Silvia Ronda

Ms. Silvia Ronda

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in Ultrasonics
Verified
Journal Article
Closed access
FLFrancisco Javier Oyaga Landa
Francisco Javier Oyaga Landa
SRSilvia Ronda
Silvia Ronda
FEFrancisco Montero de Espinosa
Francisco Montero de Espinosa
DRDaniel Razansky
Daniel Razansky
XDXose Luis Dean-Ben
Xose Luis Dean-Ben

2 November 2017 in Advances in Applied Ceramics: Structural, Functional and Bioceramics
Verified
Journal Article
Closed access
SRSilvia Ronda
Silvia Ronda
FEFrancisco Montero de espinosa
Francisco Montero de espinosa
Many clinical surveys have evaluated the use of ultrasound in physiotherapy treatments, the question of its effectiveness still being under discussion possibly because of the randomized energy density applied, which depends on the acoustic pressure beam of the transducers. In this work, a phononic crystal made of holes in solid materials is the basis for the design of a transducer with a piston-like vibration pattern where the radial modes are stopped, thus favoring the thickness vibration and resulting in a better mechanical vibration amplitude and acoustic efficiency. Finite element simulations have been made of the standard transducer and the proposed design; then demonstrator devices have been manufactured and tested so experimental results could be compared to the calculated ones. The transducers with this phononic structure show an efficient piston-like emission. The electrical impedance, the emitting surface vibration pattern and the acoustic diffraction field have been calculated and experimentally measured.

31 March 2017 in Sensors
Verified
Journal Article
Open access
PDF file
SRSilvia Ronda
Silvia Ronda
JAJosé L Aragón
José L Aragón
EIElvira Iglesias
Elvira Iglesias
FEFrancisco Montero de espinosa
Francisco Montero de espinosa
It was recently proposed that the lateral resonances around the working resonance band of ultrasonic piezoelectric sandwich transducers can be stopped by a periodic array of circular holes drilled along the main propagation direction (a phononic crystal). In this work, the performance of different transducer designs made with this procedure is tested using laser vibrometry, electric impedance tests and finite element models (FEM). It is shown that in terms of mechanical vibration amplitude and acoustic efficiency, the best design for physiotherapy applications is when both, the piezoceramic and an aluminum capsule are phononic structures. The procedure described here can be applied to the design of power ultrasonic devices, physiotherapy transducers and other external medical power ultrasound applications where piston-like vibration in a narrow band is required.

25 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
SRSilvia Ronda
Silvia Ronda
MGMar Fernandez Gutierrez
Mar Fernandez Gutierrez
JRJulio San Roman
Julio San Roman
FEFrancisco Montero de espinosa
Francisco Montero de espinosa
Despite the use of therapeutic ultrasound in the treatment of soft tissue pathologies, there remains some controversy regarding its efficacy. In order to develop new treatment protocols, it is a common practice to carry out in vitro studies in cell cultures before conducting animal tests. The lack of reproducibility of the experimental results observed in the literature concerning in vitro experiments motivated us to establish a methodology for characterizing the acoustic field in culture plate wells. In this work, such acoustic fields are fully characterized in a real experimental configuration, with the transducer being placed in contact with the surface of a standard 12-well culture plate. To study the non-thermal effects of ultrasound on fibroblasts, two different treatment protocols are proposed: long pulse (200 cycles) signals, which give rise to a standing wave in the well with the presence of cavitation (ISPTP max = 19.25 W/cm2), and a short pulse (five cycles) of high acoustic pressure, which produces a number of echoes in the cavity (ISPTP = 33.1 W/cm2, with Pmax = 1.01 MPa). The influence of the acoustic intensity, the number of pulses, and the pulse repetition frequency was studied. We further analyzed the correlation of these acoustic parameters with cell viability, population, occupied surface, and cell morphology. Lytic effects when cavitation was present, as well as mechanotransduction reactions, were observed.

1 September 2016 in Ultrasonics
Verified
Journal Article
Closed access
JAJosé L Aragón
José L Aragón
RQR. Quintero-Torres
R. Quintero-Torres
JDJorge Luis Domínguez
Jorge Luis Domínguez
EIE. Iglesias
E. Iglesias
SRSilvia Ronda
Silvia Ronda
FEFrancisco Montero de espinosa
Francisco Montero de espinosa

19 February 2018
Verified
Conference Paper
Closed access
PDF file
FLFrancisco Javier Oyaga Landa
Francisco Javier Oyaga Landa
SRSilvia Ronda
Silvia Ronda
XDXosé Luís Deán-Ben
Xosé Luís Deán-Ben
DRDaniel Razansky
Daniel Razansky
FEFrancisco Montero de Espinosa
Francisco Montero de Espinosa
Medium intensity focused ultrasound (MIFU) holds promise in important clinical applications. Generally, the aim in MIFU is to stimulate physiological mechanisms that reinforce healing responses, avoiding reaching temperatures that can cause permanent tissue damage. The outcome of interventions is then strongly affected by the temperature distribution in the treated region, and accurate monitoring represents a significant clinical need. In this work, we showcase the capacities of 4D optoacoustic imaging to monitor tissue heating during MIFU. The proposed method allows localizing the ultrasound focus, estimating the peak temperature and measuring the size of the heat-affected volume. Calibration experiments in a tissue-mimicking phantom demonstrate that the optoacoustically-estimated temperature accurately matches thermocouple readings. The good performance of the suggested approach in real tissues is further showcased in experiments with bovine muscle samples.