3 January 2019 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
TYTae-Heon Yang
Tae-Heon Yang
GJGwanghyun Jo
Gwanghyun Jo
JKJeong-Hoi Koo
Jeong-Hoi Koo
SWSamYong Woo
SamYong Woo
Jaeuk KimJaeuk Kim
Jaeuk Kim
YKYoung-Min Kim
Young-Min Kim
There exists a growing need for a cost-effective, reliable, and portable pulsation simulator that can generate a wide variety of pulses depending on age and cardiovascular disease. For constructing compact pulsation simulator, this study proposes to use a pneumatic actuator based on cam-follower mechanism controlled by a DC motor. The simulator is intended to generate pulse waveforms for a range of pulse pressures and heart beats that are realistic to human blood pulsations. This study first performed in vivo testing of a healthy young man to collect his pulse waveforms using a robotic tonometry system (RTS). Based on the collected data a representative human radial pulse waveform is obtained by conducting a mathematical analysis. This standard pulse waveform is then used to design the cam profile. Upon fabrication of the cam, the pulsatile simulator, consisting of the pulse pressure generating component, pressure and heart rate adjusting units, and the real-time pulse display, is constructed. Using the RTS, a series of testing was performed on the prototype to collect its pulse waveforms by varying the pressure levels and heart rates. Followed by the testing, the pulse waveforms generated by the prototype are compared with the representative, in vivo, pulse waveform. The radial Augmentation Index analysis results show that the percent error between the simulator data and human pulse profiles is sufficiently small, indicating that the first two peak pressures agree well. Moreover, the phase analysis results show that the phase delay errors between the pulse waveforms of the prototype and the representative waveform are adequately small, confirming that the prototype simulator is capable of simulating realistic human pulse waveforms. This study demonstrated that a very accurate radial pressure waveform can be reproduced using the cam-based simulator. It can be concluded that the same testing and design methods can be used to generate pulse waveforms for other age groups or any target pulse waveforms. Such a simulator can make a contribution to the research efforts, such as development of wearable pressure sensors, standardization of pulse diagnosis in oriental medicine, and training medical professionals for pulse diagnosis techniques.

6 August 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JJJae-Hak Jeong
Jae-Hak Jeong
YKYoung-Min Kim
Young-Min Kim
BLBomi Lee
Bomi Lee
JHJunki Hong
Junki Hong
Jaeuk KimJaeuk Kim
Jaeuk Kim
Yong-Hwa ParkYong-Hwa Park
Yong-Hwa Park
This study presents a design and evaluation of a mock circulatory platform, which can reproduce blood pressure and its waveforms to provide palpation experience based on the human cardiovascular physiology. To reproduce the human cardiovascular behavior, especially the blood pressure, the proposed platform includes three major modules: heart, artery and reservoir modules. The heart module reproduces source pressure exerted on the whole system with a controlled time-profile. The artery module consists of a resistance valve to adjust the open area of the vessel and a compliance chamber adjusting the wall stiffness of the ascending aorta. The designed platform was cross validated by comparing the theory with a lumped model, i.e., the windkessel model, the measurements from the mock circulatory platform and the real human body data. As a result, the ventricular and aortic pressure waveforms measured from the designed platform were well matched with those of the actual human body. Parametric studies regarding peripheral resistance and aortic compliance were done for the detailed correlation analysis between human cardiovascular physiology and blood pressure. Since the proposed platform is based on the actual cardiovascular physiology, adjusting the structural parameters of the components can reproduce realistic blood pressure waveforms in a controllable manner. This platform is applicable to blood pressure measurement sensor calibration, palpation training, and haptic feedback.

