Mirko Resan

Prof. Dr. Mirko Resan


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2015 in Health and Quality of Life Outcomes
Verified
Journal Article
Open access
PDF file
BKBojan Kovac
Bojan Kovac
MVMiroslav Vukosavljevic
Miroslav Vukosavljevic
JKJelena Kovac
Jelena Kovac
MRMirko Resan
Mirko Resan
GTGoran Trajkovic
Goran Trajkovic
AGAnita Grgurevic
Anita Grgurevic
To test the validity and reliability of the Serbian version of the interviewer-administered format of the National Eye Institute Visual Functioning Questionnaire (NEI VFQ-25). The Serbian version of NEI VFQ-25 was translated in accordance with standard methods that have been adopted internationally. In order to assess the reliability and validity of the translated NEI VFQ-25, we used a sample of 105 patients with four different chronic ocular diseases. Cronbach’s alpha coefficient was used to assess internal consistency for each subscale. To assess test–retest reliability, intraclass correlation coefficients were used. The test–retest data were obtained from clinically stable patients with age-related cataracts, in surveys performed 2 weeks apart. Rasch analysis was also applied as a modern methods of psychometric assessment of the questionnaire. Four groups of patients were studied and the most prevalent were patients with cataract 40 (38.1 %), followed by diabetic retinopathy 31 (29.5 %), age related macular degeneration 22 (21.0 %) and glaucoma 12 (11.4 %). The overall index score on the NEI VFQ-25 ranged from 65.3 to 67.8 with a mean of 67.4 ± 15.0. Cronbach’s alpha coefficient (index of internal consistency reliability) ranged from 0.643 to 0.889 for the subscales. Evaluation of the validity of the Serbian version of NEI VFQ-25 is presented in the multi-trait–multi-method matrix and all items passed the convergent and discriminant validity tests. Rasch analysis showed a good measurement precision, but also demonstrated misfitting items and multidimensionality of the questionnaire. Although traditional validation method indicates that the Serbian version of NEI VFQ-25 is a valid and reliable instrument for the assessment of vision specific QoL in Serbian populations aged 40 years or older, Rasch analysis revealed a substantial weakness of the questionnaire that should be taken into consideration when interpreting the results.

8 July 2021 in Medicina
Verified
Journal Article
Open access
PDF file
Bojan PajicBojan Pajic
Bojan Pajic
BPBrigitte Pajic-Eggspuehler
Brigitte Pajic-Eggspuehler
CRChristian Rathjen
Christian Rathjen
MRMirko Resan
Mirko Resan
Zeljka CvejicZeljka Cvejic
Zeljka Cvejic
The power density of femtosecond lasers and exposure time to the tissue are crucial for a successful procedure in terms of safety and precision. The reduction of the pulse duration allows reducing the quantity of the energy to be delivered to the tissue for disruption with strongly diminished mechanical and thermal collateral damage. The cutting effect of ultra-short pulses is very precise, minimally traumatic, safe, and predictable. Future developments will lead to further energy reductions to achieve optical breakdowns. However, the pulse length cannot be shortened arbitrarily because below 100 fs nonlinear effects can change the process in an unfavorable way. Compared to manual-conventional cataract surgery, femtosecond laser-assisted cataract surgery (FLACS) shows many advantages in clinical application, especially with regard to precision and tissue protection. The femtosecond laser has become particularly important and has made the overall procedure safer when we deal with complex cataract cases such as subluxated lenses. We provide an overview of the evolution of femtosecond laser technology for use in refractive and cataract surgeries. This article describes the advantages of available laser platforms with ultrashort pulses and mainly focuses on the technical and physical backgrounds of ophthalmic surgery technologies.

6 August 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Bojan PajicBojan Pajic
Bojan Pajic
MRMirko Resan
Mirko Resan
BPBrigitte Pajic-Eggspuehler
Brigitte Pajic-Eggspuehler
HMHorace Massa
Horace Massa
Zeljka CvejicZeljka Cvejic
Zeljka Cvejic
Background: The aim of the study is to investigate whether the circadian IOP rhythm can be influenced by combined cataract surgery with high frequency deep sclerotomy (HFDS) and whether intraocular pressure (IOP) can be significantly reduced by HFDS. Methods: In our study 10 patients were included, in whom 24 h IOP monitoring was installed before and after HFDS/cataract surgery using a Triggerfish. HFDS is a minimally invasive glaucoma surgery (MIGS). Results: After performed HFDS combined with cataract surgery, the IOP was reduced from 27.7 ± 2.11 mmHg to 14.4 ± 2.59 mmHg, which is highly significant (p < 0.001). The contact lens sensor (CLS) cosinor analysis pre- and postoperatively showed that the circadian rhythm is not influenced by the surgery, i.e., the circadian IOP rhythm did not show significant differences before and after surgery. Conclusions: HFDS combined with cataract surgery is a potent surgical method that can significantly reduce the IOP. However, the circadian rhythm cannot be changed by the surgery. The acrophase remained during the night in all patients.

