Ajalawit Chantaveerod

Dr. Ajalawit Chantaveerod

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 June 2021 in Sensors
Verified
Journal Article
Open access
PDF file
ACAjalawit Chantaveerod
Ajalawit Chantaveerod
KWKampol Woradit
Kampol Woradit
Charernkiat PochaiyaCharernkiat Pochaiya
Charernkiat Pochaiya
It is well-known that the analog FM radio channels in suburban areas are underutilized. Before reallocating the unused channels for other applications, a regulator must analyze the spectrum occupancy. Many researchers proposed the spectrum occupancy models to find vacant spectrum. However, the existing models do not analyze each channel individually. This paper proposes an approach consisting (i) a spectrum measurement strategy, (ii) an appropriate decision threshold, and (iii) criteria for channel classification, to find the unused channels. The measurement strategy monitors each channel’s activity by capturing the power levels of the passband and the guardband separately. The decision threshold is selected depending on the monitored channel’s activity. The criteria classifies the channels based on the passband’s and guardband’s duty cycles. The results show that the proposed channel classification can identify 42 unused channels. If the power levels of wholebands (existing model) were analyzed instead of passband’s and guardband’s duty cycles, only 24 unoccupied channels were found. Furthermore, we propose the interference criteria, based on relative duty cycles across channels, to classify the abnormally used channels into interference sources and interference sinks, which have 16 and 15 channels, respectively. This information helps the dynamic spectrum sharing avoid or mitigate the interferences.

7 July 2023 in IEEE Access
Verified
Journal Article
Open access
ACAjalawit Chantaveerod
Ajalawit Chantaveerod
KWKampol Woradit
Kampol Woradit
ASAndrew Seagar
Andrew Seagar
Thunyawat LimpitiThunyawat Limpiti
Thunyawat Limpiti
Hydrologists usually gain insights into topographic variability by using a high-performance algorithm to estimate the catchment area from a digital elevation model (DEM) image. In the literature, the grid-based algorithms are more popular than the contour-based algorithms; however, the existing ones cannot reduce the error when higher resolution DEM is available. This paper introduces a new contour-based algorithm, formulated with the physically-based concept, to estimate catchment from contour-based DEM data. The formulation was derived from the semi-analytical solution of Laplace’s partial differential equation based on the boundary element method (BEM). With this approach, the algorithm can estimate the catchment area along the smooth surface water paths (SWPs), which are delineated from the physically-based algorithm in [1]. The proposed algorithm was validated with the standard synthetic surfaces, where the theoretical specific catchment areas (SCAs) for error assessment are exactly known. When estimating the SCAs with ordinary resolution, the average error of the estimated SCAs is between 14.19 and 2.32%, but the average error from the popular grid-based algorithms is between 77.8 and 17.0 %. With higher resolutions, between 12.5 and 0.88 meters, the proposed algorithm significantly reduces the average error from 15 to 0.8%.

3 June 2022 in IEEE Access
Verified
Journal Article
Open access
ACAjalawit Chantaveerod
Ajalawit Chantaveerod
KWKampol Woradit
Kampol Woradit
ASAndrew D. Seagar
Andrew D. Seagar
Thunyawat LimpitiThunyawat Limpiti
Thunyawat Limpiti
It is well-known that the delineated surface water paths (SWP) from a DEM image are essential in hydrology. Both grid-based and contour-based algorithms were proposed in the literature to improve the delineated SWP position’s accuracy. Compared to the grid-based algorithm, the contour-based algorithms usually give more accurate results but require higher computation resources, especially in case of the wide catchment. This paper introduces a new contour-based algorithm which is formulated with the semi-analytical solution of Laplace’s partial differential equation with boundary element method. This approach allows the algorithm to determine the SWP in any direction in order to keep the delineated SWP smooth. The proposed algorithm was validated with the standard synthetic surfaces, where theoretical SWPs are known for accuracy evaluation. The obtained SWPs are more accurate than that of the popular grid-based algorithms. Moreover, the proposed algorithm requires less computation resources when considering very long contour lines. In experimentation with a real DEM image, all delineated SWPs are absolute (no broken part) when the contour interval is equal to or less than 20 meters, and the spacing between adjacent discrete elevation data is 20 meters or narrower. This algorithm helps the hydrologists estimate the catchment area, which is useful for water management in flood and drought prevention.

