Alba Centeno

Alba Centeno

Auto-generated profile, based on publicly available information

Alba Centeno

Graphenea SA San Sebastian Spain

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2017 in Nanoscale
Verified
Journal Article
Open access
PDF file
CBChristian Berger
Christian Berger
RPRory Phillips
Rory Phillips
ACAlba Centeno
Alba Centeno
AZAmaia Zurutuza
Amaia Zurutuza
AVAravind Vijayaraghavan
Aravind Vijayaraghavan
We describe the fabrication and characterisation of a capacitive pressure sensor formed by an ultra-thin graphene–polymer heterostructure membrane spanning a large array of micro-cavities each up to 30 μm in diameter with 100% yield. Sensors covering an area of just 1 mm2 show reproducible pressure transduction under static and dynamic loading up to pressures of 250 kPa. The measured capacitance change in response to pressure is in good agreement with calculations. Further, we demonstrate high-sensitivity pressure sensors by applying a novel strained membrane transfer and optimising the sensor architecture. This method enables suspended structures with less than 50 nm of air dielectric gap, giving a pressure sensitivity of 123 aF Pa−1 mm−2 over a pressure range of 0 to 100 kPa.

20 February 2018 in 2D Materials
Verified
Journal Article
Open access
PDF file
LALuca Anzi
Luca Anzi
AMAida Mansouri
Aida Mansouri
PPPaolo Pedrinazzi
Paolo Pedrinazzi
EGErica Guerriero
Erica Guerriero
MFMarco Fiocco
Marco Fiocco
RSRoman Sordan
Roman Sordan

27 November 2019 in Nanoscale
Verified
Journal Article
Open access
PDF file
LFLaura Fusco
Laura Fusco
MGMarina Garrido
Marina Garrido
Cristina MartínCristina Martín
Cristina Martín
SSSilvio Sosa
Silvio Sosa
CPCristina Ponti
Cristina Ponti
MPMarco Pelin
Marco Pelin
Graphene related materials, if prepared with non-irritant exfoliation agents, do not induce skin irritation on a 3D model of human epidermis, following the OECD guideline 439.

24 August 2023 in ACS Applied Electronic Materials
Verified
Journal Article
Open access
MSMiika Soikkeli
Miika Soikkeli
AMAnton Murros
Anton Murros
ARArto Rantala
Arto Rantala
OTOihana Txoperena
Oihana Txoperena
OKOlli-Pekka Kilpi
Olli-Pekka Kilpi
MPMika Prunnila
Mika Prunnila
The reliability of analysis is becoming increasingly important as point-of-care diagnostics are transitioning from single-analyte detection toward multiplexed multianalyte detection. Multianalyte detection benefits greatly from complementary metal-oxide semiconductor (CMOS) integrated sensing solutions, offering miniaturized multiplexed sensing arrays with integrated readout electronics and extremely large sensor counts. The development of CMOS back end of line integration compatible graphene field-effect transistor (GFET)-based biosensing has been rapid during the past few years, in terms of both the fabrication scale-up and functionalization toward biorecognition from real sample matrices. The next steps in industrialization relate to improving reliability and require increased statistics. Regarding functionalization toward truly quantitative sensors, on-chip bioassays with improved statistics require sensor arrays with reduced variability in functionalization. Such multiplexed bioassays, whether based on graphene or on other sensitive nanomaterials, are among the most promising technologies for label-free electrical biosensing. As an important step toward that, we report wafer-scale fabrication of CMOS-integrated GFET arrays with high yield and uniformity, designed especially for biosensing applications. We demonstrate the operation of the sensing platform array with 512 GFETs in simultaneous detection for the sodium chloride concentration series. This platform offers a truly statistical approach on GFET-based biosensing and further to quantitative and multianalyte sensing. The reported techniques can also be applied to other fields relying on functionalized GFETs, such as gas or chemical sensing or infrared imaging.

25 May 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
EGErica Guerriero
Erica Guerriero
PPPaolo Pedrinazzi
Paolo Pedrinazzi
AMAida Mansouri
Aida Mansouri
OHOmid Habibpour
Omid Habibpour
MWMichael Winters
Michael Winters
RSRoman Sordan
Roman Sordan
The high-frequency performance of transistors is usually assessed by speed and gain figures of merit, such as the maximum oscillation frequency fmax, cutoff frequency fT, ratio fmax/fT, forward transmission coefficient S21, and open-circuit voltage gain Av. All these figures of merit must be as large as possible for transistors to be useful in practical electronics applications. Here we demonstrate high-performance graphene field-effect transistors (GFETs) with a thin AlOx gate dielectric which outperform previous state-of-the-art GFETs: we obtained fmax/fT > 3, Av > 30 dB, and S21 = 12.5 dB (at 10 MHz and depending on the transistor geometry) from S-parameter measurements. A dc characterization of GFETs in ambient conditions reveals good current saturation and relatively large transconductance ~600 S/m. The realized GFETs offer the prospect of using graphene in a much wider range of electronic applications which require substantial gain.

6 February 2025 in Nature Communications
Verified
Journal Article
Open access
PDF file
BCBárbara Canto
Bárbara Canto
MOMartin Otto
Martin Otto
AMArantxa Maestre
Arantxa Maestre
ACAlba Centeno
Alba Centeno
AZAmaia Zurutuza
Amaia Zurutuza
MLMax Lemme
Max Lemme
The commercialization of electronic devices based on graphene has not yet been successful, even 20 years after its first isolation. To this end, the European Commission is supporting research toward establishing a European experimental pilot line for electronic and optoelectronic devices based on graphene and related two-dimensional (2D) materials, namely the Experimental Pilot Line (2D-EPL) project. Here, we report the results obtained during the first and third multi-project wafer (MPW) runs completed at the end of 2022 (MPW run 1) and 2023 (MPW run 3) as an outcome of the 2D-EPL. Test devices were measured across the wafers to assess the device quality and variability before delivering the fabricated dies to the customers. Raman spectroscopy confirmed minimal structural changes in the graphene caused by the fabrication process, while electrical measurements of two different device types verified the device specifications defined in the process design kit.