Seung-Kyun Kang

Dr. Seung-Kyun Kang

Department of Materials Science and Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826, Korea
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2020 in Science Advances
Verified
Journal Article
Open access
PDF file
JKJahyun Koo
Jahyun Koo
SKSung Bong Kim
Sung Bong Kim
YCYeon Sik Choi
Yeon Sik Choi
Zhaoqian XieZhaoqian Xie
Zhaoqian Xie
Amay BandodkarAmay Bandodkar
Amay Bandodkar
JRJohn A. Rogers
John A. Rogers
Bioresorbable drug release platforms offer advanced treatment for hormone imbalances, malignant cancers, and diabetic conditions.

1 July 2021 in Materials Science and Engineering: R: Reports
Verified
Journal Article
Open access
JSJun-Seok Shim
Jun-Seok Shim
JRJohn A. Rogers
John A. Rogers
Seung-Kyun KangSeung-Kyun Kang
Seung-Kyun Kang

9 June 2020 in Advanced Functional Materials
Verified
Journal Article
Closed access
PDF file
YCYeon Sik Choi
Yeon Sik Choi
JKJahyun Koo
Jahyun Koo
YLYoung Joong Lee
Young Joong Lee
GLGeumbee Lee
Geumbee Lee
RARaudel Avila
Raudel Avila
John A. RogersJohn A. Rogers
John A. Rogers

5 August 2024 in Nature Electronics
Verified
Journal Article
Closed access
PDF file
JBJae-Young Bae
Jae-Young Bae
GHGyeong-Seok Hwang
Gyeong-Seok Hwang
YKYoung-Seo Kim
Young-Seo Kim
JJJooik Jeon
Jooik Jeon
MCMinseong Chae
Minseong Chae
Seung-Kyun KangSeung-Kyun Kang
Seung-Kyun Kang

20 December 2024 in Science Advances
Verified
Journal Article
Open access
JLJae-Hwan Lee
Jae-Hwan Lee
YKYoon-Nam Kim
Yoon-Nam Kim
JLJunsang Lee
Junsang Lee
JJJooik Jeon
Jooik Jeon
JBJae-Young Bae
Jae-Young Bae
Seung-Kyun KangSeung-Kyun Kang
Seung-Kyun Kang
Real-time monitoring of infinitesimal deformations on complex morphologies is essential for precision biomechanical engineering. While flexible strain sensors facilitate real-time monitoring with shape-adaptive properties, their sensitivity is generally lower than spectroscopic imaging methods. Crack-based strain sensors achieve enhanced sensitivity with gauge factors (GFs) exceeding 30,000; however, such GFs are only attainable at large strains exceeding several percent and decline below 10 for strains under 10 −3 , rendering them inadequate for minute deformations. Here, we introduce hypersensitive and flexible “meta-crack” sensors detecting infinitesimal strains through previously undiscovered crack-opening mechanisms. These sensors achieve remarkable GFs surpassing 1000 at strains of 10 −4 on substrates with a Poisson’s ratio of −0.9. The crack orientation–independent gap-widening behavior elucidates the origin of hypersensitivity, corroborated by simplified models and finite element analysis. Additionally, parallel mechanical circuits of meta-cracks effectively address the trade-off between resolution and maximum sensing threshold. In vivo real-time monitoring of cerebrovascular dynamics with a strain resolution of 10 −5 underscores the hypersensitivity and conformal adaptability of sensors.

10 February 2020 in MRS Bulletin
Verified
Journal Article
Open access
PDF file
Seung-Kyun KangSeung-Kyun Kang
Seung-Kyun Kang
LYLan Yin
Lan Yin
CBChristopher Bettinger
Christopher Bettinger
Precise control of the life cycle of materials has become critical. Long-lasting materials are not always the best—for example, nondegradable plastic waste is now a serious environmental problem. Transient electronic devices have a prescribed life cycle in which all or part of the device can physically dissolve, disappear, or degrade after their utility ends. This concept creates compelling opportunities for biodegradable temporary, implantable electronics that do not require removal; environmentally benign biodegradable electronics with zero waste; and security hardware with on-time system destruction. Nanoscale materials provide new uses for transient materials dissolution by scaling up the rate of degradation; for example, a microscale Si single crystal is not dissoluble, but at around 100 nm, the Si single crystal dissolves in approximately one month. Significant advances have been made in exploring transient, water-soluble, and biodegradable nano-/micromaterials, and their degradation chemistry and kinetics. Advancing the state of the art in transient electronics requires contributions from many disciplines of materials science ranging from materials analysis to applications. This article outlines the history of transient electronics and briefly overviews concepts and issues from inorganic- and organic-based electronic materials, process technology, and energy devices to trigger transient electronics.