1 October 2019 in IOP Conference Series: Materials Science and Engineering
Noise pollution, air pollution, water pollution and solid waste pollution are recognized as four major environmental pollution sources in the world. Based on the principle of noise reduction, noise reduction materials mainly include sound absorbing material, sound insulation material and noise damping material. In this paper, the mechanism, research progress and development trends of the three kinds noise reduction materials are reviewed and discussed.
1 August 2019 in IOP Conference Series: Earth and Environmental Science
Transformer is the core equipment in power plant and substation. Its safety problem directly affects the normal operation of the whole power plant or substation. In the event of fire, it not only affects the normal operation and system load of the system, but also affects the normal operation and load of the system. In this paper, the main causes of transformer fire, fire pre-warning technology and fire extinguishing technology are introduced comprehensively. A on-line detection fire warning technology without blackout is proposed by analyzing transformer operating noise. Finally, the substation fire protection technology from the aspect of civil engineering design is introduced briefly.
1 February 2020 in IOP Conference Series: Earth and Environmental Science
In this paper, based on the acoustic impedance tube model established by COMSOL, we studied the influence of the boundary conditions on the frequency characteristics of the damping acoustic plate, the effect of the thickness of the damping layer on the single-layer and double-layer sandwich structure damping acoustic plate. Based on the simulation results, two conclusions can be obtained: (1) the damping layer can effectively increase the sound insulation of the sound insulation plate, and when the thickness of the damping layer is 2∼3 times of the bottom plate thickness, the performance-price ratio is the highest; (2) the sound insulation characteristics of the damping sound insulation plate follow the law of mass, and the sound insulation increases with the increase of frequency under the free boundary condition, while under the fixed support boundary condition, the low frequency sound insulation is larger.
1 February 2020 in IOP Conference Series: Earth and Environmental Science
The noise of substation is generally generated by the main transformer, reactor, capacitor and other electrical equipment, in which the transformer is the main sound source equipment. Its spectrum characteristics are mainly low frequency noise, medium and high frequency noise as auxiliary. The noise band is wide, the wave grow is long, the attenuation is slow, and the penetration ability to the building structure is strong, which seriously affects the daily life of the residents. In this paper, the noise source of a 500kV substation with noise exceeding the standard is tested and analyzed first, then the noise reduction scheme design and sound field simulation calculation are carried out to verify the feasibility of the scheme.