Jungsu Kim

Prof. Jungsu Kim

Deagu Health College
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 September 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
SLSang-Kyung Lee
Sang-Kyung Lee
JKJungsu Kim
Jungsu Kim
SYSang-wook Yoon
Sang-wook Yoon
JKJung Min Kim
Jung Min Kim
The aim of this study was to determine the conversion factors for the effective dose (ED) per dose length product (DLP) for various computed tomography (CT) protocols based on the 2007 recommendations of the International Commission on Radiological Protection (ICRP). CT dose data from 369 CT scanners and 13,625 patients were collected through a nationwide survey. Data from 3793 patients with a difference in height within 5% of computational human phantoms were selected to calculate ED and DLP. The anatomical CT scan ranges for 11 scan protocols (adult-10, pediatric-1) were determined by experts, and scan lengths were obtained by matching scan ranges to computational phantoms. ED and DLP were calculated using the NCICT program. For each CT protocol, ED/DLP conversion factors were calculated from ED and DLP. Estimated ED conversion factors were 0.00172, 0.00751, 0.00858, 0.01843, 0.01103, 0.02532, 0.01794, 0.02811, 0.02815, 0.02175, 0.00626, 0.00458, 0.00308, and 0.00233 mSv∙mGy−1∙cm−1 for the adult brain, intra-cranial angiography, C-spine, L-spine, neck, chest, abdomen and pelvis, coronary angiography, calcium scoring, aortography, and CT examinations of pediatric brain of <2 years, 4–6 years, 9–11 years, and 13–15 years, respectively. We determined ED conversion factors for 11 CT protocols using CT data obtained from a nationwide survey in Korea and Monte Carlo-based dose calculations.

29 September 2022 in Tomography
Verified
Journal Article
Open access
PDF file
SNSora Nam
Sora Nam
HPHyemin Park
Hyemin Park
SKSoonmu Kwon
Soonmu Kwon
PCPyong-Kon Cho
Pyong-Kon Cho
YYYongsu Yoon
Yongsu Yoon
JKJungsu Kim
Jungsu Kim
Background: In 2021, the Korean government proposed a new CT diagnostic reference level. This study performed a nationwide survey and developed new DRLs and AD for 13 common CT examinations. We compared other countries’ DRLs for CT examinations. Methods: This study investigated the CTDIvol and DLP of the 12 types of CT protocols for adults and brain CT protocol for pediatrics. A total of 7829 CT examinations were performed using 225 scanners. We defined the DRLs values in the distribution of radiation exposure levels to determine the nationwide patient dose and distribution status of the dose. Results: This study showed that the new Korean national CT DRLs are slightly higher or similar to those of previous surveys and are similar or lower than those of other countries. In some protocols, although the DLP value increased, the CTDIvol decreased; therefore, it can be concluded that the patient’s dose in CT examinations was well managed. Conclusions: The new CT DRLs were slightly higher than or similar to that of the previous survey and were evaluated to be similar or lower than CT DRLs of other countries. These DRLs will be used for radiation optimization and effective dose calculation for an individual.

YYYongsu Yoon
Yongsu Yoon
HPHyemin Park
Hyemin Park
JKJung Min Kim
Jung Min Kim
JKJungsu Kim
Jungsu Kim
YRYOUNGHOON ROH
YOUNGHOON ROH
JMJunji Morishita
Junji Morishita
In radiography, the exposure index (EI), as per the International Electrotechnical Commission standard, depends on the incident beam quality and exposure dose to the digital radiography system. Today automatic exposure control (AEC) systems are commonly employed to obtain the optimal image quality. An AEC system can maintain a constant incident exposure dose on the image receptor regardless of the patient thickness. In this study, we investigated the relationship between body thickness, entrance surface dose (ESD), EI, and the exposure indicator (S value) with the aim of using EI as the dose optimization tool in digital chest radiography (posterior–anterior and lateral projection). The exposure condition from the Korean national survey for determining diagnostic reference levels and two digital radiography systems (photostimulable phosphor plate and indirect flat panel detector) were used. As a result, ESD increased as the phantom became thicker with constant exposure indicator, which indicates similar settings to an AEC system, but the EI indicated comparatively constant values without following the tendency of ESD. Therefore, body thickness should be considered under the AEC system for introducing EI as the dose optimization tool in digital chest radiography.

