Byeongjun Lee

Dr. Byeongjun Lee

Chungnam National University, Republic of Korea.
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2022 in Polymers
Verified
Journal Article
Open access
PDF file
CPChan Park
Chan Park
BLByeongjun Lee
Byeongjun Lee
JKJungmin Kim
Jungmin Kim
Haran LeeHaran Lee
Haran Lee
JKJeongbeom Kang
Jeongbeom Kang
Seong J. ChoSeong J. Cho
Seong J. Cho
Biology is characterized by smooth, elastic, and nonplanar surfaces; as a consequence, soft electronics that enable interfacing with nonplanar surfaces allow applications that could not be achieved with the rigid and integrated circuits that exist today. Here, we review the latest examples of technologies and methods that can replace elasticity through a structural approach; these approaches can modify mechanical properties, thereby improving performance, while maintaining the existing material integrity. Furthermore, an overview of the recent progress in wave/wrinkle, stretchable interconnect, origami/kirigami, crack, nano/micro, and textile structures is provided. Finally, potential applications and expected developments in soft electronics are discussed.

7 May 2021 in Polymers
Verified
Journal Article
Open access
PDF file
BLByeongjun Lee
Byeongjun Lee
YSYounghyeon Song
Younghyeon Song
CPChan Park
Chan Park
JKJungmin Kim
Jungmin Kim
JKJeongbeom Kang
Jeongbeom Kang
Seong J. ChoSeong J. Cho
Seong J. Cho
The patterning of electrospun fibers is a key technology applicable to various fields. This study reports a novel focused patterning method for electrospun nanofibers that uses a cylindrical dielectric guide. The finite elements method (FEM) was used to analyze the electric field focusing phenomenon and ground its explanation in established theory. The horizontal and vertical electric field strengths in the simulation are shown to be key factors in determining the spatial distribution of nanofibers. The experimental results demonstrate a relationship between the size of the cylindrical dielectric guide and that of the electrospun area accumulated in the collector. By concentrating the electric field, we were able to fabricate a pattern of less than 6 mm. The demonstration of continuous line and square patterning shows that the electrospun area can be well controlled. This novel patterning method can be used in a variety of applications, such as sensors, biomedical devices, batteries, and composites.

16 July 2024 in Nanoscale
Verified
Journal Article
Closed access
PDF file
CPChan Park
Chan Park
JKJungmin Kim
Jungmin Kim
JKJeongbeam Kang
Jeongbeam Kang
BLByeongjun Lee
Byeongjun Lee
Haran LeeHaran Lee
Haran Lee
Seong J. ChoSeong J. Cho
Seong J. Cho
A versatile coatable strain (CS) sensor was developed using a wet process, achieving a high sensitivity (GF ≈ 100). It overcame traditional polymer limitations, enabling real-time growth measurements on complex biological and non-planar surfaces.

20 March 2026 in Advanced Science
Verified
Journal Article
Open access
JKJungmin Kim
Jungmin Kim
KKKaram Kim
Karam Kim
BLByeongjun Lee
Byeongjun Lee
CPCheolJeong Park
CheolJeong Park
Seong J. ChoSeong J. Cho
Seong J. Cho
Woon-Hong YeoWoon-Hong Yeo
Woon-Hong Yeo
Wearable electroencephalography (EEG) devices offer a promising solution for continuous brain monitoring outside laboratory settings. However, maintaining stable signal quality over extended periods remains challenging, as skin‐mounted EEG systems are prone to contact‐induced noise caused by skin deformation and body motion. Here, we present a wrinkle‐adaptive kirigami structure and a soft, wearable EEG patch engineered to match subject‐specific forehead wrinkle patterns, thereby stabilizing the electrode‐skin interface. Our two‐step kirigami architecture integrates global conformability with localized strain accommodation, delivering anisotropic deformability and maintaining mechanical stability during facial motion. Leveraging an automated image‐based workflow, we enable scalable, individualized generation of kirigami patterns. When integrated into a soft, wireless wearable system, the personalized patch delivers consistently enhanced signal‐to‐noise ratios across multiple EEG frequency bands, even under diverse motion conditions in at‐home sleep settings. This technology demonstrates broad applicability for sleep EEG monitoring and underscores the potential of morphology‐aware structural design for next‐generation wearable EEG devices.

13 May 2026 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
BLByeongjun Lee
Byeongjun Lee
HYHoon Yi
Hoon Yi
JKJungmin Kim
Jungmin Kim
Jimin LeeJimin Lee
Jimin Lee
Seong J. ChoSeong J. Cho
Seong J. Cho
WYWoon-Hong Yeo
Woon-Hong Yeo
Sleep-related breathing disorders are prevalent yet frequently underdiagnosed, in part due to limitations of conventional respiratory monitoring technologies. Standard nasal cannulas introduce airflow resistance, discomfort, and poor long-term adherence, constraining at-home and longitudinal assessment. Here, we report a soft, skin-interfaced nasal patch that enables cannula-free, wireless monitoring of respiratory activity during sleep. The device is constructed from ultrathin, elastomeric materials that conform to the nasal surface, coupling respiratory-induced tissue deformation to a strain-sensing element. The mechanics of the skin–device interface and the elastomeric response govern the sensitivity and linearity of signal transduction, enabling quantitative capture of breathing dynamics. An integrated wireless platform transmits deformation signals directly to mobile devices, eliminating the need for external tubing or tethered modules. Modular fabrication permits replacement of the strain sensor and skin-contact interface without compromising mechanical performance. Mechanical characterization under physiologically relevant deformation demonstrates high repeatability and low hysteresis, while in vivo studies confirm that the patch accurately reproduces respiratory waveforms and correlates closely with gold-standard nasal cannula measurements. By integrating soft materials mechanics, wearable strain sensing, and wireless electronics, this system provides a minimally obtrusive platform for continuous respiratory monitoring. The class of technologies presented in this work establishes design principles for skin-interfaced devices, in which elastomeric mechanics, strain transduction, and wireless integration combine to enable quantitative, unobtrusive physiological monitoring in clinical and home environments.

30 April 2021 in Transactions of the Korean Society of Mechanical Engineers - A
Verified
Journal Article
Closed access
HKHyonguk Kim
Hyonguk Kim
SKSung Yeol Kwak
Sung Yeol Kwak
Seong J. ChoSeong J. Cho
Seong J. Cho
CPChan Park
Chan Park
JYJongwon Yoon
Jongwon Yoon
KKKwang Woo Kim
Kwang Woo Kim
현재 궤도 좌굴을 예방하기 위하여 고정형 레일 온도 모니터링 시스템을 통해 선로의 온도를 관리하고 있다. 하지만 설치된 레일에 비해 모니터링 시스템의 수가 부족하다. 또한 직접 계측에 사용되는 접촉식 온도계와 비접촉식 온도계는 측정 위치와 다양한 물리량에 따라 값이 달라진다. 본 연구에서는 기존의 레일 온도 계측 시스템의 한계를 개선한 휴대용 레일 온도 측정 시스템을 제안한다. 레일의 형상에 맞추어 설계하여 일정한 위치에서 높은 정확도로 온도를 측정할 수 있다. 또한 박막형 열전대의 사용과 기구부 설계를 통해 빠른 측정 속도와 낮은 측정 오차를 달성했다. 자석 기반의 부착 방식으로 시스템의 설치 및 제거가 용이하며, 스마트 기기에서 데이터의 모니터링 및 저장이 가능하다.