sources. Such systems are prone to instability due to a higher rate of change of frequency (RoCoF) and large peak frequency deviation in case of a sudden load change or generation loss. This paper proposes a novel fast frequency control method for an islanded microgrid comprised of both inverter based distributed generators (DGs) and synchronous generators (SGs). The frequency controller estimates the power imbalance during the transient and compensates for it through a battery energy storage system (BESS). For the estimation of the power imbalance, an approximated linear model of the microgrid is developed considering multiple SGs operating in parallel. To transfer the compensated power from BESS to SGs, and also to maintain the state of charge (SoC) of the BESS, a SoC balancing control method is presented which is implemented by controlling the biased frequency of the SGs. The performance of the proposed frequency control method is verified using Typhoon real-time hardware-in-the-loop simulator.