Keisuke Yasui

Dr. Keisuke Yasui

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2015 in Medical Physics
Verified
Journal Article
Closed access
KYKeisuke Yasui
Keisuke Yasui
TTToshiyuki Toshito
Toshiyuki Toshito
COChihiro Omachi
Chihiro Omachi
YKYoshiaki Kibe
Yoshiaki Kibe
KHKensuke Hayashi
Kensuke Hayashi
JMJun‐Etsu Mizoe
Jun‐Etsu Mizoe

27 November 2017 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
KYKeisuke Yasui
Keisuke Yasui
TTToshiyuki Toshito
Toshiyuki Toshito
COChihiro Omachi
Chihiro Omachi
KHKensuke Hayashi
Kensuke Hayashi
KTKenichiro Tanaka
Kenichiro Tanaka
NHNaoki Hayashi
Naoki Hayashi
In this study, we evaluate dosimetric advantages of using patient‐specific aperture system with intensity‐modulated proton therapy (IMPT) for head and neck tumors at the shallow depth. We used four types of patient‐specific aperture system (PSAS) to irradiate shallow regions less than 4 g/cm2 with a sharp lateral penumbra. Ten head and neck IMPT plans with or without aperture were optimized separately with the same 95% prescription dose and same dose constraint for organs at risk (OARs). The plans were compared using dose volume histograms (DVHs), dose distributions, and some dose indexes such as volume receiving 50% of the prescribed dose (V50), mean or maximum dose (Dmean and Dmax) to the OARs. All examples verified in this study had decreased V50 and OAR doses. Average, maximum, and minimum relative reductions of V50 were 15.4%, 38.9%, and 1.0%, respectively. Dmax and Dmean of OARs were decreased by 0.3% to 25.7% and by 1.0% to 46.3%, respectively. The plans with the aperture over more than half of the field showed decreased V50 or OAR dose by more than 10%. The dosimetric advantage of patient‐specific apertures with IMPT was clarified in many cases. The PSAS has some dosimetric advantages for clinical use, and in some cases, it enables to fulfill dose constraints.

23 January 2019 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
KYKeisuke Yasui
Keisuke Yasui
TTToshiyuki Toshito
Toshiyuki Toshito
COChihiro Omachi
Chihiro Omachi
KHKensuke Hayashi
Kensuke Hayashi
HKHideto Kinou
Hideto Kinou
HOHiroyuki Ogino
Hiroyuki Ogino
The purpose of this study was to propose a verification method and results of intensity‐modulated proton therapy (IMPT), using a commercially available heterogeneous phantom. We used a simple simulated head and neck and prostate phantom. An ionization chamber and radiochromic film were used for measurements of absolute dose and relative dose distribution. The measured doses were compared with calculated doses using a treatment planning system. We defined the uncertainty of the measurement point of the ionization chamber due to the effective point of the chamber and mechanical setup error as 2 mm and estimated the dose variation base on a 2 mm error. We prepared a HU‐relative stopping power conversion table and fluence correction factor that were specific to the heterogeneous phantom. The fluence correction factor was determined as a function of depth and was obtained from the ratio of the doses in water and in the phantom at the same effective depths. In the simulated prostate plan, composite doses of measurements and calculations agreed within ±1.3% and the maximum local dose differences of each field were 10.0%. Composite doses in the simulated head and neck plan agreed within 4.0% and the maximum local dose difference for each field was 12.0%. The dose difference for each field came within 2% when taking the measurement uncertainty into consideration. In the composite plan, the maximum dose uncertainty was estimated as 4.0% in the simulated prostate plan and 5.8% in the simulated head and neck plan. Film measurements showed good agreement, with more than 92.5% of points passing a gamma value (3%/3 mm). From these results, the heterogeneous phantom should be useful for verification of IMPT by using a phantom‐specific HU‐relative stopping power conversion, fluence correction factor, and dose error estimation due to the effective point of the chamber.