27 December 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Bojan PajicBojan Pajic
Bojan Pajic
Zeljka CvejicZeljka Cvejic
Zeljka Cvejic
KMKaweh Mansouri
Kaweh Mansouri
MRMirko Resan
Mirko Resan
RAReto Allemann
Reto Allemann
Background: The efficiency and safety of primary open-angle glaucoma with high-frequency deep sclerotomy (HFDS) combined with cataract surgery has to be investigated. Methods: Right after cataract surgery, HFDS was performed ab interno in 205 consecutive patients with open angle glaucoma. HFDS was performed with a custom-made high-frequency disSection 19 G probe (abee tip 0.3 × 1 mm, Oertli Switzerland). The bipolar current with a frequency of 500 kHz is applied. The nasal sclera was penetrated repetitively six times through the trabecular meshwork and consecutively through Schlemm’s canal. Every time, a pocket of 0.3 mm high and 0.6 mm width was created. Results: Mean preoperative intraocular pressure (IOP) was 24.5 ± 2.1 mmHg (range 21 to 48 mmHg). After 48 months, the follow up average IOP was 15.0 ± 1.7 mmHg (range 10 to 20 mmHg). Postoperative IOP has been significantly reduced compared to preoperative IOP for all studied cases (p < 0.001). After 48 months, the target IOP less than 21 mmHg reached in 84.9%. No serious complications were observed during the surgical procedure itself and in the postoperative period. Conclusions: HFDS is a minimally invasive procedure. It is a safe and efficacious surgical technique for lowering IOP combined with cataract surgery.

Verified
Journal Article
Open access
PDF file
Bojan PajicBojan Pajic
Bojan Pajic
HMHorace Massa
Horace Massa
PBPhilipp B. Baenninger
Philipp B. Baenninger
Erika EskinaErika Eskina
Erika Eskina
BPBrigitte Pajic-Eggspuehler
Brigitte Pajic-Eggspuehler
Zeljka CvejicZeljka Cvejic
Zeljka Cvejic
Background: Presbyopia treatment in pseudophakic patients with a monofocal IOL is challenging. This study investigates the refractive results of femto-PresbyLASIK and analyzes presbyopia treatment in pseudophakic eyes. Methods: 14 patients with 28 pseudophakic eyes were treated with femto-PresbyLASIK. The dominant eye was targeted at a distance and the non-dominant eye at −0.5 D. The presbyopic algorithm creates a steepness in the cornea center by using an excimer laser that leads to corneal multifocality. Results: 6 months after surgery a refraction of −0.11 ± 0.13 D (p = 0.001), an uncorrected distance visual acuity of 0.05 ± 1.0 logMAR (p < 0.001) and an uncorrected near visual acuity of 0.15 ± 0.89 logMAR (p = 0.001) were achieved in the dominant eye. For the non-dominant eye, the refraction was −0.28 ± 0.22 D (p = 0.002), the uncorrected distance of visual acuity was 0.1 ± 1.49 logMAR, and the uncorrected near visual acuity was 0.11 ± 0.80 logMAR (p < 0.001). Spherical aberrations (Z400) were reduced by 0.21–0.3 µm in 32% of eyes, and by 0.31–0.4 µm in 26% of eyes. Conclusion: By steepening the central cornea while maintaining spherical aberrations within acceptable limits, PresbyLASIK created a corneal multifocality that safely improved near vision in both eyes. Thus, femto-PresbyLASIK can be used to treat presbyopia in pseudophakic eyes without performing intraocular surgery.

14 October 2023 in Medicina
Verified
Journal Article
Open access
PDF file
DRDragana Ristic
Dragana Ristic
MRMirko Resan
Mirko Resan
IPIgor Panchevski
Igor Panchevski
PRPetar Ristic
Petar Ristic
MVMiroslav Vukosavljevic
Miroslav Vukosavljevic
Bojan PajicBojan Pajic
Bojan Pajic
Background and Objectives: Early diagnosis of the exudative form of age-related macular degeneration (AMD) is very important for a timely first treatment, which is directly related to the preservation of functional visual acuity over a long period. The goal of this paper was to examine the correlation between the double-layer sign (DLS) and the presence of non-exudative macular neovascularization (MNV). Materials and Methods: Our research included 60 patients with AMD, exudative in one eye and non-exudative in the other eye. We analyzed only the non-exudative form using optical coherence tomography (OCT) and optical coherence tomography angiography (OCT-A). The patients were classified into three groups, depending on the duration of the disease (5 years). The onset of the disease was deemed the moment of establishing a diagnosis of exudative AMD in one eye. We defined the presence or absence of a DLS using OCT and the presence of non-exudative MNV using OCT-A, both on 3 × 3 mm and 6 × 6 mm sections. DLS was used as a projection biomarker for non-exudative MNV, with the aim of establishing a rapid diagnosis and achieving early treatment of the disease. Results: We found that there was a statistically significant correlation between the DLS diagnosed using OCT and non-exudative MNV diagnosed by OCT-A for both 3 × 3 mm (p < 0.001) and 6 × 6 mm (p < 0.001) imaging. There was a statistically significant difference between the frequencies of both DLS and MNV in Groups I and III on both 3 × 3 and 6 × 6 mm imaging. A statistically significant difference was also noted in the frequencies of DLS and MNV on 6 × 6 mm imaging, but not on 3 × 3 mm imaging, between Groups I and II. No differences were found between the frequencies of DLS and MNV between Groups II and III. Conclusions: The DLS on OCT can be used as a projection biomarker to assess the presence of a non-exudative MNV.