Rayleigh‐Bénard convective PCR is a simple and effective design for amplification of DNA. Convective PCR is, however, extremely sensitive to environmental temperature fluctuations, especially when using small‐ diameter test tubes. Therefore, this method is inherently unstable with limited applications. Here, we present a convective PCR device that has been modified by adding thermal baffles. With this thermally baffled device the influence from fluctuations in environmental temperature were significantly reduced, even in a wind tunnel (1 m/s). The thermally baffled PCR instrument described here has the potential to be used as a low‐cost, point‐of‐care device for PCR‐based molecular diagnostics in the field.
In this study, the sensing properties of an amorphous indium gallium zinc oxide (a-IGZO) thin film at ozone concentrations from 500 to 5 ppm were investigated. The a-IGZO thin film showed very good reproducibility and stability over three test cycles. The ozone concentration of 60–70 ppb also showed a good response. The resistance change (ΔR) and sensitivity (S) were linearly dependent on the ozone concentration. The response time (T90-res), recovery time (T90-rec), and time constant (τ) showed first-order exponential decay with increasing ozone concentration. The resistance–time curve shows that the maximum resistance change rate (dRg/dt) is proportional to the ozone concentration during the adsorption. The results also show that it is better to sense rapidly and stably at a low ozone concentration using a high light intensity. The ozone concentration can be derived from the resistance change, sensitivity, response time, time constant (τ), and first derivative function of resistance. However, the time of the first derivative function of resistance is shorter than other parameters. The results show that a-IGZO thin films and the first-order differentiation method are promising candidates for use as ozone sensors for practical applications.
The modalities for performing stereotactic radiotherapy (SRT) on the brain include the cone-based linear accelerator (linac), the flattening filter-free (FFF) volumetric modulated arc therapy (VMAT) linac, and tomotherapy. In this study, the cone-based linac, FFF-VMAT linac, and tomotherapy modalities were evaluated by measuring the differences in doses delivered during brain SRT and experimentally assessing the accuracy of the output radiation doses through clinical measurements. We employed a homemade acrylic dosimetry phantom representing the head, within which a thermoluminescent dosimeter (TLD) and radiochromic EBT3 film were installed. Using the conformity/gradient index (CGI) and Paddick methods, the quality of the doses delivered by the various SRT modalities was evaluated. The quality indicators included the uniformity, conformity, and gradient indices. TLDs and EBT3 films were used to experimentally assess the accuracy of the SRT dose output. The dose homogeneity indices of all the treatment modalities were lower than 1.25. The cone-based linac had the best conformity for all tumors, regardless of the tumor location and size, followed by the FFF-VMAT linac; tomography was the worst-performing treatment modality in this regard. The cone-based linac had the best gradient, regardless of the tumor location and size, whereas the FFF-VMAT linac had a better gradient than tomotherapy for a large tumor diameter (28 mm). The TLD and EBT3 measurements of the dose at the center of tumors indicated that the average difference between the measurements and the calculated dose was generally less than 4%. When the 3% 3-mm gamma passing rate metric was used, the average passing rates of all three treatment modalities exceeded 98%. Regarding the dose, the cone-based linac had the best conformity and steepest dose gradient for tumors of different sizes and distances from the brainstem. The results of this study suggest that SRT should be performed using the cone-based linac on tumors that require treatment plans with a steep dose gradient, even as the tumor is slightly irregular, we should also consider using a high dose gradient of the cone base to treat and protect the normal tissue. If normal tissues require special protection exist at positions that are superior or inferior to the tumor, we can consider using tomotherapy or Cone base with couch at 0° for treatment.
Through two-photon lithographic processes, we report experimentally and numerically a series of photoinduced tunable polymerization patterns in shapes from straight channel, serpentine curve, to periodic grating when an ultrashort femtosecond laser pulse directly writes in a liquid-crystal-monomer mixture along a line for different scanning speeds. Laser beams with polarization perpendicular to the direction of writing and the alignment of liquid crystals, produce snake-shaped patterns at an intermediate scan rate.
The fertilized egg is an indispensable production platform for making egg-based vaccines. This study was divided into two parts. In the first part, image processing was employed to analyze the absorption spectrum of fertilized eggs; the results show that the 580-nm band had the most significant change. In the second part, a 590-nm-wavelength LED was selected as the light source for the developed detection device. Using this device, sample images (in RGB color space) of the eggs were obtained every day during the experiment. After calculating the grayscale value of the red layer, the receiver operating characteristic curve was used to analyze the daily data to obtain the area under the curve. Subsequently, the best daily grayscale value for classifying unfertilized eggs and dead-in-shell eggs was obtained. Finally, an industrial prototype of the device designed and fabricated in this study was operated and verified. The results show that the accuracy for detecting unfertilized eggs was up to 98% on the seventh day, with the sensitivity and Youden’s index being 82% and 0.813, respectively. On the ninth day, both accuracy and sensitivity reached 100%, and Youden’s index reached a value of 1, showing good classification ability. Considering the industrial operating conditions, this method was demonstrated to be commercially applicable because, when used to detect unfertilized eggs and dead-in-shell eggs on the ninth day, it could achieve accuracy and sensitivity of 100% at the speed of five eggs per second.