Katharina Kuhn

Dr. Katharina Kuhn

orcid

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2015 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
KKKatharina Kuhn
Katharina Kuhn
SOSilke Ostertag
Silke Ostertag
MOMichael Ostertag
Michael Ostertag
MWMichael Walter
Michael Walter
Ralph Gunnar LuthardtRalph Gunnar Luthardt
Ralph Gunnar Luthardt
Heike RudolphHeike Rudolph
Heike Rudolph

4 June 2013 in Lasers in Surgery and Medicine
Verified
Journal Article
Closed access
PDF file
KKKatharina Kuhn
Katharina Kuhn
Heike RudolphHeike Rudolph
Heike Rudolph
RLRalph G. Luthardt
Ralph G. Luthardt
KSKarl Stock
Karl Stock
RDRolf Diebolder
Rolf Diebolder
RHRaimund Hibst
Raimund Hibst

20 February 2023 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
MDMarie-Theres Dawid
Marie-Theres Dawid
OMOvidiu Moldovan
Ovidiu Moldovan
Heike RudolphHeike Rudolph
Heike Rudolph
KKKatharina Kuhn
Katharina Kuhn
RLRalph G. Luthardt
Ralph G. Luthardt
The aim of this study was to conduct a systematic literature review with a subsequent meta-analysis on the technical complications and failures of removable partial denture (RPD) therapy in the moderately reduced dentition. A systematic literature search of established medical databases, last updated 06/2022, was conducted. RCTs and prospective and retrospective studies were included that had information on technical complications and failures of RPDs, at least 15 participants, an observation period of at least two years and a drop-out rate of less than 25%. Publications were selected on the title, abstract and full-text level by at least three of the participating authors. The evidence of the included studies was classified using the GRADE system. The bias risk was determined using the RoB2 tool and the ROBINS-I tool. Of 19,592 initial hits, 43 publications were included. Predominantly, retention of the prosthesis, retention loss of anchor crowns (decementations), fractures/repairs of frameworks, denture teeth, veneering or acrylic bases, and a need for relining were reported depending on prosthesis type and observation time. Focusing on technical complications and failures, only very heterogeneous data were found and publications with the highest quality level according to GRADE were scarce. Whenever possible, data on technical complications and failures should be reported separately when referencing the tooth, the prosthesis and the patient for comparability. Prostheses with differing anchorage types should be analyzed in different groups, as the respective complications and failures differ. A precise description of the kinds of complications and failures, as well as of the resulting follow-up treatment measures, should be given.

4 February 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
AKAnne Knipper
Anne Knipper
KKKatharina Kuhn
Katharina Kuhn
Ralph Gunnar LuthardtRalph Gunnar Luthardt
Ralph Gunnar Luthardt
Sigmar SchnutenhausSigmar Schnutenhaus
Sigmar Schnutenhaus
This randomized prospective clinical study aims to analyze the differences between the computer-assisted planned implant position and the clinically realized implant position using dynamic navigation. In the randomized prospective clinical study, 30 patients were recruited, of whom 27 could receive an implant (BLT, Straumann Institut AG, Basel, Switzerland) using a dynamic computer-assisted approach. Patients with at least six teeth in their jaws to be implanted were included in the study. Digital planning was performed using cone beam tomography imaging, and the visualization of the actual situation was carried out using an intraoral scan. Two different workflows with differently prepared reference markers were performed with 15 patients per group. The actual clinically achieved implant position was recorded with scan bodies fixed to the implants and an intraoral scan. The deviations between the planned and realized implant positions were recorded using evaluation software. The clinical examinations revealed no significant differences between procedures A and B in the mesiodistal, buccolingual and apicocoronal directions. For the mean angular deviation, group B showed a significantly more accurate value of 2.7° (95% CI 1.6–3.9°) than group A, with a value of 6.3° (95% CI 4.0–8.7°). The mean 3D deviation at the implant shoulder was 2.35 mm for workflow A (95% CI 1.92–2.78 mm) and 1.62 mm for workflow B (95% CI 1.2–2.05 mm). Workflow B also showed significantly higher accuracy in this respect. Similar values were determined at the implant apex. The clinical examination shows that sufficiently accurate implant placement is possible with the dynamic navigation system used here. The use of different workflows sometimes resulted in significantly different accuracy results. The data of the present study are comparable with the published findings of other static and dynamic navigation procedures.

15 January 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
KKKatharina Kuhn
Katharina Kuhn
DZDavid Zügel
David Zügel
VKVictor-Sebastian A. Korbay
Victor-Sebastian A. Korbay
TPThomas Papas
Thomas Papas
Sigmar SchnutenhausSigmar Schnutenhaus
Sigmar Schnutenhaus
Heike RudolphHeike Rudolph
Heike Rudolph
This randomized clinical study aimed at quantifying the gingival displacement performance in the vertical and horizontal directions of the 3M™ Astringent Retraction Paste (3M Oral Care, Seefeld, Germany) in comparison with the double-cord technique with aluminum chloride as an astringent. Afterward, any soft-tissue changes were assessed for 12 months. After inducing mild gingivitis, 18 probands received the intervention ‘cord’ and 22 probands received the intervention ‘paste’ at the palatal half of upper premolars prior to conventional impression making. The resulting plaster casts were digitized and analyzed for the vertical and horizontal gingival displacement, applying a newly developed computer-assisted methodology. The entire palatal half of the tooth was evaluated instead of only single sites. Under the condition of mild gingivitis, the gingival displacement performance was comparable for both techniques in the horizontal direction (width) and only somewhat better for the cord technique in the vertical direction (depth). The magnitude of displacement was in a similar range in both directions, with somewhat higher values in the vertical direction. The marginal gingiva height changes were of such low extent during the follow-up period of 12 months with only minimally higher values for the paste that they cannot be considered as clinically relevant recessions.

Verified
Journal Article
Open access
PDF file
KKKatharina Kuhn
Katharina Kuhn
Heike RudolphHeike Rudolph
Heike Rudolph
DZDavid Zügel
David Zügel
BJBenjamin A. Just
Benjamin A. Just
MHMichael Hrusa
Michael Hrusa
Ralph Gunnar LuthardtRalph Gunnar Luthardt
Ralph Gunnar Luthardt
This randomized clinical study examined the influence of the gingival condition—healthy versus mild inflammation—on sulcus representation and possible gingival recession for two gingival displacement procedures prior to conventional impression making. The interventions double cord technique or a kaolin paste containing aluminum chloride were applied to 40 probands. The opposite quadrant served as intrapersonal reference (split-mouth design). Precision impressions were then made. Extraoral digitization of the plaster models resulting from the reference impression prior to gingival displacement, the intervention impression and control impressions were the basis for the computer-aided three-dimensional analysis. After six months, a mild artificial gingivitis was induced, and the contralateral quadrant (cross-over design) was examined for the intervention. The gingivitis deteriorated the sulcus representation for the double cord technique group but did not affect the paste technique group. The gingival condition had no influence on the marginal gingiva height changes. The minor extent of those changes, which were measured up to six months after intervention at the palatal study site, were not considered to be in the clinically relevant range for gingival recession. For healthy gingiva, the cord technique showed superior sulcus representation compared to the paste technique. This advantage was lost to a great extent under the conditions of mild gingivitis.