4 September 2018 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
MJMin-Ho Jun
Min-Ho Jun
YJYoung-Ju Jeon
Young-Ju Jeon
JCJung-Hee Cho
Jung-Hee Cho
YKYoung-Min Kim
Young-Min Kim
Piezo-resistive pressure sensors are widely used for measuring pulse waves of the radial artery. Pulse sensors are generally fabricated with a cover layer because pressure sensors without a cover layer are fragile when they come into direct contact with the skin near the radial artery. However, no study has evaluated the dynamic pulse wave response of pulse sensors depending on the thickness and hardness of the cover layer. This study analyzed the dynamic pulse wave response according to the thickness and hardness of the cover layer and suggests an appropriate thickness and hardness for the design of pulse sensors with semiconductor device-based pressure sensors. Pulse sensors with 6 different cover layers with various thicknesses (0.8 mm, 1 mm, 2 mm) and hardnesses (Shore type A; 30, 43, 49, 71) were fabricated. Experiments for evaluating the dynamic pulse responses of the fabricated sensors were performed using a pulse simulator to transmit the same pulse wave to each of the sensors. To evaluate the dynamic responses of the fabricated pulse sensors, experiments with the pulse sensors were conducted using a simulator that artificially generated a constant pulse wave. The pulse wave simulator consisted of a motorized cam device that generated the artificial radial pulse waveform by adjusting the stroke of the cylindrical air pump and an air tube that conveyed the pulse to the artificial wrist. The amplitude of the measured pulse pressure decreased with increasing thickness and hardness of the cover layer. Normalized waveform analysis showed that the thickness rather than the hardness of the cover layer contributed more to waveform distortion. Analysis of the channel distribution of the pulse sensor with respect to the applied constant dynamic pressure showed that the material of the cover layer had a large effect. In this study, in-line array pulse sensors with various cover layers were fabricated, the dynamic pulse wave responses according to the thickness and the hardness of the cover layer were analyzed, and an appropriate thickness and hardness for the cover layer were suggested. The dynamic pulse wave responses of pulse sensors revealed in this study will contribute to the fabrication of improved pulse sensors and pulse wave analyses.

16 March 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
MJMin-Ho Jun
Min-Ho Jun
YKYoung-Min Kim
Young-Min Kim

17 January 2020 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
JKJeong-Hoi Koo
Jeong-Hoi Koo
JSJeremy M. Schuster
Jeremy M. Schuster
TTTakdanai Tantiyartyanontha
Takdanai Tantiyartyanontha
YKYoung-Min Kim
Young-Min Kim
TYTae-Heon Yang
Tae-Heon Yang
Generating haptic sensations in large touch displays is highly desirable, yet producing them for such application is challenging with conventional haptic actuators used in hand-held devices. This study proposes an electrostatic actuator utilizing frequency beating phenomenon with the goals of generating haptic sensations for large touch sensitive displays (TSDs). Unlike typical electrostatic actuators, the proposed haptic actuator incorporates two high-volt electrodes and a spring supported disk (moveable grounded mass) to enhance the intensity and pattern of haptic sensations. After fabricating a proof-of-concept prototype, its performance was experimentally evaluated by varying the beat frequency and the carrier frequency. Using mock-up LCD panels, a feasibility of the proposed actuator was evaluated for generating meaningful haptic sensations in large TSDs. Testing results show that the prototype generated a variety of unique vibration patterns at varying intensities based on combinations of the two input voltage signals. The results further show that the proposed actuator can produce sufficiently strong vibrotactile feedbacks in mock-up panels, indicating that the proposed electrostatic actuators can be a viable option for providing haptic sensations in large TSDs.

26 May 2016 in Sensors
Verified
Journal Article
Open access
PDF file
MJMin-Ho Jun
Min-Ho Jun
YKYoung-Min Kim
Young-Min Kim
JBJang-Han Bae
Jang-Han Bae
CJChangjin Jung
Changjin Jung
JCJung-Hee Cho
Jung-Hee Cho
YJYoung-Ju Jeon
Young-Ju Jeon
The radial artery pulse is one of the major diagnostic indices used clinically in both Eastern and Western medicine. One of the prominent methods for measuring the radial artery pulse is the piezoresistive sensor array. Independence among channels and an appropriate sensor arrangement are important for effectively assessing the spatial-temporal information of the pulse. This study developed a circular-type seven-channel piezoresistive sensor array using face-down bonding (FDB) as one of the sensor combination methods. The three-layered housing structure that included independent pressure sensor units using the FDB method not only enabled elimination of the crosstalk among channels, but also allowed various array patterns to be created for effective pulse measurement. The sensors were arranged in a circular-type arrangement such that they could estimate the direction of the radial artery and precisely measure the pulse wave. The performance of the fabricated sensor array was validated by evaluating the sensor sensitivity per channel, and the possibility of estimating the blood vessel direction was demonstrated through a radial artery pulse simulator. We expect the proposed sensor to allow accurate extraction of the pulse indices for pulse diagnosis.