J.  Israel Martinez Lopez

Dr. J. Israel Martinez Lopez

Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Ave. Eugenio Garza Sada 2501, Monterrey, N.L., México, 64849
+1
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 February 2009 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
J.  Israel Martinez LopezJ. Israel Martinez Lopez
J. Israel Martinez Lopez
HMHéctor Moncada-Hernández
Héctor Moncada-Hernández
JBJavier L. Baylon-Cardiel
Javier L. Baylon-Cardiel
SMSergio O. Martínez-Chapa
Sergio O. Martínez-Chapa
Marco Rito-PalomaresMarco Rito-Palomares
Marco Rito-Palomares
BLBlanca Lapizco-Encinas
Blanca Lapizco-Encinas

16 May 2016 in Sensors
Verified
Journal Article
Open access
PDF file
J.  Israel Martinez LopezJ. Israel Martinez Lopez
J. Israel Martinez Lopez
MMMauricio Mojica
Mauricio Mojica
CRCiro Rodriguez
Ciro Rodriguez
Hector SillerHector Siller
Hector Siller
Despite the copious amount of research on the design and operation of micromixers, there are few works regarding manufacture technology aimed at implementation beyond academic environments. This work evaluates the viability of xurography as a rapid fabrication tool for the development of ultra-low cost microfluidic technology for extreme Point-of-Care (POC) micromixing devices. By eschewing photolithographic processes and the bulkiness of pumping and enclosure systems for rapid fabrication and passively driven operation, xurography is introduced as a manufacturing alternative for asymmetric split and recombine (ASAR) micromixers. A T-micromixer design was used as a reference to assess the effects of different cutting conditions and materials on the geometric features of the resulting microdevices. Inspection by stereographic and confocal microscopy showed that it is possible to manufacture devices with less than 8% absolute dimensional error. Implementation of the manufacturing methodology in modified circular shape- based SAR microdevices (balanced and unbalanced configurations) showed that, despite the precision limitations of the xurographic process, it is possible to implement this methodology to produce functional micromixing devices. Mixing efficiency was evaluated numerically and experimentally at the outlet of the microdevices with performances up to 40%. Overall, the assessment encourages further research of xurography for the development of POC micromixers.

9 January 2011 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
RGRoberto C. Gallo-Villanueva
Roberto C. Gallo-Villanueva
NJNadia M. Jesús-Pérez
Nadia M. Jesús-Pérez
J.  Israel Martinez LopezJ. Israel Martinez Lopez
J. Israel Martinez Lopez
APAdriana Pacheco
Adriana Pacheco
BLBlanca Lapizco-Encinas
Blanca Lapizco-Encinas

19 March 2019 in Materials
Verified
Journal Article
Open access
PDF file
JAJose Alberto Robles Linares Alvelais
Jose Alberto Robles Linares Alvelais
Erick Ramirez-CedilloErick Ramirez-Cedillo
Erick Ramirez-Cedillo
Hector SillerHector Siller
Hector Siller
CRCiro Rodriguez
Ciro Rodriguez
J.  Israel Martinez LopezJ. Israel Martinez Lopez
J. Israel Martinez Lopez
In this work we present a novel algorithm for generating in-silico biomimetic models of a cortical bone microstructure towards manufacturing biomimetic bone via additive manufacturing. The software provides a tool for physicians or biomedical engineers to develop models of cortical bone that include the inherent complexity of the microstructure. The correspondence of the produced virtual prototypes with natural bone tissue was assessed experimentally employing Digital Light Processing (DLP) of a thermoset polymer resin to recreate healthy and osteoporotic bone tissue microstructure. The proposed tool was successfully implemented to develop cortical bone structure based on osteon density, cement line thickness, and the Haversian and Volkmann channels to produce a user-designated bone porosity that matches within values reported from literature for these types of tissues. Characterization of the specimens using a Scanning Electron Microscopy with Focused Ion Beam (SEM/FIB) and Computer Tomography (CT) revealed that the manufacturability of intricated virtual prototype is possible for scaled-up versions of the tissue. Modeling based on the density, inclination and size range of the osteon and Haversian and Volkmann´s canals granted the development of a dynamic in-silico porosity (13.37–21.49%) that matches with models of healthy and osteoporotic bone. Correspondence of the designed porosity with the manufactured assessment (5.79–16.16%) shows that the introduced methodology is a step towards the development of more refined and lifelike porous structures such as cortical bone. Further research is required for validation of the proposed methodology model of the real bone tissue and as a patient-specific customization tool of synthetic bone.

1 April 2014 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
NLN. Scott Lynn
N. Scott Lynn
J.  Israel Martinez LopezJ. Israel Martinez Lopez
J. Israel Martinez Lopez
MBMarkéta Bocková
Markéta Bocková
PAPavel Adam
Pavel Adam
VCVictor Coello
Victor Coello
JHJiří Homola
Jiří Homola

13 December 2018 in Materials
Verified
Journal Article
Open access
PDF file
JAJose Alberto Robles Linares Alvelais
Jose Alberto Robles Linares Alvelais
JFJ. Obedt Figueroa-Cavazos
J. Obedt Figueroa-Cavazos
CCCristina Chuck-Hernandez
Cristina Chuck-Hernandez
Hector SillerHector Siller
Hector Siller
CRCiro Rodriguez
Ciro Rodriguez
J.  Israel Martinez LopezJ. Israel Martinez Lopez
J. Israel Martinez Lopez
In this work, we assess the effects of sterilization in materials manufactured using additive manufacturing by employing a sterilization technique used in the food industry. To estimate the feasibility of the hydrostatic high-pressure (HHP) sterilization of biomedical devices, we have evaluated the mechanical properties of specimens produced by commercial 3D printers. Evaluations of the potential advantages and drawbacks of Fused Deposition Modeling (FDM), Digital Light Processing (DLP) technology, and Stereolithography (SLA) were considered for this study due to their widespread availability. Changes in mechanical properties due to the proposed sterilization technique were compared to values derived from the standardized autoclaving methodology. Enhancement of the mechanical properties of samples treated with Hydrostatic high-pressure processing enhanced mechanical properties, with a 30.30% increase in the tensile modulus and a 26.36% increase in the ultimate tensile strength. While traditional autoclaving was shown to systematically reduce the mechanical properties of the materials employed and damages and deformation on the surfaces were observed, HHP offered an alternative for sterilization without employing heat. These results suggest that while forgoing high-temperature for sanitization, HHP processing can be employed to take advantage of the flexibility of additive manufacturing technologies for manufacturing implants, instruments, and other devices.