1 January 2021 in Physica Medica
Verified
Journal Article
Open access
KYKeisuke Yasui
Keisuke Yasui
COChihiro Omachi
Chihiro Omachi
JNJunya Nagata
Junya Nagata
TTToshiyuki Toshito
Toshiyuki Toshito
HSHidetoshi Shimizu
Hidetoshi Shimizu
NHNaoki Hayashi
Naoki Hayashi
A radiophotoluminescent glass dosimeter (RGD) is widely used in postal audit system for photon beams in Japan. However, proton dosimetry in RGDs is scarcely used owing to a lack of clarity in their response to beam quality. In this study, we investigated RGD response to beam quality for establishing a suitable linear energy transfer (LET)-corrected dosimetry protocol in a therapeutic proton beam. The RGD response was compared with ionization chamber measurement for a 100-225 MeV passive proton beam. LET of the measurement points was calculated by the Monte Carlo method. An LET-correction factor, defined as a ratio between the non-corrected RGD dose and ionization chamber dose, of 1.226×(LET)-0.171 was derived for the RGD response. The magnitude of the LET-dependence of RGD increased with LET; for an LET of 8.2 keV/μm, the RGD under-response was up to 16%. The coefficient of determination, mean difference ± SD of non-corrected RGD dose, residual range-corrected RGD dose, and LET-corrected RGD dose to the ionization chamber are 0.923, 3.7 ± 4.2%, -2.4 ± 7.5%, and 0.04 ± 2.1%, respectively. The LET-corrected RGD dose was within 5% of the corresponding ionization chamber dose at all energies until 200 MeV, where it was 5.3% lower than the ionization chamber dose. A corrected LET-dependence of RGD using a correction factor based on a power function of LET and precise dosimetric verification close to the maximum LET were realized here. We further confirmed establishment of an accurate postal audit under various irradiation conditions.

2 August 2021 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
JNJunya Nagata
Junya Nagata
KYKeisuke Yasui
Keisuke Yasui
COChihiro Omachi
Chihiro Omachi
TTToshito Toshiyuki
Toshito Toshiyuki
HSHidetoshi Shimizu
Hidetoshi Shimizu
NHNaoki Hayashi
Naoki Hayashi
A radiophotoluminescent glass dosimeter (RGD) is used for a postal audit of a photon beam because of its various excellent characteristics. However, it has not been used for scanning proton beams because its response characteristics have not been verified. In this study, the response of RGD to scanning protons was investigated to develop a dosimetry protocol using the linear energy transfer (LET)‐based correction factor. The responses of RGD to four maximum‐range‐energy‐pattern proton beams were verified by comparing it with ionization chamber (IC) dosimetry. The LET at each measurement depth was calculated via Monte Carlo (MC) simulation. The LET correction factor () was the ratio between the uncorrected RGD dose () and the IC dose at each measurement depth. can be represented as a function of LET using the following equation: . showed a linear under‐response with increasing LET, and the maximum dose difference between the IC dose and was 15.2% at an LET of 6.07 keV/μm. The LET‐based correction dose () conformed within 3.6% of the IC dose. The mean dose difference (±SD) of and was –2.5 ± 6.9% and 0.0 ± 1.6%, respectively. To achieve accurate dose verification for scanning proton beams using RGD, we derived a linear regression equation based on LET. The results show that with appropriate LET correction, RGD can be used for dose verification of scanning proton beams.

18 September 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KYKeisuke Yasui
Keisuke Yasui
YSYasunori Saito
Yasunori Saito
AIAzumi Ito
Azumi Ito
MDMomoka Douwaki
Momoka Douwaki
SOShuta Ogawa
Shuta Ogawa
NHNaoki Hayashi
Naoki Hayashi
Deep learning-based CT image reconstruction (DLR) is a state-of-the-art method for obtaining CT images. This study aimed to evaluate the usefulness of DLR in radiotherapy. Data were acquired using a large-bore CT system and an electron density phantom for radiotherapy. We compared the CT values, image noise, and CT value-to-electron density conversion table of DLR and hybrid iterative reconstruction (H-IR) for various doses. Further, we evaluated three DLR reconstruction strength patterns (Mild, Standard, and Strong). The variations of CT values of DLR and H-IR were large at low doses, and the difference in average CT values was insignificant with less than 10 HU at doses of 100 mAs and above. DLR showed less change in CT values and smaller image noise relative to H-IR. The noise-reduction effect was particularly large in the low-dose region. The difference in image noise between DLR Mild and Standard/Strong was large, suggesting the usefulness of reconstruction intensities higher than Mild. DLR showed stable CT values and low image noise for various materials, even at low doses; particularly for Standard or Strong, the reduction in image noise was significant. These findings indicate the usefulness of DLR in treatment planning using large-bore CT systems.