Amaia Zurutuza

Dr. Amaia Zurutuza

Graphenea
+1
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 August 2021 in Journal of the American Chemical Society
Verified
Journal Article
Open access
JVJuan-Jesús Velasco-Vélez
Juan-Jesús Velasco-Vélez
ECEmilia A. Carbonio
Emilia A. Carbonio
CCCheng-Hao Chuang
Cheng-Hao Chuang
CHCheng-Jhih Hsu
Cheng-Jhih Hsu
JLJyh-Fu Lee
Jyh-Fu Lee
TJTravis E. Jones
Travis E. Jones
Iridium and ruthenium and their oxides/hydroxides are the best candidates for the oxygen evolution reaction under harsh acidic conditions owing to the low overpotentials observed for Ru- and Ir-based anodes and the high corrosion resistance of Ir-oxides. Herein, by means of cutting edge operando surface and bulk sensitive X-ray spectroscopy techniques, specifically designed electrode nanofabrication and ab initio DFT calculations, we were able to reveal the electronic structure of the active IrOx centers (i.e., oxidation state) during electrocatalytic oxidation of water in the surface and bulk of high-performance Ir-based catalysts. We found the oxygen evolution reaction is controlled by the formation of empty Ir 5d states in the surface ascribed to the formation of formally IrV species leading to the appearance of electron-deficient oxygen species bound to single iridium atoms (μ1-O and μ1-OH) that are responsible for water activation and oxidation. Oxygen bound to three iridium centers (μ3-O) remains the dominant species in the bulk but do not participate directly in the electrocatalytic reaction, suggesting bulk oxidation is limited. In addition a high coverage of a μ1-OO (peroxo) species during the OER is excluded. Moreover, we provide the first photoelectron spectroscopic evidence in bulk electrolyte that the higher surface-to-bulk ratio in thinner electrodes enhances the material usage involving the precipitation of a significant part of the electrode surface and near-surface active species.

3 February 2014 in Nano Letters
Verified
Journal Article
Closed access
WWWei Li Wang
Wei Li Wang
Elton SantosElton Santos
Elton Santos
BJBin Jiang
Bin Jiang
ECEkin Dogus Cubuk
Ekin Dogus Cubuk
COColin Ophus
Colin Ophus
EKEfthimios Kaxiras
Efthimios Kaxiras

6 November 2017 in Nanoscale
Verified
Journal Article
Open access
PDF file
CBChristian Berger
Christian Berger
RPRory Phillips
Rory Phillips
ACAlba Centeno
Alba Centeno
AZAmaia Zurutuza
Amaia Zurutuza
AVAravind Vijayaraghavan
Aravind Vijayaraghavan
We describe the fabrication and characterisation of a capacitive pressure sensor formed by an ultra-thin graphene–polymer heterostructure membrane spanning a large array of micro-cavities each up to 30 μm in diameter with 100% yield. Sensors covering an area of just 1 mm2 show reproducible pressure transduction under static and dynamic loading up to pressures of 250 kPa. The measured capacitance change in response to pressure is in good agreement with calculations. Further, we demonstrate high-sensitivity pressure sensors by applying a novel strained membrane transfer and optimising the sensor architecture. This method enables suspended structures with less than 50 nm of air dielectric gap, giving a pressure sensitivity of 123 aF Pa−1 mm−2 over a pressure range of 0 to 100 kPa.

20 February 2018 in 2D Materials
Verified
Journal Article
Open access
PDF file
LALuca Anzi
Luca Anzi
AMAida Mansouri
Aida Mansouri
PPPaolo Pedrinazzi
Paolo Pedrinazzi
EGErica Guerriero
Erica Guerriero
MFMarco Fiocco
Marco Fiocco
RSRoman Sordan
Roman Sordan

27 November 2019 in Nanoscale
Verified
Journal Article
Open access
PDF file
LFLaura Fusco
Laura Fusco
MGMarina Garrido
Marina Garrido
Cristina MartínCristina Martín
Cristina Martín
SSSilvio Sosa
Silvio Sosa
CPCristina Ponti
Cristina Ponti
MPMarco Pelin
Marco Pelin
Graphene related materials, if prepared with non-irritant exfoliation agents, do not induce skin irritation on a 3D model of human epidermis, following the OECD guideline 439.

24 August 2023 in ACS Applied Electronic Materials
Verified
Journal Article
Open access
MSMiika Soikkeli
Miika Soikkeli
AMAnton Murros
Anton Murros
ARArto Rantala
Arto Rantala
OTOihana Txoperena
Oihana Txoperena
OKOlli-Pekka Kilpi
Olli-Pekka Kilpi
MPMika Prunnila
Mika Prunnila
The reliability of analysis is becoming increasingly important as point-of-care diagnostics are transitioning from single-analyte detection toward multiplexed multianalyte detection. Multianalyte detection benefits greatly from complementary metal-oxide semiconductor (CMOS) integrated sensing solutions, offering miniaturized multiplexed sensing arrays with integrated readout electronics and extremely large sensor counts. The development of CMOS back end of line integration compatible graphene field-effect transistor (GFET)-based biosensing has been rapid during the past few years, in terms of both the fabrication scale-up and functionalization toward biorecognition from real sample matrices. The next steps in industrialization relate to improving reliability and require increased statistics. Regarding functionalization toward truly quantitative sensors, on-chip bioassays with improved statistics require sensor arrays with reduced variability in functionalization. Such multiplexed bioassays, whether based on graphene or on other sensitive nanomaterials, are among the most promising technologies for label-free electrical biosensing. As an important step toward that, we report wafer-scale fabrication of CMOS-integrated GFET arrays with high yield and uniformity, designed especially for biosensing applications. We demonstrate the operation of the sensing platform array with 512 GFETs in simultaneous detection for the sodium chloride concentration series. This platform offers a truly statistical approach on GFET-based biosensing and further to quantitative and multianalyte sensing. The reported techniques can also be applied to other fields relying on functionalized GFETs, such as gas or chemical sensing or infrared imaging.