Sabrina Rovelli

Dr. Sabrina Rovelli

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Francesca BorghiFrancesca Borghi
Francesca Borghi
Andrea SpinazzèAndrea Spinazzè
Andrea Spinazzè
SRSabrina Rovelli
Sabrina Rovelli
DCDavide Campagnolo
Davide Campagnolo
LBLuca Del Buono
Luca Del Buono
Domenico Maria CavalloDomenico Maria Cavallo
Domenico Maria Cavallo
Air quality has a huge impact on different aspects of life quality, and for this reason, air quality monitoring is required by national and international regulations. Technical and procedural limitations of traditional fixed-site stations for monitoring or sampling of air pollutants are also well-known. Recently, a different type of miniaturized monitors has been developed. These monitors, due to their characteristics (e.g., low cost, small size, high portability) are becoming increasingly important for individual exposure assessment, especially since this kind of instrument can provide measurements at high spatial and temporal resolution, which is a notable advantage when approaching assessment of exposure to environmental contaminants. The aim of this study is indeed to provide information regarding current knowledge regarding the use of miniaturized air pollutant sensors. A systematic review was performed to identify original articles: a literature search was carried out using an appropriate query for the search of papers across three different databases, and the papers were selected using inclusion/exclusion criteria. The reviewed articles showed that miniaturized sensors are particularly versatile and could be applied in studies with different experimental designs, helping to provide a significant enhancement to exposure assessment, even though studies regarding their performance are still sparse.

SRSabrina Rovelli
Sabrina Rovelli
Andrea CattaneoAndrea Cattaneo
Andrea Cattaneo
CNCamilla P. Nuzzi
Camilla P. Nuzzi
Andrea SpinazzèAndrea Spinazzè
Andrea Spinazzè
SPSilvia Piazza
Silvia Piazza
Domenico Maria CavalloDomenico Maria Cavallo
Domenico Maria Cavallo
Indoor size-fractioned particulate matter (PM) was measured in seven schools in Milan, to characterize their concentration levels in classrooms, compare the measured concentrations with the recommended guideline values, and provide a preliminary assessment of the efficacy of the intervention measures, based on the guidelines developed by the Italian Ministry of Healthand applied to mitigate exposure to undesirable air pollutants. Indoor sampling was performed from Monday morning to Friday afternoon in three classrooms of each school and was repeated in winter 2011–2012 and 2012–2013. Simultaneously, PM2.5 samples were also collected outdoors. Two different photometers were used to collect the PM continuous data, which were corrected a posteriori using simultaneous gravimetric PM2.5 measurements. Furthermore, the concentrations of carbon dioxide (CO2) were monitored and used to determine the Air Exchange Rates in the classrooms. The results revealed poor IAQ in the school environment. In several cases, the PM2.5 and PM10 24 h concentrations exceeded the 24 h guideline values established by the World Health Organization (WHO). In addition, the indoor CO2 levels often surpassed the CO2 ASHRAE Standard. Our findings confirmed that important indoor sources (human movements, personal clouds, cleaning activities) emitted coarse particles, markedly increasing the measured PM during school hours. In general, the mean PM2.5 indoor concentrations were lower than the average outdoor PM2.5 levels, with I/O ratios generally <1. Fine PM was less affected by indoor sources, exerting a major impact on the PM1–2.5 fraction. Over half of the indoor fine particles were estimated to originate from outdoors. To a first approximation, the intervention proposed to reduce indoor particle levels did not seem to significantly influence the indoor fine PM concentrations. Conversely, the frequent opening of doors and windows appeared to significantly contribute to the reduction of the average indoor CO2 levels.

1 April 2018 in Environmental Pollution
Verified
Journal Article
Closed access
SSStefano Zauli Sajani
Stefano Zauli Sajani
SMStefano Marchesi
Stefano Marchesi
ATArianna Trentini
Arianna Trentini
DBDimitri Bacco
Dimitri Bacco
CZClaudia Zigola
Claudia Zigola
Roy HarrisonRoy Harrison
Roy Harrison

