The aim of this systematic review and meta-analysis is to analyze the accuracy of implant placement using computer-assisted dynamic navigation procedures. An electronic literature search was carried out, supplemented by a manual search. The literature search was completed in June 2020. The results of in vitro and clinical studies were recorded separately from each other. For inclusion in the review, the studies had to examine at least the prosthetically relevant parameters for angle deviation, as well as global deviation or lateral deviation at the platform of the implant. Sixteen of 320 articles were included in the investigation: nine in vitro and seven clinical studies. The meta-analysis showed values of 4.1° for the clinical studies (95% CI, 3.12–5.10) and 3.7° for the in vitro studies (95% CI, 2.31–5.10) in terms of the angle deviation. The global deviation at the implant apex of the implant was 1.00 mm for the clinical studies (95% CI, 0.83–1.16) and 0.91 mm for the in vitro studies (95% CI, 0.60–1.12). These values indicate no significant difference between the clinical and in vitro studies. The results of this systematic review show a clinical accuracy of dynamic computer-assisted navigation that is comparable to that of static navigation. However, the dynamic navigation systems show a great heterogeneity that must be taken into account. Moreover, currently there are few clinical data available. Therefore, further investigations into the practicability of dynamic navigation seem necessary.
(1) Background: The objective of implant prosthetic restoration is to ensure the best possible rehabilitation of function and esthetics. Optimal positioning of the implant with regard to the bone availability, surrounding soft tissue, and prosthetic sustainability should be strived for during implant placement. The factors influencing freehand implant placement and the accuracy achieved with this procedure are investigated in this prospective clinical study. (2) Methods: Implants were placed in the single-tooth edentulous sites of the premolar and molar areas in 52 patients. Three-dimensional (3D)-planning was performed virtually prior to the freehand implant operation, and the desired position of the implant was provided to the surgeon. (3) Results: The deviations between the planned and the actually achieved position with freehand implant placement showed the following mean values and standard deviations: angle 8.7 ± 4.8°, 3D deviation at the implant shoulder 1.62 ± 0.87 mm, mesiodistal deviation 0.87 ± 0.75 mm, buccolingual deviation 0.70 ± 0.66 mm, and apiocoronal deviation 0.95 ± 0.61 mm. The type of jaw had a significant influence on accuracy. Major deviations were observed in the lower jaw. Furthermore, the timing of implant placement influenced the mesiodistal deviation and angular deviation; (4) Conclusions: Freehand implant placement demonstrated a higher level of deviation between the planned and actually achieved implant positions. In particular, the ranges showed a large spread. From a prosthetic point of view, there may be complications during the restoration of the prosthetic crown if the implant exit point is not optimally located or if the implants show a high angular deviation.
30 November 2020 in Clinical Oral Implants Research
Objectives: This multicenter randomized controlled clinical trial was conducted to investigate whether the loading protocol of single dental implants placed in the midline of edentulous mandibles will influence the implant survival or prosthetic maintenance.Materials and Methods: In total, 158 patients were randomly assigned either to the immediate loading group (n = 81) or to the delayed loading group (n = 77). All implants were loaded with an overdenture retained by a ball attachment.Results: After 5 years, 102 patients attended the follow‐up investigation. Immediately loaded single implants in the midline of the edentulous mandible revealed a statistically significant lower survival rate than implants loaded conventionally over an observation period of 5 years. In the immediate loading group, 9 implants failed within the first three months of implant loading. No further implant loss was recorded for this group. Two implants failed in the delayed loading group, whereas one implant had to be removed during second‐stage surgery and the second five years after implant loading. Non‐inferiority of the survival rate of the midline implant of the immediate loading group, compared with the delayed loading group, could not be shown (p = .79, CI immediate loading: 74.9%; 100.0%, CI delayed loading: 73.0%; 100.0%). The observed difference in implant survival between the two treatment groups over time was statistically significant.Conclusions: The results of the present study indicate that immediate loading of a single mandibular implant in the edentulous mandible should be considered only in exceptional cases.
1 February 2015 in Computers in Biology and Medicine
Various treatment options for the prosthetic treatment of jaws where all molars are lost are under discussion. Besides the placement of implants, two main treatment types can be distinguished: replacement of the missing molars with removable dental prostheses and non-replacement of the molars, i.e. preservation of the shortened dental arch. Evidence is lacking regarding the long-term outcome and the clinical performance of these approaches. High treatment costs and the long time required for the treatment impede respective clinical trials.
1 January 2018 in Journal of Periodontal & Implant Science