12 October 2019 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
JKJungsu Kim
Jungsu Kim
BLBong-Ki Lee
Bong-Ki Lee
DRDong Ryeol Ryu
Dong Ryeol Ryu
KCKwang Jin Chun
Kwang Jin Chun
HCHyun-Hee Choi
Hyun-Hee Choi
BCByung-Ryul Cho
Byung-Ryul Cho
Interventional cardiology procedures can involve relatively high radiation doses compared to general radiography. During coronary angiography (CAG) and percutaneous transluminal coronary intervention (PCI), the same area is exposed to radiation for a long period. In this study, radiation exposure data of 1071 examinations in Korean hospitals were collected, and the achievable dose (AD) and diagnostic reference levels (DRLs) in actual medical practice for two types of interventional cardiology procedures in Korea were established. In CAG, 75th percentile DRLs and AD of the total kerma-area product were 47.0 and 33.1 Gy·cm 2, respectively. In PCI, those values were 171.3 and 102.6 Gy·cm2, respectively. This is the first study to introduce the DRLs for cardiovascular interventional procedures in Korea. These results will help optimise the interventional cardiology procedures for Korean cardiac centres.

YRYOUNGHOON ROH
YOUNGHOON ROH
JKJungsu Kim
Jungsu Kim
HPHyemin Park
Hyemin Park
JKJung Min Kim
Jung Min Kim
DRDongryeol Ryu
Dongryeol Ryu
YYYongsu Yoon
Yongsu Yoon
Cardiac angiography to visualize the cardiac coronary artery for lesions causes a lot of radiation exposure dose to the interventional cardiologist. We evaluated the occupational radiation exposure to the interventional cardiologist based on changes to the angle of the X-ray tube used in cardiac angiography and calculated the conversion factor for effective dose in this study. To evaluate the occupational radiation exposure resulting from scattered radiation to interventional cardiologists, organ doses for eyeball, thyroid, and heart were calculated using Monte Carlo simulation with korean typical man(KTMAN) phantom at the left anterior oblique (LAO)30/cranial (CRAN)30, CRAN40, right anterior oblique (RAO)30/CRAN30, RAO30/caudal(CAUD)20, CAUD39, LAO40/CAUD35, and LAO40 positions in the femoral and the radial artery puncture. In this study, analysis of the different angles showed the highest radiation exposure on LAO30/CRAN30 and CRAN40 position, which were 150.65% and 135.3%, respectively, compared to AP angles. Therefore, to reduce occupational dose for interventional cardiologists, it is recommended that radiation protection, such as using radiation shield and personal protective equipment (PPE), be used at LAO30/CRAN30 and CRAN40 angulation, and the conversion factor for calculating the organ dose received by the interventional cardiologists based on patient dose can be applied for improved occupational dose management.

28 April 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
JKJungsu Kim
Jungsu Kim
BLBong-Ki Lee
Bong-Ki Lee
DRDong-Ryeol Ryu
Dong-Ryeol Ryu
KCKwangjin Chun
Kwangjin Chun
HKHo-Seok Kwon
Ho-Seok Kwon
BCByung-ryul Cho
Byung-ryul Cho
Medical radiation exposure is a significant concern for interventional cardiologists (IC). This study was aimed at estimating the radiation exposure of IC operators and assistants in real clinical practice. The radiation exposure of the operator and assistant was evaluated by conducting two types of procedures via coronary angiography (CAG) and percutaneous coronary intervention (PCI) on 1090 patients in 11-cardiovascular centers in Korea. Radiation exposure was measured using an electronic personal dosimeter (EPD). EPD were attached at 3 points on each participant: on the apron on the left anterior chest (A1), under the apron on the sternum (A2), and on the thyroid shield (T). Average radiation exposure (ARE) of operators at A1, A2, and T was 19.219 uSv, 4.398 uSv, and 16.949 uSv during CAG and 68.618 uSv, 15.213 uSv, and 51.197 uSv during PCI, respectively. ARE of assistants at A1, A2, and T was 4.941 uSv, 0.860 uSv, and 5.232 uSv during CAG and 20.517 uSv, 4.455 uSv, and 16.109 uSv during PCI, respectively. AED of operator was 3.4 times greater during PCI than during CAG.