This work presents the overall model of the doubly fed induction generator (DFIG) and proposes a new control design for the grid side converter of the concerned DFIG plant. The system under study consists of two DFIG wind turbines which are connected to the grid by a bi-directional Z-source inverter. In order to ameliorate the DC link voltage regulation of the DFIG generation plant; particularly, a new supervised control method is introduced and is directly applied to the grid side converter (GSC). In this way, initially, by tuning two control coefficients (CCs) which forms the footprint of uncertainty (FOU), a double-input interval type-2 fuzzy logic (DIT2-FL) is designed for the GSC system. The best setting of the control coefficients for the desired performance of the concerned system is recommended and a new DIT2-FL supervised online adaptive neuro fuzzy inference system (ANFIS) is then developed accordingly. By implementing the supervised controller, the dynamic behavior of the tested wind turbines under two distinct operations for low/high wind speeds is investigated. Detailed experimental outcomes have been presented to ascertain the correctness and accuracy of the suggested control methodology. Compared with the prevalent state-of-the-art techniques, the suggested controller leads to remarkable transient improvement of closed-loop DFIG system.
Extensive use of wind turbine (WT) systems brings remarkable challenges to the stability and safety of the power systems. Due to the difficulty and complexity of modeling such large plants, the model-independent strategies are preferred for the control of the WT plants which eliminates the need to model identification. This current work proposes a novel model-independent control methodology in the rotor side converter (RSC) part to ameliorate low voltage ride through (LVRT) ability especially for the doubly-fed induction generator (DFIG) WT. A novel model-independent nonsingular terminal sliding mode control (MINTSMC) was developed based on the principle of the ultra-local pattern. In the suggested controller, the MINTSMC scheme was designed to stabilize the RSC of the DFIG, and a sliding-mode supervisor was adopted to determine the unknown dynamics of the proposed system. An auxiliary dual input interval type 2 fuzzy logic control (DIT2-FLC) was established in a model-independent control structure to remove the estimation error of the sliding mode observer. Real-time examinations have been carried out using a Real-Time Model in Loop (RT-MiL) for validating the applicability of the proposed model-independent control in a real-time platform. To evaluate the usefulness and supremacy of the MINTSMC based DIT2-FLC, the real-time outcomes are compared with outcomes of RSC regulated conventional PI controller and MINTSMC controller.
This paper proposes a novel high-gain AC-DC converter based on the Cockcroft-Walton (CW) voltage multiplier which can be utilized in motor drive systems with low input voltage. In this topology, use of the voltage multiplier and boost circuit results in the increment of converter gain which has a significant impact on the cost and efficiency of the system. Moreover, in this converter, the AC voltage is directly changed to DC voltage using the switching method in high frequency and, as well, the power factor is corrected. Besides, this high-frequency converter contributes to the reduction of output ripple. On the other hand, cost efficiency, the low voltage stress on capacitors and diodes, compactness, and the high voltage ratio, are achieved from the Cockcroft-Walton circuit. Furthermore, the hysteresis method is presented for converter switching to correct the power factor. The converter is simulated in MATLAB software to demonstrate the effectiveness of the suggested method. Lastly, a laboratory prototype of the suggested converter is built, several tests are done in order to verify the theoretical analysis, and comprehensive comparison with the state-of-the-art converter is done.