Giacomo Fanti

Mr. Giacomo Fanti

Insubria University, Department of Science and High Technology, Italy
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Giacomo FantiGiacomo Fanti
Giacomo Fanti
Francesca BorghiFrancesca Borghi
Francesca Borghi
Andrea SpinazzèAndrea Spinazzè
Andrea Spinazzè
SRSabrina Rovelli
Sabrina Rovelli
DCDavide Campagnolo
Davide Campagnolo
Domenico Maria CavalloDomenico Maria Cavallo
Domenico Maria Cavallo
In the last years, the issue of exposure assessment of airborne pollutants has been on the rise, both in the environmental and occupational fields. Increasingly severe national and international air quality standards, indoor air guidance values, and exposure limit values have been developed to protect the health of the general population and workers; this issue required a significant and continuous improvement in monitoring technologies to allow the execution of proper exposure assessment studies. One of the most interesting aspects in this field is the development of the “next-generation” of airborne pollutants monitors and sensors (NGMS). The principal aim of this review is to analyze and characterize the state of the art and of NGMS and their practical applications in exposure assessment studies. A systematic review of the literature was performed analyzing outcomes from three different databases (Scopus, PubMed, Isi Web of Knowledge); a total of 67 scientific papers were analyzed. The reviewing process was conducting systematically with the aim to extrapolate information about the specifications, technologies, and applicability of NGMSs in both environmental and occupational exposure assessment. The principal results of this review show that the use of NGMSs is becoming increasingly common in the scientific community for both environmental and occupational exposure assessment. The available studies outlined that NGMSs cannot be used as reference instrumentation in air monitoring for regulatory purposes, but at the same time, they can be easily adapted to more specific applications, improving exposure assessment studies in terms of spatiotemporal resolution, wearability, and adaptability to different types of projects and applications. Nevertheless, improvements needed to further enhance NGMSs performances and allow their wider use in the field of exposure assessment are also discussed.

12 June 2021 in Toxics
Verified
Journal Article
Open access
PDF file
Francesca BorghiFrancesca Borghi
Francesca Borghi
Andrea SpinazzèAndrea Spinazzè
Andrea Spinazzè
SMSimone Mandaglio
Simone Mandaglio
Giacomo FantiGiacomo Fanti
Giacomo Fanti
DCDavide Campagnolo
Davide Campagnolo
Domenico Maria CavalloDomenico Maria Cavallo
Domenico Maria Cavallo
Recently, the need to assess personal exposure in different micro-environments has been highlighted. Further, estimating the inhaled dose of pollutants is considerably one of the most interesting parameters to be explored to complete the fundamental information obtained through exposure assessment, especially if associated with a dose-response approach. To analyze the main results obtained from the studies related to the estimation of the inhaled dose of pollutants in different micro-environments (environments in which an individual spends a part of his day), and to identify the influence of different parameters on it, a systematic review of the literature was performed. The principal outcomes from the considered studies outlined that (i) exposure concentration and residence time are among the most important parameters to be evaluated in the estimation of the inhaled dose, especially in transport environments. Further, (ii) the pulmonary ventilation rate can be of particular interest during active commuting because of its increase, which increases the inhalation of pollutants. From a methodological point of view, the advent of increasingly miniaturized, portable and low-cost technologies could favor these kinds of studies, both for the measurement of atmospheric pollutants and the real-time evaluation of physiological parameters used for estimation of the inhaled dose. The main results of this review also show some knowledge gaps. In particular, numerous studies have been conducted for the evaluation (in terms of personal exposure and estimation of the inhaled dose) of different PM fractions: other airborne pollutants, although harmful to human health, are less represented in studies of this type: for this reason, future studies should be conducted, also considering other air pollutants, not neglecting the assessment of exposure to PM. Moreover, many studies have been conducted indoors, where the population spends most of their daily time. However, it has been highlighted how particular environments, even if characterized by a shorter residence time, can contribute significantly to the dose of inhaled pollutants. These environments are, therefore, of particular importance and should be better evaluated in future studies, as well as occupational environments, where the work results in a high pulmonary ventilation rate. The attention of future studies should also be focused on these categories of subjects and occupational studies.

