Pre-processing is a crucial step in analyzing spectra from Fourier transform infrared (FTIR) spectroscopy because it can reduce unwanted noise and enhance system performance. Here, we present the results of pre-processing technique optimization to facilitate the detection of pepper yellow leaf curl virus (PYLCV)-infected chilli plants using FTIR spectroscopy. Optimization of a range of pre-processing techniques was undertaken, namely baseline correction, normalization (standard normal variate, vector, and min-max), and de-noising (Savitzky-Golay (SG) smoothing, 1st and 2 derivatives). The pre-processing was applied to the mid-infrared spectral range (4000 - 400 cm-1) and the biofingerprint region (1800 - 900 cm-1) then the discrete wavelet transform (DWT) was used for dimension reduction. The pre-processed data were then used as an input for classification using a multilayer perceptron neural network, a support vector machine, and linear discriminant analysis. The pre-processing method with the highest classification model accuracy was selected for the further use in the processing. It was seen that only the SG 1st derivative method applied to both wavenumber ranges could produce 100% accuracy. This result was supported by principal component analysis clustering. Thus, we have demonstrated that by using the right pre-processing technique, classification success can be increased, and the process simplified by optimization and minimization of the technique used.
Pepper yellow leaf curl virus (PYLCV) is a threat to chili plants and can significantly reduce yields. This study aimed as a pilot project to detect PYLCV by analyzing compounds emitted by chili plants using gas chromatography-mass spectrometry (GC-MS). The samples investigated in this research were PYLCV-infected and PYLCV-undetected chili plants taken from commercial chili fields. The infection status was validated by using a polymerase chain reaction (PCR) test. A headspace technique was used to extract the volatile organic compounds emitted by plants. The analysis of GC-MS results began with pre-processing, analyzing sample compound variability with a boxplot analysis, and sample classification by using a multivariate technique. Unsupervised multivariate technique principal component analysis (PCA) was performed to discover whether GC-MS could identify PYLCV-infected or not. The results showed that PYLCV-infected and PYLCV-undetected chili plants could be differentiated, with a total percent variance of the first three principal components reaching 91.32%, and successfully discriminated between PYLCV-infected and PYLCV-undetected chili plants. However, more comprehensive studies are needed to find the potential biomarkers of the infected plants.
2 August 2025 in Computers and Electronics in Agriculture
An electronic nose (e-nose) consisting of a commercially metal oxide based gas sensor array has been used for measuring rapidly the odor of three kinds of herbal drink (hereafter as jamu). This research was focused on how to apply the existing preprocessing techniques on the analysis the e-nose output. In this case, two pre-processing techniques were used, i.e. the discrete wavelet transform (DWT) and a statistical technique of principal component analysis (PCA). The DWT of daubechies3 level one was used as the preprocessing technique. The first investigation was focused on differentiation of three kinds of jamu, and the second one was focused on the detection of the spoilage degree of jamu during 5 days consecutively. The total plate count (TPC) was also measured to confirm the PCA score plot of spoilage levels by describing more than 95% of the total variance in the data. It counts the number of the bacterial colonies on the jamu. As results, the e-nose is able to differentiate three kinds of fresh jamu. The spillage levels shown by the e-nose is in accordance with the TPC measurement. Therefore, the e-nose may show a promising rapid instrument for quality assessment of jamu and other herbals.
A conventional stethoscope (an acoustic stethoscope) is an acoustic medical device that is always used for preliminary examination of patients with any heart abnormalities. The main disadvantage of acoustic stethoscope is its dependence on how to use it and the experience of the examining physician. This paper presents a simple electronic stethoscope design in Phonocardiograph system that is free from subjectivity of doctors or other medical personnel. This electronic stethoscope is made sensitive in order to capture as many acoustic signal as possible from the activities of the human body, especially the heart and lungs. The design of this electronic stethoscope consists of chest piece, a pipe with proper acoustic impedance, mic condenser, mic preamp, and battery. The output of the mic preamp is connected to the mic channel on the laptop. The recording signal then processed separately. The repeatability of output signal was investigated in this paper. The signal was analyzed by using the Fast Fourier Transform (FFT). The result showed that the frequency responsea of the output signals are consistent, hence the instrument is reliable. Furthermore, the frequency response of the system with filter that connecting chest piece and mic condensor were also investigated.
1 November 2019 in Journal of Physics: Conference Series
Natural Animal Sound Spectrum Characterization based on Fourier analysis is a undamental scientific study of the spectrum of natural animal sounds that can be used as a stimulator of growth and productivity in food intensification. The results of characterization are very useful for adding scientific treasures in the field of biophysics, especially to support the use of natural animal sounds as stimulators of growth and productivity of food crops through spectrum analysis based on Fourier analysis so that it has a strong theoretical basis to be developed into an applied industry in the field of food intensification. Natural animal sound spectrum is obtained by recording animal sounds naturally in nature by using a voice recorder. Furthermore, the sound of these natural animals analyzed their spectrum characteristics using Adobe Audition to determine the peak frequency produced. Sound spectrum characterization which has peak frequency sonic bloom between 3000Hz - 5000 Hz is made as an audio stimulator for growth and productivity of food crops. From various 27 sources of animal sounds recorded and analyzed, there are 17 types of animals that have frequency peaks in range sonic blooms (3000-5000 Hz) and can be produced into stimulators and 1 combined stimulator. While the results of the sound timbre analysis of each animal has a frequency range including: 1-1000 Hz a number of 6 animals, 1000-2000 Hz of 8 animals, 2000-3000 Hz a number of 14 animals, 3000-4000 Hz a number of 12 animals, 4000-5000 Hz is 2 animals, and 5000-6000 Hz is 4 animals.