30 June 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Giacomo FantiGiacomo Fanti
Giacomo Fanti
Francesca BorghiFrancesca Borghi
Francesca Borghi
Andrea SpinazzèAndrea Spinazzè
Andrea Spinazzè
SRSabrina Rovelli
Sabrina Rovelli
DCDavide Campagnolo
Davide Campagnolo
Domenico Maria CavalloDomenico Maria Cavallo
Domenico Maria Cavallo
In the last years, the issue of exposure assessment of airborne pollutants has been on the rise, both in the environmental and occupational fields. Increasingly severe national and international air quality standards, indoor air guidance values, and exposure limit values have been developed to protect the health of the general population and workers; this issue required a significant and continuous improvement in monitoring technologies to allow the execution of proper exposure assessment studies. One of the most interesting aspects in this field is the development of the “next-generation” of airborne pollutants monitors and sensors (NGMS). The principal aim of this review is to analyze and characterize the state of the art and of NGMS and their practical applications in exposure assessment studies. A systematic review of the literature was performed analyzing outcomes from three different databases (Scopus, PubMed, Isi Web of Knowledge); a total of 67 scientific papers were analyzed. The reviewing process was conducting systematically with the aim to extrapolate information about the specifications, technologies, and applicability of NGMSs in both environmental and occupational exposure assessment. The principal results of this review show that the use of NGMSs is becoming increasingly common in the scientific community for both environmental and occupational exposure assessment. The available studies outlined that NGMSs cannot be used as reference instrumentation in air monitoring for regulatory purposes, but at the same time, they can be easily adapted to more specific applications, improving exposure assessment studies in terms of spatiotemporal resolution, wearability, and adaptability to different types of projects and applications. Nevertheless, improvements needed to further enhance NGMSs performances and allow their wider use in the field of exposure assessment are also discussed.

12 June 2021 in Toxics
Verified
Journal Article
Open access
PDF file
Francesca BorghiFrancesca Borghi
Francesca Borghi
Andrea SpinazzèAndrea Spinazzè
Andrea Spinazzè
SMSimone Mandaglio
Simone Mandaglio
Giacomo FantiGiacomo Fanti
Giacomo Fanti
DCDavide Campagnolo
Davide Campagnolo
Domenico Maria CavalloDomenico Maria Cavallo
Domenico Maria Cavallo
Recently, the need to assess personal exposure in different micro-environments has been highlighted. Further, estimating the inhaled dose of pollutants is considerably one of the most interesting parameters to be explored to complete the fundamental information obtained through exposure assessment, especially if associated with a dose-response approach. To analyze the main results obtained from the studies related to the estimation of the inhaled dose of pollutants in different micro-environments (environments in which an individual spends a part of his day), and to identify the influence of different parameters on it, a systematic review of the literature was performed. The principal outcomes from the considered studies outlined that (i) exposure concentration and residence time are among the most important parameters to be evaluated in the estimation of the inhaled dose, especially in transport environments. Further, (ii) the pulmonary ventilation rate can be of particular interest during active commuting because of its increase, which increases the inhalation of pollutants. From a methodological point of view, the advent of increasingly miniaturized, portable and low-cost technologies could favor these kinds of studies, both for the measurement of atmospheric pollutants and the real-time evaluation of physiological parameters used for estimation of the inhaled dose. The main results of this review also show some knowledge gaps. In particular, numerous studies have been conducted for the evaluation (in terms of personal exposure and estimation of the inhaled dose) of different PM fractions: other airborne pollutants, although harmful to human health, are less represented in studies of this type: for this reason, future studies should be conducted, also considering other air pollutants, not neglecting the assessment of exposure to PM. Moreover, many studies have been conducted indoors, where the population spends most of their daily time. However, it has been highlighted how particular environments, even if characterized by a shorter residence time, can contribute significantly to the dose of inhaled pollutants. These environments are, therefore, of particular importance and should be better evaluated in future studies, as well as occupational environments, where the work results in a high pulmonary ventilation rate. The attention of future studies should also be focused on these categories of subjects and occupational studies.

13 September 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Francesca BorghiFrancesca Borghi
Francesca Borghi
Andrea SpinazzèAndrea Spinazzè
Andrea Spinazzè
DCDavide Campagnolo
Davide Campagnolo
SRSabrina Rovelli
Sabrina Rovelli
Andrea CattaneoAndrea Cattaneo
Andrea Cattaneo
Domenico Maria CavalloDomenico Maria Cavallo
Domenico Maria Cavallo
The aim of this study was to evaluate the precision, accuracy, practicality, and potential uses of a PM2.5 miniaturized monitor (MM) in exposure assessment. These monitors (AirBeam, HabitatMap) were compared with the widely used direct-reading particulate matter monitors and a gravimetric reference method for PM2.5. Instruments were tested during 20 monitoring sessions that were subdivided in two different seasons to evaluate the performance of sensors across various environmental and meteorological conditions. Measurements were performed at an urban background site in Como, Italy. To evaluate the performance of the instruments, different analyses were conducted on 8-h averaged PM2.5 concentrations for comparison between direct-reading monitors and the gravimetric method, and minute-averaged data for comparison between the direct-reading instruments. A linear regression analysis was performed to evaluate whether the two measurement methods, when compared, could be considered comparable and/or mutually predictive. Further, Bland-Altman plots were used to determine whether the methods were characterized by specific biases. Finally, the correlations between the error associated with the direct-reading instruments and the meteorological parameters acquired at the sampling point were investigated. Principal results show a moderate degree of agreement between MMs and the reference method and a bias that increased with an increase in PM2.5 concentrations.