Faraj Abuilaiwi

Prof. Faraj Abuilaiwi


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2017 in Journal of Power Sources
Verified
Journal Article
Closed access
Adeel AfzalAdeel Afzal
Adeel Afzal
FAFaraj Abuilaiwi
Faraj Abuilaiwi
AHAmir Habib
Amir Habib
Muhammad AwaisMuhammad Awais
Muhammad Awais
SWSamaila B. Waje
Samaila B. Waje
MHMuataz Hussien
Muataz Hussien

1 January 2010 in Bioinorganic Chemistry and Applications
Verified
Journal Article
Open access
PDF file
MHMuataz Hussien
Muataz Hussien
OBOmer Yehya Bakather
Omer Yehya Bakather
BABassam Al-Tawbini
Bassam Al-Tawbini
ABAlaadin A. Bukhari
Alaadin A. Bukhari
FAFaraj Abuilaiwi
Faraj Abuilaiwi
MFMohamed B. Fettouhi
Mohamed B. Fettouhi
The adsorption mechanism of the removal of lead from water by using carboxylic functional group (COOH) functionalized on the surface of carbon nanotubes was investigated. Four independent variables including pH, CNTs dosage, contact time, and agitation speed were carried out to determine the influence of these parameters on the adsorption capacity of the lead from water. The morphology of the synthesized multiwall carbon nanotubes (MWCNTs) was characterized by using field emission scanning electron microscopy (FESEM) and transmission electron microscopy (TEM) in order to measure the diameter and the length of the CNTs. The diameters of the carbon nanotubes were varied from 20 to 40 nm with average diameter at 24 nm and 10 micrometer in length. Results of the study showed that 100% of lead was removed by using COOH‐MCNTs at pH 7, 150 rpm, and 2 hours. These high removal efficiencies were likely attributed to the strong affinity of lead to the physical and chemical properties of the CNTs. The adsorption isotherms plots were well fitted with experimental data.

1 January 2010 in Journal of Nanomaterials
Verified
Journal Article
Open access
PDF file
MHMuataz Hussien
Muataz Hussien
OBOmer Yahya Bakather
Omer Yahya Bakather
BTBassam Tawabini
Bassam Tawabini
ABAlaadin A. Bukhari
Alaadin A. Bukhari
MKMazen Khaled
Mazen Khaled
FAFaraj Abuilaiwi
Faraj Abuilaiwi
This study was carried out to evaluate the environmental application of modified and nonmodified carbon nanotubes through the experiment removal of chromium trivalent (III) from water. The aim was to find the optimal condition of the chromium (III) removal from water under different treatment conditions of pH, adsorbent dosage, contact time and agitation speed. Multi wall carbon nanotubes (MW‐CNTs) were characterized by field emission scanning electron microscopy (FE‐SEM) and transmission electron microscopy (TEM). The diameter of the carbon nanotubes produced varied from 20–40 nm with average diameter of 24 nm and 10 micrometer in length. Adsorption isotherms were used to model the adsorption behavior and to calculate the adsorption capacity of the absorbents. The results showed that, 18% of chromium (III) removal was achieved using modified carbon nanotubes (M‐CNTs) at pH 7, 150 rpm, and 2 hours for a dosage of 150 mg of CNTs. The removal of Cr (III) is mainly attributed to the affinity of chromium (III) to the physical and chemical properties of the CNTs. The adsorption isotherms plots were well fitted with experimental data.

27 June 2016 in Sensors
Verified
Journal Article
Open access
PDF file
NANedal Abu-Thabit
Nedal Abu-Thabit
Yunusa UmarYunusa Umar
Yunusa Umar
ERElaref Ratemi
Elaref Ratemi
AAAyman Ahmad
Ayman Ahmad
FAFaraj Abuilaiwi
Faraj Abuilaiwi
A new optical pH sensor based on polysulfone (PSU) and polyaniline (PANI) was developed. A transparent and flexible PSU membrane was employed as a support. The electrically conductive and pH-responsive PANI was deposited onto the membrane surface by in situ chemical oxidative polymerization (COP). The absorption spectra of the PANI-coated PSU membranes exhibited sensitivity to pH changes in the range of 4–12, which allowed for designing a dual wavelength pH optical sensor. The performance of the membranes was assessed by measuring their response starting from high pH and going down to low pH, and vice versa. It was found that it is necessary to precondition the sensor layers before each measurement due to the slight hysteresis observed during forward and backward pH titrations. PSU membranes with polyaniline coating thicknesses in the range of ≈100–200 nm exhibited fast response times of <4 s, which are attributed to the porous, rough and nanofibrillar morphology of the polyaniline coating. The fabricated pH sensor was characterized by a sigmoidal response (R2 = 0.997) which allows for pH determination over a wide dynamic range. All membranes were stable for a period of more than six months when stored in 1 M HCl solution. The reproducibility of the fabricated optical pH sensors was found to be <0.02 absorption units after one month storage in 1 M HCl solution. The performance of the optical pH sensor was tested and the obtained pH values were compared with the results obtained using a pH meter device.

30 April 2022 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
SBSheraz Bashir
Sheraz Bashir
AJAkmal Jamil
Akmal Jamil
MKMuhammad Shahzeb Khan
Muhammad Shahzeb Khan
AAAmira Alazmi
Amira Alazmi
FAFaraj Abuilaiwi
Faraj Abuilaiwi
MSMuhammad Shahid
Muhammad Shahid

11 June 2003 in Journal of Applied Polymer Science
Verified
Journal Article
Closed access
PDF file
NINor Azowa Ibrahim
Nor Azowa Ibrahim
WYWan Md Zin Wan Yunus
Wan Md Zin Wan Yunus
FAFaraj Abuilaiwi
Faraj Abuilaiwi
MRMohd Zaki Ab Rahman
Mohd Zaki Ab Rahman
MAMansor Bin Ahmad
Mansor Bin Ahmad
KDKhairul Zaman M. Dahlan
Khairul Zaman M. Dahlan