Aims/Introduction: We carried out a multicenter clinical study to investigate whether the decrease in segmental phase angles (PhA values) observed using bioelectrical impedance is useful in screening for diabetes mellitus and monitoring disease progression.Materials and Methods: The segmental PhA values of the four limbs were acquired using multifrequency bioimpedance at 5, 50 and 250 kHz in three clinics. Differences in PhA values between the diabetes and control groups were analyzed using the two‐sample t‐test and analysis of variance (anova). Changes in PhA values with increasing durations of diabetes were analyzed using a moderated mediation model and multivariate linear regression analysis. We recruited 217 participants aged ≥40 years (diabetes 158, controls 59, men 106, women 111, A‐clinic 71, B‐clinic 70 and C‐clinic 76).Results: PhA values at 50 kHz were significantly decreased in people with diabetes (PhA of the right arm in men: t‐value −4.0, P < 0.001; PhA of the right leg in women: t‐value −4.6 P < 0.001), and the difference was partially attributable to the duration of diabetes, as well as aging. Specifically, the mediation effect of the duration of diabetes on the decrease in PhA values was 29.8% in the left arm of men, 53.3% in the right arm of women, and 36.3% in the left arm of both sexes.Conclusions: Phase angle values at 50 kHz decreased in people with diabetes, and the changes were exacerbated as the disease duration increased. Thus, bioimpedance PhA values represent a non‐invasive tool for monitoring the progression of diabetes mellitus.
22 May 2017 in BMC Complementary and Alternative Medicine
Radial pressure pulse wave (RPPW) examination has been a key diagnostic component of traditional Chinese medicine. The objective of this study was to investigate the changes in RPPW along with various hemodynamic variables after acupuncture stimulation and to examine the validity of pulse diagnosis as a modern diagnostic tool. We conducted acupuncture stimulation at both ST36 acupuncture points in 25 healthy volunteers. We simultaneously assessed the RPPW by pulse tonometry; heart rate variability (HRV) by electrocardiogram; photoplethysmogram (PPG) signals, respiration rate, peripheral blood flow velocity and arterial depth by ultrasonography; and cardiac output by impedance cardiography, before, during and after a session of acupuncture stimulation. We observed consistent patterns of increased spectral energy at low frequency (<10 Hz) and pulse power using RPPW examination and in the amplitude and systolic area of the PPG signal during the entire acupuncture session. The low- and high-frequency domains of HRV increased and decreased, respectively, during the acupuncture session. The peripheral blood velocity rose shortly after needle insertion, reached a maximum in the middle of the session and decreased afterwards. The augmentation index (AIX) and pulse transit time (PTT) obtained from RPPW did not change significantly. Acupuncture stimulation at ST36 in healthy subjects increased the peripheral pulse amplitudes (pressure pulse wave (PPW) and PPG), blood flow velocity (ultrasonography) and sympathetic nerve activity (HRV). The lack of changes in the AIX and PTT suggests that the increased pulse amplitudes and blood flow velocity may result from increased cardiac output. Clinical Research Information Service ( KCT0001663 ).
16 March 2020 in IEEE Transactions on Instrumentation and Measurement
Piezo-resistive pressure sensors are widely used for measuring pulse waves of the radial artery. Pulse sensors are generally fabricated with a cover layer because pressure sensors without a cover layer are fragile when they come into direct contact with the skin near the radial artery. However, no study has evaluated the dynamic pulse wave response of pulse sensors depending on the thickness and hardness of the cover layer. This study analyzed the dynamic pulse wave response according to the thickness and hardness of the cover layer and suggests an appropriate thickness and hardness for the design of pulse sensors with semiconductor device-based pressure sensors. Pulse sensors with 6 different cover layers with various thicknesses (0.8 mm, 1 mm, 2 mm) and hardnesses (Shore type A; 30, 43, 49, 71) were fabricated. Experiments for evaluating the dynamic pulse responses of the fabricated sensors were performed using a pulse simulator to transmit the same pulse wave to each of the sensors. To evaluate the dynamic responses of the fabricated pulse sensors, experiments with the pulse sensors were conducted using a simulator that artificially generated a constant pulse wave. The pulse wave simulator consisted of a motorized cam device that generated the artificial radial pulse waveform by adjusting the stroke of the cylindrical air pump and an air tube that conveyed the pulse to the artificial wrist. The amplitude of the measured pulse pressure decreased with increasing thickness and hardness of the cover layer. Normalized waveform analysis showed that the thickness rather than the hardness of the cover layer contributed more to waveform distortion. Analysis of the channel distribution of the pulse sensor with respect to the applied constant dynamic pressure showed that the material of the cover layer had a large effect. In this study, in-line array pulse sensors with various cover layers were fabricated, the dynamic pulse wave responses according to the thickness and the hardness of the cover layer were analyzed, and an appropriate thickness and hardness for the cover layer were suggested. The dynamic pulse wave responses of pulse sensors revealed in this study will contribute to the fabrication of improved pulse sensors and pulse wave analyses.
6 August 2014 in Journal of Micromechanics and Microengineering