Idris Azeez Olayiwola

Dr. Idris Azeez Olayiwola


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
AIAzeez Idris
Azeez Idris
EOEkemena O. Oseghe
Ekemena O. Oseghe
TMTitus Msagati
Titus Msagati
Alex KuvaregaAlex Kuvarega
Alex Kuvarega
UFUsisipho Feleni
Usisipho Feleni
Bhekie B MambaBhekie B Mamba
Bhekie B Mamba
Graphitic carbon nitride (g-C3N4) is a two-dimensional conjugated polymer that has attracted the interest of researchers and industrial communities owing to its outstanding analytical merits such as low-cost synthesis, high stability, unique electronic properties, catalytic ability, high quantum yield, nontoxicity, metal-free, low bandgap energy, and electron-rich properties. Notably, graphitic carbon nitride (g-C3N4) is the most stable allotrope of carbon nitrides. It has been explored in various analytical fields due to its excellent biocompatibility properties, including ease of surface functionalization and hydrogen-bonding. Graphitic carbon nitride (g-C3N4) acts as a nanomediator and serves as an immobilization layer to detect various biomolecules. Numerous reports have been presented in the literature on applying graphitic carbon nitride (g-C3N4) for the construction of electrochemical sensors and biosensors. Different electrochemical techniques such as cyclic voltammetry, electrochemiluminescence, electrochemical impedance spectroscopy, square wave anodic stripping voltammetry, and amperometry techniques have been extensively used for the detection of biologic molecules and heavy metals, with high sensitivity and good selectivity. For this reason, the leading drive of this review is to stress the importance of employing graphitic carbon nitride (g-C3N4) for the fabrication of electrochemical sensors and biosensors.

8 March 2019 in Biosensors
Verified
Journal Article
Open access
PDF file
AIAzeez Idris
Azeez Idris
Nonhlangabezo MABUBANonhlangabezo MABUBA
Nonhlangabezo MABUBA
Omotayo ArotibaOmotayo Arotiba
Omotayo Arotiba
An electrochemical immunosensor for the quantification of carcinoembryonic antigen (CEA) using a nanocomposite of polypropylene imine dendrimer (PPI) and carbon nanodots (CNDTs) on an exfoliated graphite electrode (EG) is reported. The carbon nanodots were prepared by pyrolysis of oats. The nanocomposites (PPI and CNDTs) were characterized using X-ray powder diffraction (XRD), Raman spectroscopy, Fourier transform infrared spectroscopy (FTIR), high-resolution transmission electron microscopy (HRTEM) and scanning electron microscopy (SEM). The proposed immunosensor was prepared on an exfoliated graphite electrode sequentially by drop coating CNDTs, the electrodeposition of G2-PPI (generation 2 poly (propylene imine) dendrimer), the immobilization of anti-CEA on the modified electrode for 80 min at 35 °C, and dropping of bovine serum albumin (BSA) to minimize non-specific binding sites. Cyclic voltammetry was used to characterize each stage of the fabrication of the immunosensor. The proposed immunosensor detected CEA within a concentration range of 0.005 to 300 ng/mL with a detection limit of 0.00145 ng/mL by using differential pulse voltammetry (DPV). The immunosensor displayed good stability and was also selective in the presence of some interference species such as ascorbic acid, glucose, alpha-fetoprotein, prostate-specific antigen and human immunoglobulin. Furthermore, the fabricated immunosensor was applied in the quantification of CEA in a human serum sample, indicating its potential for real sample analysis.

17 July 2023 in Electrocatalysis
Verified
Journal Article
Open access
PDF file
AIAzeez Idris
Azeez Idris
BOBenjamin Orimolade
Benjamin Orimolade
LDLynn Dennany
Lynn Dennany
BMBhekie Mamba
Bhekie Mamba
SAShohreh Azizi
Shohreh Azizi
MMMalik Maaza
Malik Maaza
This review focuses on monitoring selected organic contaminants utilising an electrochemistry technique due to intrinsic benefits such as simplicity, portability, cost, and improved sensitivity. Because the presence of organic pollutants in water causes a variety of health issues such as tumour, headaches, tiredness, and developmental abnormalities, it is critical to explore an effective approach to quantifying these contaminants in various matrices. Although remarkable results have been documented in the use of conventional techniques in the quantification of organic pollutants, owing to high costs, longer pre-concentration steps and analysis times, high power consumption, and the need for sophisticated skilled personnel, their applications for monitoring organic pollutants on-site have been hampered. The electrochemistry approach has emerged to address the difficulties that have hindered the use of traditional approaches for quantifying organic contaminants in water. Thus, the purpose of this review is to examine the concept of employing electrochemistry techniques to determine organic contaminants in various matrixes, and various recommendations for future research have been highlighted. Graphical Abstract This diagram illustrates the steps involved in creating a sensor utilising nanomaterial and connected to a three-electrode system. The nanomaterial is immobilised onto the surface of the working electrode. A suitable potentiostat is then employed to generate the current signal of the reaction between the sensor and the desired analyte.

