Nguyen Minh Phu

Prof. Dr. Nguyen Minh Phu

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PTPham Ba Thao
Pham Ba Thao
DTDuong Cong Truyen
Duong Cong Truyen
NPNguyen Minh Phu
Nguyen Minh Phu
In this paper, a solar air collector duct equipped with baffles on a back plate was numerically investigated. The Reynolds number (Re) was varied from 5000 to 20,000, the angle baffle (a) from 30° to 120°, the baffle spacing ratio (Pr) from 2 to 8, and the baffle blockage ratio (Br) from 0.375 to 0.75 to examine their effects on the Nusselt number (Nu), the friction factor (f), and the thermohydraulic performance parameter (η). The 2D numerical simulation used the standard k-ε turbulence model with enhanced wall treatment. The Taguchi method was used to design the experiment, generating an orthogonal array consisting of four factors each at four levels. The optimization results from the Taguchi method and CFD analysis showed that the optimal geometry of a = 90°, Pr = 6, and Br = 0.375 achieved the maximum η. The influence of Br on all investigated parameters was considerable because as Br increased, a larger primary vortex region was formed downstream of the baffle. At Re = 5000 and the optimal geometry parameters, a maximum η of 1.01 was reached. A baffle angle between 60° and 90° achieved a high Nusselt number due to the impingement heat transfer.

27 March 2021 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
NLNguyen Thanh Luan
Nguyen Thanh Luan
NPNguyen Minh Phu
Nguyen Minh Phu
In this paper, different flow configurations of multipass flat-plate air collectors are explored. Multiple passes are formed from glass cover, absorber plate, and back plate. Five types of air collectors were analysed and optimized with respect to maximum efficiencies and minimum cost. The analytical prediction of the heat exchanger, pressure loss, and efficiencies was presented. The effects of mass flow rate from 0.01 to 0.02 kg/s, air channel depth from 15 to 30 mm, and collector length from 1.5 to 2.5 m on different configurations were examined and compared. The results of the parametric study show that the triple-pass type has the greatest efficiency, whereas the smallest efficiency is of the single-pass type. Among double-pass types, the type with two glass covers and natural convection heat transfer achieved the highest effective and exergy efficiencies due to a reduction in the top loss. Double-pass type with single glass cover is not recommended from both energy and exergy standpoints. As the collector length increases, the effective efficiency decreases, but the exergy efficiency increases. The exergy performance of the triple-pass type can reach up to 5% at the air flow rate of 0.005 kg/s. Finally, multiobjective optimization using the preference selection index method is conducted with three targets including effective efficiency, exergy efficiency, and number of plates. Optimal results show that the triple-pass type with the lowest air flow rate and the longest length is the best. The effective and exergy efficiencies for the best case were found to be about 52.1% and 4.7%, respectively. However, this type with the highest flow rate and the shortest length is the worst.

7 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
NPNguyen Minh Phu
Nguyen Minh Phu
TNTu Thien Ngo
Tu Thien Ngo
HNHap Nguyen
Hap Nguyen
In this paper, a triple-pass solar air heater with three inlets is analytically investigated. The effects of airflow ratios of the second and third passes (ranging from 0 to 0.4), and the Reynolds number of the third pass (ranging from 8000 to 18,000) on the thermohydraulic efficiency and entropy generation are assessed. An absorber plate equipped with rectangular fins on both sides is used to enhance heat transfer. The air temperature change in the passes is represented by ordinary differential equations and solved by numerical integration. The results demonstrate that the effect of the third pass airflow ratio on the thermohydraulic efficiency and entropy generation is more significant than that of the second pass airflow ratio. The difference in air temperature through the collector shows an insignificant reduction, but the air pressure loss is only 50% compared with that of a traditional triple-pass solar air heater. Increasing the air flow ratios dramatically reduces entropy generation. Multi-objective optimization found a Reynolds number of 11,156 for both the airflow ratio of the second pass of 0.258 and airflow ratio of the third pass of 0.036 to be the an optimal value to achieve maximum thermohydraulic efficiency and minimum entropy generation.

21 April 2023 in Environmental Science and Pollution Research
Verified
Journal Article
Closed access
PDF file
NHNguyen Van Hap
Nguyen Van Hap
PNPhan Thanh Nhan
Phan Thanh Nhan
HHHuynh Phuoc Hien
Huynh Phuoc Hien
NPNguyen Minh Phu
Nguyen Minh Phu

1 June 2023 in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
Verified
Journal Article
Open access
PDF file
DHDoan Thi Hong Hai
Doan Thi Hong Hai
NPNguyen Minh Phu
Nguyen Minh Phu
In this paper, three mathematical models to predict the air collector temperature are reviewed and analyzed. These three models were drawn from 30 publications between 1980 and 2022. The models include lumped model (model 1), a one-dimensional (1D) steady model (model 2), and 1D unsteady model (model 3). The models are established based on the energy balance of the heat exchanger surfaces and the airflow. Solution techniques for models are presented using a system of linear equations, numerical integral, and finite difference method. The results of the sensitivity analysis of the models indicate that the temperatures of the air exiting the collector are similar. Model 3 considers the thickness of the glass cover, absorber plate, and bottom plate thus having the effect of thermal inertia in the morning and afternoon. The maximum difference of outlet air temperature between models 1 and 2 is 0.18 K. The highest outlet air temperature deviation of 0.77 K between models 1 and 3 occurred at 8 AM. When the thicknesses are negligible, the temperature distribution along the air collector of models 2 and 3 is the same. In other words, model 3 should be used when there is the presence of the thickness of the plates and the glass cover.

15 August 2025 in Scientific Reports
Verified
Journal Article
Open access
NHNguyen Van Hap
Nguyen Van Hap
PNPhan Thanh Nhan
Phan Thanh Nhan
NPNguyen Minh Phu
Nguyen Minh Phu
In current numerical work, a mathematical model for an air collector with latent heat storage is established and solved using the finite difference method. The glass, absorber plate, and air flow temperatures are described in one-dimensional unsteady terms. The storage material simulation is formed by a two-dimensional unsteady modeling and solved using the enthalpy method. By analyzing the temperature distribution and phase change behavior within the PCM using a two-dimensional unsteady model, this research provides a more detailed understanding of the thermal storage process compared to studies employing one-dimensional models. The mathematical model was validated by an outdoor experiment under prevailing climatic conditions in Ho Chi Minh City, Vietnam. The absorber plate is equipped with longitudinal rectangular fins to enhance heat transfer. Height of storage material, air flow rate and fin geometries are set as independent parameters to investigate phase change in latent storage and daily performance. Simulation results show that a storage height of 20 cm is suitable to fully liquify and to extend the operating time to 21:00. Attaching the fins increases the daily efficiency up to 13.7% compared to that of a smooth duct air collector. Latent heat storage provides the most uniform outlet air temperature compared to sensible storage and without storage. The standard deviation of outlet air temperature with time of day is 6.34 °C, 8.47 °C, and 9.20 °C for the types of latent heat storage, sensible heat storage, and without storage, respectively.