1 October 2021 in Atmospheric Environment
Verified
Journal Article
Closed access
LBLuca Boniardi
Luca Boniardi
Francesca BorghiFrancesca Borghi
Francesca Borghi
SSSerena Straccini
Serena Straccini
Giacomo FantiGiacomo Fanti
Giacomo Fanti
DCDavide Campagnolo
Davide Campagnolo
SFSilvia Fustinoni
Silvia Fustinoni

Andrea SpinazzèAndrea Spinazzè
Andrea Spinazzè
Francesca BorghiFrancesca Borghi
Francesca Borghi
DCDavide Campagnolo
Davide Campagnolo
SRSabrina Rovelli
Sabrina Rovelli
MKMarta Keller
Marta Keller
Domenico Maria CavalloDomenico Maria Cavallo
Domenico Maria Cavallo
Evaluation and validation studies of quantitative exposure models for occupational exposure assessment are still scarce and generally only consider a limited number of exposure scenarios. The aim of this review was to report the current state of knowledge of models’ reliability in terms of precision, accuracy, and robustness. A systematic review was performed through searches of major scientific databases (Web of Science, Scopus, and PubMed), concerning reliability of Tier1 (“ECETOC TRA”-European Centre for Ecotoxicology and Toxicology of Chemicals Targeted Risk Assessment, MEASE, and EMKG-Expo-Tool) and Tier2 models (STOFFENMANAGER® and “ART”-Advanced Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) Tool). Forty-five studies were identified, and we report the complete information concerning model performance in different exposure scenarios, as well as between-user reliability. Different studies describe the ECETOC TRA model as insufficient conservative to be a Tier1 model, in different exposure scenarios. Contrariwise, MEASE and EMKG-Expo-Tool seem to be conservative enough, even if these models have not been deeply evaluated. STOFFENMANAGER® resulted the most balanced and robust model. Finally, ART was generally found to be the most accurate and precise model, with a medium level of conservatism. Overall, the results showed that no complete evaluation of the models has been conducted, suggesting the need for correct and harmonized validation of these tools.

Francesca BorghiFrancesca Borghi
Francesca Borghi
Andrea SpinazzèAndrea Spinazzè
Andrea Spinazzè
Giacomo FantiGiacomo Fanti
Giacomo Fanti
DCDavide Campagnolo
Davide Campagnolo
SRSabrina Rovelli
Sabrina Rovelli
Domenico Maria CavalloDomenico Maria Cavallo
Domenico Maria Cavallo
Several studies evaluating exposure to pollutants in microenvironments (MEs) are available in the scientific literature, but studies that evaluate the inhaled doses of pollutants are few in number. Therefore, this study aimed to evaluate the exposure of commuters to different pollutants (i.e., nitrogen dioxide [NO2] and fractionated particulate matter [PM], including ultrafine particles [UFPs]) using miniaturized and portable real-time monitoring instruments in selected MEs; the inhaled doses of these pollutants were estimated for each of these MEs. Measurements were performed along a typical commute, considering different traffic and nontraffic MEs. Experimental data were collected over four working weeks in two different seasons (winter and summer). Different portable and miniaturized instruments were used to evaluate PM and NO2 exposure. Furthermore, physiological parameters were evaluated using a heart rate monitor. The principal results show that higher exposure levels were measured in Underground (for all PM fractions and NO2) and in Car (UFP), while lower levels were measured in Car (PM and NO2) and in Train (UFP). In contrast, higher values of the inhaled cumulative dose were estimated in environments defined as Other, followed by Walking (ht), while lower values were observed in Walking (lt) and in Car.

27 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Giacomo FantiGiacomo Fanti
Giacomo Fanti
Andrea SpinazzèAndrea Spinazzè
Andrea Spinazzè
Francesca BorghiFrancesca Borghi
Francesca Borghi
SRSabrina Rovelli
Sabrina Rovelli
DCDavide Campagnolo
Davide Campagnolo
Domenico Maria CavalloDomenico Maria Cavallo
Domenico Maria Cavallo
Over the last decade, technological advancements have been made available and applied in a wide range of applications in several work fields, ranging from personal to industrial enforcements. One of the emerging issues concerns occupational safety and health in the Fourth Industrial Revolution and, in more detail, it deals with how industrial hygienists could improve the risk-assessment process. A possible way to achieve these aims is the adoption of new exposure-monitoring tools. In this study, a systematic review of the up-to-date scientific literature has been performed to identify and discuss the most-used sensors that could be useful for occupational risk assessment, with the intent of highlighting their pros and cons. A total of 40 papers have been included in this manuscript. The results show that sensors able to investigate airborne pollutants (i.e., gaseous pollutants and particulate matter), environmental conditions, physical agents, and workers’ postures could be usefully adopted in the risk-assessment process, since they could report significant data without significantly interfering with the job activities of the investigated subjects. To date, there are only few “next-generation” monitors and sensors (NGMSs) that could be effectively used on the workplace to preserve human health. Due to this fact, the development and the validation of new NGMSs will be crucial in the upcoming years, to adopt these technologies in occupational-risk assessment.