In this paper, a triple-pass solar air heater with three inlets is analytically investigated. The effects of airflow ratios of the second and third passes (ranging from 0 to 0.4), and the Reynolds number of the third pass (ranging from 8000 to 18,000) on the thermohydraulic efficiency and entropy generation are assessed. An absorber plate equipped with rectangular fins on both sides is used to enhance heat transfer. The air temperature change in the passes is represented by ordinary differential equations and solved by numerical integration. The results demonstrate that the effect of the third pass airflow ratio on the thermohydraulic efficiency and entropy generation is more significant than that of the second pass airflow ratio. The difference in air temperature through the collector shows an insignificant reduction, but the air pressure loss is only 50% compared with that of a traditional triple-pass solar air heater. Increasing the air flow ratios dramatically reduces entropy generation. Multi-objective optimization found a Reynolds number of 11,156 for both the airflow ratio of the second pass of 0.258 and airflow ratio of the third pass of 0.036 to be the an optimal value to achieve maximum thermohydraulic efficiency and minimum entropy generation.
The objective of this study is to improve the exit flow uniformity of a gas torch with multiple exit holes for effective heating of a steel plate. The torch was simulated, and combustion experiments were performed for validation. Based on a basic model, three different revised models were designed and analyzed with the software ANSYS FLUENT 18.2. The flow uniformity (γ) of the velocity distribution at the multiple exit holes was investigated with the pressure drop ranging from 100 to 500 Pa. The basic model had flow uniformity ranging from 0.849 to 0.852, but the three new models had γ1 = 0.901–0.912, γ2 = 0.902–0.911, and γ3 = 0.901–0.914, respectively. The maximum percentage difference of the flow uniformity index between the three new models and the basic model was 7.3%. The basic model with nonuniform flow distribution made a temperature difference of the back side of the steel plate from the center to the edge of around 229 °C, while the modified model with uniform flow distribution had a smaller temperature difference of 90 °C. The simulation results showed good agreement with our experimental results for both the basic model and the modified model. The modified gas torch made a wider and more uniform temperature distribution on a preheated steel plate than the basic one. The results revealed that a trade-off between cost and flow uniformity, as well as the new gas torch, could be applied to a steel-plate preheating process before welding.
The temperature distribution on a steel plate during a preheating process was compared using gas torch models with and without guide vanes. Numerical simulations were done using ANSYS FLUENT software, and experiments were done using thermal images obtained by a TVS-200EX infrared thermal camera. Liquefied petroleum gas (LPG) was used as fuel for the gas torch in the simulation and experiment. The temperature distribution on the steel plate and the flame region were first compared. The temperature increase caused by the flame concentration with the guide vanes was 65 °C. The transient and steady-state temperature distribution on the back side of the steel plate were then examined. The results showed good agreement between the simulation and experimental results. At steady state, the back-side temperature deviation of the steel plate between the numerical simulation and experimental results was approximately 4.9%. The effects of the equivalence ratio (Φ), Reynolds number (Re), and the downstream distance ratio of the combustion gas from the torch outlet to the steel plate (H/d) on the temperature distribution were also investigated. The highest temperature distribution was found in stoichiometric combustion. The temperature of the plate increased as the Reynolds number increased from 2368 to 4876 but decreased as the distance ratio (H/d) increased from 25 to 75. The guide vane angles at the gas torch outlet were from 30 to 60 degrees, and the angle of 40 degrees resulted in the highest temperature of the steel plate.
In this chapter, a water-filled square cavity with left hot wall and right cold wall was numerically investigated. The hot and cold wall temperatures are 10°C and 0°C respectively to examine the density inversion of natural convection water, i.e. water at 4°C. In the middle of the square, there are circular and elliptical bodies to study fluid–structure interaction in terms of the thermohydraulic behavior and entropy generation. 2D numerical simulation was performed using finite volume method in Ansys fluent software with the assumption of laminar flow. The simulation results are compared with benchmark data to determine reliability. The results indicate that the body insertions increase the convection heat transfer coefficients at the best heat transfer positions due to impingement heat transfer. An increase in heat transfer rate of 1.06 times is observed in the case of circular body compared to none. There are three primary eddies in the cavity with bodies, whereas the cavity without body has two primary eddies. Maximum entropy generation was found in the upper right corner of cavity mainly due to high horizontal temperature gradient. Bodies of circle and vertical ellipse have almost the same thermohydraulic and entropy generation characteristics due to the same horizontal dimension which mainly effects on the downward natural convection current. The entropy generation of cavity with circular body is 1.23 times higher than that of the cavity without body. At positions y/L = 1 on the hot wall and y/L = 0.74 on the cold wall, the convection heat transfer coefficient is close to zero due to stagnant fluid.
30 August 2024 in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
Co-generation of heat and electricity from solar cells is an energy efficient option because the photovoltaic (PV) efficiency is less than twenty percent, the rest goes to heat. In this paper, the heat emitted from the PV panel is used to produce hot air which is useful heat and to reduce the PV cell temperature thereby increasing the system performance. Independent parameters include air mass flow rate (), air channel height (H), PV panel aspect ratio (Ra), and environmental parameters (temperature, wind velocity, solar intensity) to investigate their influence on power and heat generation, and performances. The mathematical description of the system is formed using a lumped parameter model. The analytical results show that the overall performance is maximized at certain design parameters. This phenomenon is due to the trade-off between power generation, heat output, and fan power with a design specification. Optimizing the overall efficiency using a genetic algorithm (GA), which is a metaheuristic based on the principles of natural selection and categorized as part of the broader group of evolutionary algorithms, yields the maximum value of 98.76% at the optimal parameters = 0.3032 kg/s, H = 27.37 mm, and Ra = 1.809.
28 October 2022 in Journal of Technical Education Science
Điều hòa không khí trung tâm loại VRF ngày càng được sử dụng rộng rãi trong các tòa nhà thương mại bởi vì ưu điểm nổi bật của nó, đặc biệt trong các tòa nhà có tải lạnh biến đổi rất lớn. Khi số lượng dàn nóng được lắp đặt theo cụm tăng lên dẫn đến hệ số làm lạnh của hệ thống giảm do ảnh hưởng của dòng không khí nóng bị hút trở lại dàn nóng. Trong nghiên cứu này, mô hình 3D của cụm dàn nóng máy lạnh VRF lắp đặt trên sân thượng được xây dựng và nghiên cứu thông qua phương pháp mô phỏng CFD bằng phần mềm Ansys Fluent. Các kết quả mô phỏng chỉ ra rằng nhiệt độ không khí vào các dàn ngưng ở vùng trung tâm tăng cao so với vùng bên ngoài. Khi lắp ống hướng dòng cho các dàn nóng làm nhiệt độ trung bình không khí vào dàn nóng giảm 2,3%, trong khi đó nhiệt độ lớn nhất giảm đi 4%. Kết quả nghiên cứu này có thể dùng để tham khảo cho việc tối ưu thiết kế lắp đặt cụm dàn nóng máy lạnh loại VRF.