David Moreau

Dr. David Moreau


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 May 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AKAttila Kaszas
Attila Kaszas
GSGergely Szalay
Gergely Szalay
ASAndrea Slézia
Andrea Slézia
ABAlexandra Bojdán
Alexandra Bojdán
IVIvo Vanzetta
Ivo Vanzetta
DMDavid Moreau
David Moreau
Infrared neural stimulation is a promising tool for stimulating the brain because it can be used to excite with high spatial precision without the need of delivering or inserting any exogenous agent into the tissue. Very few studies have explored its use in the brain, as most investigations have focused on sensory or motor nerve stimulation. Using intravital calcium imaging with the genetically encoded calcium indicator GCaMP6f, here we show that the application of infrared neural stimulation induces intracellular calcium signals in Layer 2/3 neurons in mouse cortex in vivo. The number of neurons exhibiting infrared-induced calcium response as well as the amplitude of those signals are shown to be both increasing with the energy density applied. By studying as well the spatial extent of the stimulation, we show that reproducibility of the stimulation is achieved mainly in the central part of the infrared beam path. Stimulating in vivo at such a degree of precision and without any exogenous chromophores enables multiple applications, from mapping the brain’s connectome to applications in systems neuroscience and the development of new therapeutic tools for investigating the pathological brain.

9 August 2017 in Journal of Biophotonics
Verified
Journal Article
Closed access
PDF file
DMDavid Moreau
David Moreau
CLClaire Lefort
Claire Lefort
JPJolien Pas
Jolien Pas
SBSylvia M. Bardet
Sylvia M. Bardet
PLPhilippe Leveque
Philippe Leveque
RORodney Philip O’Connor
Rodney Philip O’Connor

27 September 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
NDNathan Dumas
Nathan Dumas
EPEmilie Pecchi
Emilie Pecchi
RORodney O’cOnnor
Rodney O’cOnnor
RBRémi Bos
Rémi Bos
DMDavid Moreau
David Moreau
Infrared neural stimulation (INS) emerges as a promising tool for stimulating the nervous system by its high spatial precision and absence of the use of exogenous agents into the tissue, which led to the first successful proof of concept in human brain. While neural networks have been the focal point of INS research, this technique is also non cell type specific as it triggers activity in non electrically excitable cells. Despite increasing interest, there remains to demonstrate well defined simultaneous astrocytic and neuronal signals in response to INS. Using calcium imaging, we show that INS has the capacity to initiate calcium signaling in both astrocytes and neurons simultaneously from the rostral lumbar spinal cord, each exhibiting distinct temporal and amplitude characteristics. Importantly, the mechanism underlying infrared-induced neuronal and astrocytic calcium signaling differ, with neuronal activity relying on sodium channels, whereas induced astrocytic signaling is predominantly influenced by extracellular calcium and TRPV4 channels. Furthermore, our findings demonstrate the frequency shift of neuronal calcium oscillations through infrared stimulation. By deepening our understanding in INS fundamentals, this technique holds great promise for advancing neuroscience, deepening our understanding of pathologies, and potentially paving the way for future clinical applications.

24 December 2024 in Sensors
Verified
Journal Article
Open access
PDF file
RMRita Matta
Rita Matta
ZBZsofia Balogh-Lantos
Zsofia Balogh-Lantos
ZFZoltán Fekete
Zoltán Fekete
MBMartin Baca
Martin Baca
Attila KaszasAttila Kaszas
Attila Kaszas
RORodney Philip O’Connor
Rodney Philip O’Connor
The primary method of treatment for patients suffering from drug-resistant focal-onset epilepsy is resective surgery, which adversely impacts neurocognitive function. Radio frequency (RF) ablation and laser ablation are the methods with the most promise, achieving seizure-free rates similar to resection but with less negative impact on neurocognitive function. However, there remains a number of concerns and open technical questions about these two methods of thermal ablation, with the primary ones: (1) heating; (2) hemorrhage and bleeding; and (3) poor directionality. Irreversible electroporation (IRE) is a proven method of focal ablation, which circumvents all three of the primary concerns regarding focal RF and laser ablation. Here, we demonstrate the in vivo application of a flexible implant with organic electrodes for focal ablation of epilepsy foci using high-frequency IRE (H-FIRE) in mice. Our results show that local, targeted ablation is possible in the close neighborhood of the electrode, paving the way for the clinical application in the treatment of focal epilepsy.