16 September 2024 in IEEE Access
Verified
Journal Article
Open access
ACAjalawit Chantaveerod
Ajalawit Chantaveerod
KWKampol Woradit
Kampol Woradit
ASAndrew Seagar
Andrew Seagar
Thunyawat LimpitiThunyawat Limpiti
Thunyawat Limpiti
Hydrologists delineate surface water path (SWP) from digital elevation model (DEM) images to gain insights into catchment characteristics. Currently, high-resolution DEM can be obtained to improve the SWP delineation accuracy. It was found that accuracy is still the same for the popular existing grid-based algorithms, but is much higher for the physically-based and contour-based algorithms. Unfortunately, the contour-based algorithms suffer complexity at high resolution. Accordingly, we develop the algorithm to decrease the error with high-resolution DEMs by enhancing an existing contour-based algorithm, constructed with a physically-based concept, derived from the semi-analytical solution of Laplace’s partial differential equation through the boundary element method (BEM). To reduce the complexity, we propose the framework integrating the enhanced algorithm with pre-processing that reduces the input data size from very long contours by transforming those contours into the closed paths, exploited by the enhanced algorithm to delineate SWPs with numerical BEM-based solution. The results show the framework’s ability to successfully delineate the forward SWPs from hilltops to reservoirs over a real-world large-terrain DEM image and to depict the drainage networks flowing into real rivers. Analyzing the catchment boundary at the outlet along the real river, the framework successfully delineates the reverse SWPs from the outlet to hilltops and accurately demarcates the catchment boundary, consistent with the results from a popular GIS software. These findings indicate that the framework can reduce the complexity of the physically-based and contour-based algorithm in delineating the SWPs over a real-world large-terrain DEM image while maintaining robustness in problematic regions.

1 October 2026 in Emerging Science Journal
Verified
Journal Article
Open access
PDF file
UCUshaloy Chakma
Ushaloy Chakma
ACAjalawit Chantaveerod
Ajalawit Chantaveerod
KSKorakot Suwannarat
Korakot Suwannarat
Anindya NagAnindya Nag
Anindya Nag
Md Eshrat E AlahiMd Eshrat E Alahi
Md Eshrat E Alahi
The effectiveness of Landslide Early Warning Systems (LEWS) in resource-constrained tropical regions is often compromised by intermittent connectivity, stochastic environmental noise, and limited training data. To address these vulnerabilities, we aimed to design and field-validate a resilient, energy-autonomous IoT framework. Our methods involved engineering a low-cost (~$200 USD) custom sensor node capable of >14 days of energy autonomy, supported by a dual-mode LoRaWAN telemetry protocol. For data analysis, we developed a Random Forest classifier trained on 148,919 field data points, employing Recursive Exponential Moving Average feature engineering to minimize lag and an Effective Saturation (Se) normalization technique to evaluate heterogeneous soils. Key findings from field validation in Thailand demonstrated robust connectivity under severe Non-Line-of-Sight conditions (SNR down to -5.5 dB), with the baseline model achieving a Critical Event F1-Score of 0.97. As a major improvement and novelty, the integration of physics-informed constraints (Se) resolved performance variance across differing soil profiles, elevating the ultimate F1-score to 1.00. This physics-informed approach demonstrated unprecedented site-specific precision, improving critical recall by 14% and 5% in sandy clay and sandy clay loam environments, respectively, effectively eliminating false alarms while ensuring fail-safe detection.

3 December 2025 in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
Verified
Journal Article
Open access
ACAjalawit Chantaveerod
Ajalawit Chantaveerod
KWKampol Woradit
Kampol Woradit
ASAndrew Seagar
Andrew Seagar
Accurate catchment estimation is essential for water management, flood forecasting, and environmental planning. Traditional grid-based and contour-based methods are commonly used as baselines but often show limited accuracy, especially in large terrains with long or incomplete contours. This study presents an enhanced, physically based algorithm for catchment size estimation. The algorithm relies on elevation and gradient information obtained from a BEM-based numerical solution of Laplace’s equation, and is designed to work effectively with shortened, contour-based inputs. The algorithm is integrated into an adaptive framework that automates contour creation, applies robust preprocessing, and delineates surface water paths (SWPs) from real-world digital elevation models (DEMs). This integration enables accurate catchment size estimation while reducing computational complexity. Validation on both synthetic and real-world terrains confirms the framework’s effectiveness. On synthetic surfaces, the algorithm achieved estimation errors as low as 1% and improved with higher DEM resolution, unlike grid-based methods, which showed over 20% error with minimal improvement. Real-world tests showed that the framework handles noisy data, reduces processing time, and captures full upslope catchment areas—even in diverging SWP conditions. It also benefits from increased DEM resolution, where GIS-based methods often plateau. The outcome is a practical algorithm that improves catchment estimation accuracy with lower computational demands. It supports applications in water flow prediction, flood, and drought management, and landslide risk assessment. Future work will focus on scalability through graphics processing unit (GPU) and cloud computing, hydrological model validation, testing on complex terrains, and geographic information system (GIS) tool integration.