Chokri Ben Salah

Prof. Dr. Chokri Ben Salah

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2010 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
CSChokri Ben Salah
Chokri Ben Salah
MOMohamed Ouali
Mohamed Ouali
This work describes a new control strategy for active energy flow in a hybrid photovoltaic (PV) system. The method introduces an online energy management by a hierarchical fuzzy controller between energy sources that consist of a photovoltaic panel (PVP), the battery and the load. The fuzzy logic controller has been developed for power splitting between PVP and battery, and it makes decision to choose the switching chain rules and corresponding controller. Simulation test results illustrate improvement in the operation's efficiency of online state of the switches and the battery's state of charge (SOC) has been maintained at a reasonable level. Copyright © 2010 John Wiley & Sons, Ltd.

14 May 2021 in Energies
Verified
Journal Article
Open access
PDF file
RFRuben Zieba Falama
Ruben Zieba Falama
FWFelix Ngangoum Welaji
Felix Ngangoum Welaji
ADAbdouramani Dadjé
Abdouramani Dadjé
Virgil DUMBRAVAVirgil DUMBRAVA
Virgil DUMBRAVA
NDNoël Djongyang
Noël Djongyang
SYSerge Doka Yamigno
Serge Doka Yamigno
A techno-economic study of a hybrid PV/Battery/Grid-connected system for energy supply is carried out in this paper to respond to the problem of electrical load shedding. An optimal design of the system is realized thanks to a double-objective optimization based on a proposed operational strategy of the system and on Firefly Algorithm (FA). The system is designed for household energy supply in three different towns of the northern part of Cameroon. For different LPSP (Loss of Power Supply Probability), the double objective simulation determines the optimal configurations of the system with their related cost. The optimal and reliable PV/Battery subsystem configuration corresponding to LPSP of 0% obtained for one household is composed for the towns of Maroua and Garoua by 8 PV modules and a battery capacity of 11.304 kWh with 1-day autonomy. For the town of Ngaoundéré, it is composed by 10 PV modules and battery capacity of 11.304 kWh with 1-day autonomy. The related investment costs corresponding to these optimal configurations are USD 6225.6 for Maroua and Garoua and USD 7136.6 for Ngaoundéré. The great proportion of the monthly energy demand consumed by the load is provided by the PV/Battery system. The monthly PV/Battery energy represents 60.385% to 72.546% of the load consumed in Maroua, 58.371% to 71.855% of the load consumed in Garoua, and 61.233% to 74.160% of the load consumed in Ngaoundéré. The annual main grid energy consumed for one household is 1299.524 kWh in Maroua, 1352.818 kWh in Garoua, and 1260.876 kWh in Ngaoundéré. Moreover, the annual PV/Battery energy consumed for one household is 1580.730 kWh in Maroua, 1527.815 kWh in Garoua, and 1619.530 kWh in Ngaoundéré. Thus, the PV/Battery system, by reducing the grid energy consumption, acts as the principal source of energy of the whole system. The time the PV/Battery/Grid-connected system needs to be economically more advantageous than the electric grid without blackouts is 17 years for Maroua and 18 years for both Garoua and Ngaoundéré. It is demonstrated in this paper that the hybrid PV/Battery/Grid-connected system is an effective solution for electrical load shedding in sub-Saharan zones. This system is very useful for grid energy consumption reduction. For a long-term investment, the PV/Battery/Grid-connected system is more economically advantageous than the main grid alone.

19 July 2021 in Transactions of the Institute of Measurement and Control
Verified
Journal Article
Closed access
PDF file
FNFerdaws Ben Naceur
Ferdaws Ben Naceur
CSChokri Ben Salah
Chokri Ben Salah
ATAchraf Jabeur Telmoudi
Achraf Jabeur Telmoudi
MMMohamed Ali Mahjoub
Mohamed Ali Mahjoub
Renewable energy plays a very important role in solving energy problems, and solar energy is one of the most important renewable sources, especially in sunny countries. This paper deals with two problems: The first one is about optimal sizing in a photovoltaic panel (PVP)-battery system, and the second consists in energy management in smart grids. To achieve the first objective, an adaptive neuro-fuzzy inference system (ANFIS) estimation algorithm is developed in order to estimate a database of instantaneous photovoltaic power. The estimated instantaneous photovoltaic power is used in an optimal algorithm to size a PVP-battery power station to supply a 1.5 kW AC load. For the second objective, a deep learning forecasting algorithm is realized to estimate the smart grid parameters so as to optimize the consumption energy. All results are checked carrying out Matlab simulation using real weather data. The simulation results give a good performance of our proposed sizing and management systems.