1 April 2025 in PLOS ONE
Verified
Journal Article
Open access
PDF file
RMRita Matta
Rita Matta
DRDavide Reato
Davide Reato
ALAlberto Lombardini
Alberto Lombardini
DMDavid Moreau
David Moreau
RORodney Philip O’Connor
Rodney Philip O’Connor
Electrical stimulation is a powerful tool for investigating and modulating brain activity, as well as for treating neurological disorders. However, understanding the precise effects of electrical stimulation on neural activity has been hindered by limitations in recording neuronal responses near the stimulating electrode, such as stimulation artifacts in electrophysiology or obstruction of the field of view in imaging. In this study, we introduce a novel stimulation device fabricated from conductive polymers that is transparent and therefore compatible with optical imaging techniques. The device is manufactured using a combination of microfabrication and inkjet printing techniques and is flexible, allowing better adherence to the brain’s natural curvature. We characterized the electrical and optical properties of the electrodes, focusing on the trade-off between the maximum current that can be delivered and optical transmittance. We found that a 1 mm diameter, 350 nm thick PEDOT:PSS electrode could be used to apply a maximum current of 130 μA while maintaining 84% transmittance (approximately 50% under 2-photon imaging conditions). We then evaluated the electrode performance in the brain of an anesthetized mouse by measuring the electric field with a nearby recording electrode and found values up to 30 V/m. Finally, we combined experimental data with a finite-element model of the in vivo experimental setup to estimate the distribution of the electric field underneath the electrode in the mouse brain. Our findings indicate that the device can generate an electric field as high as 300 V/m directly beneath the electrode, demonstrating its potential for studying and manipulating neural activity using a range of electrical stimulation techniques relevant to human applications. Overall, this work presents a promising approach for developing versatile new tools to apply and study electrical brain stimulation.

19 August 2021 in Sensors
Verified
Journal Article
Open access
PDF file
YAyvan avdeew
yvan avdeew
VBVictor Bergé-laval
Victor Bergé-laval
VLVirginie Lerolle
Virginie Lerolle
GDGabriel Dieuset
Gabriel Dieuset
DMDavid Moreau
David Moreau
AHAlfredo Hernández
Alfredo Hernández
Effective closed-loop neuromodulation relies on the acquisition of appropriate physiological control variables and the delivery of an appropriate stimulation signal. In particular, electroneurogram (ENG) data acquired from a set of electrodes applied at the surface of the nerve may be used as a potential control variable in this field. Improved electrode technologies and data processing methods are clearly needed in this context. In this work, we evaluated a new electrode technology based on multichannel organic electrodes (OE) and applied a signal processing chain in order to detect respiratory-related bursts from the phrenic nerve. Phrenic ENG (pENG) were acquired from nine Long Evans rats in situ preparations. For each preparation, a 16-channel OE was applied around the phrenic nerve’s surface and a suction electrode was applied to the cut end of the same nerve. The former electrode provided input multivariate pENG signals while the latter electrode provided the gold standard for data analysis. Correlations between OE signals and that from the gold standard were estimated. Signal to noise ratio (SNR) and ROC curves were built to quantify phrenic bursts detection performance. Correlation score showed the ability of the OE to record high-quality pENG. Our methods allowed good phrenic bursts detection. However, we failed to demonstrate a spatial selectivity from the multiple pENG recorded with our OE matrix. Altogether, our results suggest that highly flexible and biocompatible multi-channel electrode may represent an interesting alternative to metallic cuff electrodes to perform nerve bursts detection and/or closed-loop neuromodulation.