Toshiyuki Toshito

Dr. Toshiyuki Toshito

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 June 2016 in Australasian Physics & Engineering Sciences in Medicine
Verified
Journal Article
Closed access
PDF file
TTToshiyuki Toshito
Toshiyuki Toshito
COChihiro Omachi
Chihiro Omachi
YKYoshiaki Kibe
Yoshiaki Kibe
HSHiroyuki Sugai
Hiroyuki Sugai
KHKensuke Hayashi
Kensuke Hayashi
JMJun’eTsu Mizoe
Jun’eTsu Mizoe

1 December 2015 in Medical Physics
Verified
Journal Article
Closed access
KYKeisuke Yasui
Keisuke Yasui
TTToshiyuki Toshito
Toshiyuki Toshito
COChihiro Omachi
Chihiro Omachi
YKYoshiaki Kibe
Yoshiaki Kibe
KHKensuke Hayashi
Kensuke Hayashi
JMJun‐Etsu Mizoe
Jun‐Etsu Mizoe

11 April 2023 in Physics and Imaging in Radiation Oncology
Verified
Journal Article
Open access
YZYe Zhang
Ye Zhang
PTPetra Trnkova
Petra Trnkova
TTToshiyuki Toshito
Toshiyuki Toshito
BHBen Heijmen
Ben Heijmen
CRChristian Richter
Christian Richter
AKAntje Knopf
Antje Knopf
Organ motion compromises accurate particle therapy delivery. This study reports on the practice patterns for real-time intrafractional motion-management in particle therapy to evaluate current clinical practice and wishes and barriers to implementation. An institutional questionnaire was distributed to particle therapy centres worldwide (7/2020–6/2021) asking which type(s) of real-time respiratory motion management (RRMM) methods were used, for which treatment sites, and what were the wishes and barriers to implementation. This was followed by a three-round DELPHI consensus analysis (10/2022) to define recommendations on required actions and future vision. With 70 responses from 17 countries, response rate was 100% for Europe (23/23 centres), 96% for Japan (22/23) and 53% for USA (20/38). Of the 68 clinically operational centres, 85% used RRMM, with 41% using both rescanning and active methods. Sixty-four percent used active-RRMM for at least one treatment site, mostly with gating guided by an external marker. Forty-eight percent of active-RRMM users wished to expand or change their RRMM technique. The main barriers were technical limitations and limited resources. From the DELPHI analysis, optimisation of rescanning parameters, improvement of motion models, and pre-treatment 4D evaluation were unanimously considered clinically important future focus. 4D dose calculation was identified as the top requirement for future commercial treatment planning software. A majority of particle therapy centres have implemented RRMM. Still, further development and clinical integration were desired by most centres. Joint industry, clinical and research efforts are needed to translate innovation into efficient workflows for broad-scale implementation.

28 April 2023 in Physics and Imaging in Radiation Oncology
Verified
Journal Article
Open access
PTPetra Trnkova
Petra Trnkova
YZYe Zhang
Ye Zhang
TTToshiyuki Toshito
Toshiyuki Toshito
BHBen Heijmen
Ben Heijmen
CRChristian Richter
Christian Richter
JBJenny Bertholet
Jenny Bertholet
Anatomical changes may compromise the planned target coverage and organs-at-risk dose in particle therapy. This study reports on the practice patterns for adaptive particle therapy (APT) to evaluate current clinical practice and wishes and barriers to further implementation. An institutional questionnaire was distributed to PT centres worldwide (7/2020–6/2021) asking which type of APT was used, details of the workflow, and what the wishes and barriers to implementation were. Seventy centres from 17 countries participated. A three-round Delphi consensus analysis (10/2022) among the authors followed to define recommendations on required actions and future vision. Out of the 68 clinically operational centres, 84% were users of APT for at least one treatment site with head and neck being most common. APT was mostly performed offline with only two online APT users (plan-library). No centre used online daily re-planning. Daily 3D imaging was used for APT by 19% of users. Sixty-eight percent of users had plans to increase their use or change their technique for APT. The main barrier was “lack of integrated and efficient workflows”. Automation and speed, reliable dose deformation for dose accumulation and higher quality of in-room volumetric imaging were identified as the most urgent task for clinical implementation of online daily APT. Offline APT was implemented by the majority of PT centres. Joint efforts between industry research and clinics are needed to translate innovations into efficient and clinically feasible workflows for broad-scale implementation of online APT.

21 February 2025 in Medical Physics
Verified
Journal Article
Open access
PAPedro Arce
Pedro Arce
JAJay W. Archer
Jay W. Archer
LALorenzo Arsini
Lorenzo Arsini
ABAlexander Bagulya
Alexander Bagulya
DBDavid Bolst
David Bolst
DWDennis H. Wright
Dennis H. Wright
Background: Geant4, a Monte Carlo Simulation Toolkit extensively used in bio‐medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4‐Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4‐Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose: In this work, we describe the evolution of the G4‐Med benchmarking system. Methods: The G4‐Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set‐ups. New tests concern the benchmarking of Geant4‐DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a source, dosimetry for external x‐ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results: In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x‐ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x‐ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study ( G4EmLivermorePhysics , G4EmStandardPhysics_option3 , and G4EmStandardPhysics_option4 ). These differences will be studied in an in‐depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions: Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4 , for hadrontherapy applications. The Geant4‐DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

1 July 2017 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
TTT. Taya
T. Taya
JKJun Kataoka
Jun Kataoka
AKA. Kishimoto
A. Kishimoto
LTL. Tagawa
L. Tagawa
SMS. Mochizuki
S. Mochizuki
NKNaoki Kawachi
Naoki Kawachi