The study focuses on the evaluation of global solar radiation on a horizontal level. The estimate of the solar layer was made on the basis of mathematical model obtained from the relations of Angstrom–Prescott, Allen and Sabbagh. The different proposed models have been implemented by using MATLAB and Excel. The models were evaluated using MPE, NSE, RMSE and MBE. The outcome of this shows that the Angstrom–Prescott model is the most suitable for the calculation of global solar radiation in the sites of Mongo with values of 5.887 kWh/m2. For the site of Bokoro, the Allen model is the most adapted for the calculation of global solar radiation which is 5.872 kWh/m2. On the other hand, the Sabbagh model is appropriate for the sites of Abeche, N’Djamena, Ati and Moussoro with respective values of 6.354, 5.742, 5.523 and 6.126 kWh/m2. The obtained results show that the Sahelian zone of Chad has a good solar potential and consequently suitable for the exploitation of solar energy systems.
31 December 2022 in Jurnal Elektronika dan Telekomunikasi
Sustainable future development relies on solar radiation, which is the main source of renewable energy. Thus, in this article, the monthly average global solar irradiation of four sites in the Sudanian zone region of Chad is estimated using different empirical models. The data used in this study were collected at the General Directorate of Meteorology of Chad. The reliability and accuracy of six models estimating global solar radiation were validated and compared by statistical indicators identifying the most accurate model. The results obtained show that the Allen model has the best performance for the Moundou site (5.760 kWh/m²/d, R2=0.843), the Angstrom Prescott model for the Sarh sites (5.658 kWh/m²/d, R2=0.805) and Pala (5.793 kWh/m²/d, R²=0.889), the Sabbagh model for the Bongor site (5.657 kWh/m²/d, R²=0.888). These models are validated against NASA data. The results show that the Sudanian zone of Chad has good solar potential and is therefore suitable for possible exploitation.
22 June 2022 in International Transactions on Electrical Energy Systems
This paper focused on a techno-economic study of a standalone PV/battery system for electrical energy supply. For a particular case study in Cameroon, the system is optimally designed thanks to a double-objective firefly optimization algorithm, based on a defined operational strategy. The two objective functions simulated simultaneously using FA are: the cost of energy (COE) function and the function defining the loss of power supply probability (LPSP). Different optimal configurations of the system have been obtained on the Pareto front with respect to their LPSP. For a total load demand of 20196.7 kWh, the lowest cost configuration with LPSP of 0% is composed by a number of 63 modules and a battery capacity of 370.295 kWh. The related COE is 0.2587 $/kWh, corresponding to a total net present cost of 87422 $. However with this configuration, the energy of batteries could not be able solely to respond to the energy demand for 3 continuous days. In that case, the increase of the PV power production (by increasing the number of PV modules) could allow to the batteries to fulfil this deficiency. But this solution increases the investment cost to up to 11.17%, considering a system with 80 PV modules. Another solution consists in reducing the size of the battery bank to avoid its unnecessary oversizing. In this case, the COE and the system investment cost reduce to up to 28.77% for 1 day batteries’ autonomy considered. The obtained results have demonstrated that the cost of a PV/battery system is mostly influenced by the batteries’ size, while the system reliability is mostly related to the PV size.