12 December 2023 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Open access
PDF file
MCMohamed Haikel Haikel CHEHAB
Mohamed Haikel Haikel CHEHAB
CSChokri Ben Salah
Chokri Ben Salah
RFRuben Zieba Falama
Ruben Zieba Falama
MTMehdi Tlija
Mehdi Tlija
Abdelhamid RabhiAbdelhamid Rabhi
Abdelhamid Rabhi
Nowadays, microgrids (MGs) are receiving a lot of attention. In an economical MG, the battery energy storage system (BESS) plays an important role. One of the biggest challenges in MGs is the optimal choice of the BESS that can lead to better performance of the MG, which will be more flexible, efficient, and effective than traditional power systems. In this paper, we present the modeling and simulation of different energy storage systems including Li-ion, lead-acid, nickel cadmium (Ni-Cd), nickel-metal hybrid (Ni-Mh), and supercapacitor (SC), for renewable energy applications, and more specifically for MGs. The results of simulation show that Li-ion batteries have a better response time than lead-acid batteries, Ni-Cd batteries, and Ni-Mh batteries and thus are more suitable for combination with supercapacitors. Li-ion batteries are the best option for fast-charging applications in MGs. The discharge phase ends with SOC ≤ ±94%, SOC ≤ ±95%, SOC = 95%, SOC < 95%, and SOC < 60%, respectively, for Li-ion, lead-acid, Ni-Cd, Ni-Mh, and supercapacitor. Moreover, the use of the battery management system (BMS) can significantly improve the performance of BESS, leading to higher levels of SOC and longer life span. The obtained results have shown that with an optimization algorithm for energy storage systems, more specifically for the battery-charging mode, the response time of BESSs can be further improved. The effect of ambient temperature has also been investigated on the functional capacities of the batteries. The obtained results demonstrated that extreme temperatures (80°C to −80°C) have a significant impact on battery performance and capacity, especially for Li-ion batteries, with a drop in capacity of up to 50% at −40°C. This highlights the importance of considering the ambient temperature in the design and operation of MGs. Overall, our study provides valuable insights into the optimal selection of BESS and the impact of ambient temperature on their performance, which can help in the development of more efficient and reliable MGs.

22 June 2022 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Open access
PDF file
RFRuben Zieba Falama
Ruben Zieba Falama
YAYaouba
Yaouba
FMFrancis-Daniel Menga
Francis-Daniel Menga
MSMarcel Hamda Soulouknga
Marcel Hamda Soulouknga
FMFabrice Kwefeu Mbakop
Fabrice Kwefeu Mbakop
CSChokri Ben Salah
Chokri Ben Salah
This paper focused on a techno-economic study of a standalone PV/battery system for electrical energy supply. For a particular case study in Cameroon, the system is optimally designed thanks to a double-objective firefly optimization algorithm, based on a defined operational strategy. The two objective functions simulated simultaneously using FA are: the cost of energy (COE) function and the function defining the loss of power supply probability (LPSP). Different optimal configurations of the system have been obtained on the Pareto front with respect to their LPSP. For a total load demand of 20196.7 kWh, the lowest cost configuration with LPSP of 0% is composed by a number of 63 modules and a battery capacity of 370.295 kWh. The related COE is 0.2587 $/kWh, corresponding to a total net present cost of 87422 $. However with this configuration, the energy of batteries could not be able solely to respond to the energy demand for 3 continuous days. In that case, the increase of the PV power production (by increasing the number of PV modules) could allow to the batteries to fulfil this deficiency. But this solution increases the investment cost to up to 11.17%, considering a system with 80 PV modules. Another solution consists in reducing the size of the battery bank to avoid its unnecessary oversizing. In this case, the COE and the system investment cost reduce to up to 28.77% for 1 day batteries’ autonomy considered. The obtained results have demonstrated that the cost of a PV/battery system is mostly influenced by the batteries’ size, while the system reliability is mostly related to the PV size.

15 July 2024 in Energies
Verified
Journal Article
Open access
PDF file
GBGaith Baccouche
Gaith Baccouche
MCMohamed Haikel Haikel CHEHAB
Mohamed Haikel Haikel CHEHAB
CSChokri Ben Salah
Chokri Ben Salah
MTMehdi Tlija
Mehdi Tlija
Abdelhamid RabhiAbdelhamid Rabhi
Abdelhamid Rabhi
The design and integration of intelligent energy management systems in hybrid electric vehicle (EV) charging stations, leveraging industry 4.0 and renewable energy sources, is crucial for advancing sustainability, efficiency, and technological development. The innovative hybrid EV charging station described in this study uses a combination of fuel cells, batteries, and solar panels that run at 14 amps a piece at 240 volts. The system consists of five essential components that work together to transfer power wirelessly: an EV battery bank, a boost converter, an HF inverter, transfer coils, and a power supply. Two crucial phases make up the optimization process. In phase 1, the boost converter’s maximum power point is tracked and optimized to generate the most power possible by varying the duty cycle between 10% and 90%. In phase 2, the HF uses a class ϕ2 inverter at 30 MHz to synchronize with the resonant frequency of wireless power transfer coils. Zero-voltage switching is used by a digital signal processor card to carry out control for effective operations. By utilizing hybrid sources to optimize power transmission, this design improves the sustainability of EV charging options.