DC bias is a great threat to the safe operation of power transformers. This paper deals with a new vibration-based technique to diagnose DC bias in power transformers. With this technique, the DC bias status of power transformers can be automatically recognized. The vibration variation process of a 500 kV autotransformer is tested under the influence of DC bias in the monopole trail operation stage of a ±800 kV HVDC transmission system. Comparison of transformer vibration under normal and DC-biased conditions is conducted. Three features are proposed and are validated by sensitivity analysis. The principal component analysis method is employed for feature de-correlation and dimensionality reduction. The least square support vector machine algorithm is used and verified successful in DC bias recognition. A remote on-line monitoring device based on the proposed algorithm is designed and applied in field DC bias diagnosis of power transformers. The suggested diagnostic algorithm and monitoring device could be useful in targeted DC bias control and improving the safe operation level of power transformers.
1 October 2019 in IOP Conference Series: Materials Science and Engineering
Noise pollution, air pollution, water pollution and solid waste pollution are recognized as four major environmental pollution sources in the world. Based on the principle of noise reduction, noise reduction materials mainly include sound absorbing material, sound insulation material and noise damping material. In this paper, the mechanism, research progress and development trends of the three kinds noise reduction materials are reviewed and discussed.
1 August 2019 in IOP Conference Series: Earth and Environmental Science
Transformer is the core equipment in power plant and substation. Its safety problem directly affects the normal operation of the whole power plant or substation. In the event of fire, it not only affects the normal operation and system load of the system, but also affects the normal operation and load of the system. In this paper, the main causes of transformer fire, fire pre-warning technology and fire extinguishing technology are introduced comprehensively. A on-line detection fire warning technology without blackout is proposed by analyzing transformer operating noise. Finally, the substation fire protection technology from the aspect of civil engineering design is introduced briefly.
1 February 2020 in IOP Conference Series: Earth and Environmental Science
In this paper, based on the acoustic impedance tube model established by COMSOL, we studied the influence of the boundary conditions on the frequency characteristics of the damping acoustic plate, the effect of the thickness of the damping layer on the single-layer and double-layer sandwich structure damping acoustic plate. Based on the simulation results, two conclusions can be obtained: (1) the damping layer can effectively increase the sound insulation of the sound insulation plate, and when the thickness of the damping layer is 2∼3 times of the bottom plate thickness, the performance-price ratio is the highest; (2) the sound insulation characteristics of the damping sound insulation plate follow the law of mass, and the sound insulation increases with the increase of frequency under the free boundary condition, while under the fixed support boundary condition, the low frequency sound insulation is larger.
9 July 2019 in IOP Conference Series: Earth and Environmental Science
Irradiation processing has be widely used in industrial production, such as curing, cross-linking of polymers and preservation of food. A Ridgetron for material irradiation processing is studied in this paper, with output energy of 2.5 MeV. Overall description on the Ridgetron acceleration prototype, bending magnet design and optics calculation are introduced in the paper. The beam dynamics simulation and the particle trajectory calculation respectively ensure the beam focusing and parallel beams.
1 December 2019 in IOP Conference Series: Materials Science and Engineering
This paper investigates the internal and external noise characteristics of a 10kV oil-immersed transformer based on advanced acoustic measuring technology. A kind of fibre-optic hydrophone is installed inside the transformer and four acoustic sensors are placed outside in the air. The noise is measured under the condition of no-load and short circle, and the amplitude and frequency characteristics are obtained. The results show that the amplitude of internal noise is higher and contains more high order harmonics when compared with the external noise. It means the internal noise has a higher signal noise ratio, and contains more information. These results can be used for further research such as transformer noise generating mechanism, transmission regulation, transformer noise controlling.