27 January 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
AIAzeez Idris
Azeez Idris
SASeyi Philemon Akanji
Seyi Philemon Akanji
BOBenjamin Olawale
Benjamin Olawale
FOFoluke Omobola Grace Olorundare
Foluke Omobola Grace Olorundare
SAShohreh Azizi
Shohreh Azizi
MMMalik Maaza
Malik Maaza
The endless development in nanotechnology has introduced new vitality in device fabrication including biosensor design for biomedical applications. With outstanding features like suitable biocompatibility, good electrical and thermal conductivity, wide surface area and catalytic activity, nanomaterials have been considered excellent and promising immobilisation candidates for the development of high-impact biosensors after they emerged. Owing to these reasons, the present review deals with the efficient use of nanomaterials as immobilisation candidates for biosensor fabrication. These include the implementation of carbon nanomaterials—graphene and its derivatives, carbon nanotubes, carbon nanoparticles, carbon nanodots—and MXenes, likewise their synergistic impact when merged with metal oxide nanomaterials. Furthermore, we also discuss the origin of the synthesis of some nanomaterials, the challenges associated with the use of those nanomaterials and the chemistry behind their incorporation with other materials for biosensor design. The last section covers the prospects for the development and application of the highlighted nanomaterials.

3 July 2021 in Journal of Nanoparticle Research
Verified
Journal Article
Closed access
PDF file
AIAzeez Idris
Azeez Idris
PMPotlako J. Mafa
Potlako J. Mafa
EOEkemena O. Oseghe
Ekemena O. Oseghe
TMTitus A. M. Msagati
Titus A. M. Msagati
UFUsisipho Feleni
Usisipho Feleni
BMBhekie B. Mamba
Bhekie B. Mamba

2 February 2024 in ChemistrySelect
Verified
Journal Article
Open access
VOViola Onyinye Okechukwu
Viola Onyinye Okechukwu
AIAzeez Idris
Azeez Idris
EUEseoghene H. Umukoro
Eseoghene H. Umukoro
SAShohreh Azizi
Shohreh Azizi
MMMalik Maaza
Malik Maaza
Gas sensors are crucial in various industries like chemicals, food processing, pharmaceuticals, health monitoring through breath analysis, as well as in household and environmental monitoring to ensure human safety. Chemo‐resistive gas sensors based on metal oxides convert gas information into electrical signals by interacting with adsorption and desorption processes. For metal oxide semiconductor gas sensors, sensitivity and selectivity enhancements are achieved through doping, functionalization, composite formations, heterojunction creation, and morphological adjustments. The formation of heterojunctions notably boosts the efficacy of the sensing material, leveraging synergistic effects to reinforce adsorption rates, catalytic activity acceleration, and the depletion interface for electrons and holes. Over the past few decades, nanomaterials have played a critical role in gas sensing applications. They have enabled the detection of a wide array of harmful and polluting gases, as well as volatile organic compounds serving as disease biomarkers. Additionally, incorporating heterostructure nanomaterials into heterojunctions significantly impacts sensing performance and detection speed. This review discussed various types of gas sensing devices, categorizing them based on the sensing elements employed, each possessing its own set of unique advantages and disadvantages. Nevertheless, the review underscored the importance of several key parameters and factors that influence the performance of gas sensors. Additionally, recent advancements in the utilization of nanomaterial composites for gas sensor applications, particularly in the detection of gases such as ammonia, hydrogen sulphide, and sulphur dioxide vapours, were discussed. Furthermore, the review highlights recent research endeavours and fundamental parameters, including sensitivity, detection limits, selectivity, response times, and recovery times.