Grzegorz Owczarek

Dr. Grzegorz Owczarek


Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2016
Verified
Conference Paper
Closed access
Zbigniew StempienZbigniew Stempien
Zbigniew Stempien
MKMarek Kozicki
Marek Kozicki
RPRyszard Pawlak
Ryszard Pawlak
Ewa KorzeniewskaEwa Korzeniewska
Ewa Korzeniewska
GOGrzegorz Owczarek
Grzegorz Owczarek
DSDariusz Sajna
Dariusz Sajna
This work describes the fabrication of ammonia gas sensors on textile substrates by using the reactive inkjet printing for the deposition the polyaniline gas sensing layers. These layers were printed over vacuum deposited gold electrodes designed for the purposes of sensor conductivity analysis. The sensing properties such as sensing linearity, response and recovery times were studied in the range of ammonia gas concentrations from 15 to 100 ppm. The fabricated sensors showed a relevant increase in relative resistance from 0.30 to 14.4 times after exposing to ammonia gas at the concentrations of 15-100 ppm for 120 sec.

1 December 2007 in Quantitative InfraRed Thermography Journal
Verified
Journal Article
Closed access
RORobert Olbrycht
Robert Olbrycht
BWBogusław Więcek
Bogusław Więcek
GGGrzegorz Gralewicz
Grzegorz Gralewicz
TŚTomasz Świątczak
Tomasz Świątczak
GOGrzegorz Owczarek
Grzegorz Owczarek

21 June 2021 in Sensors
Verified
Journal Article
Open access
PDF file
PZPatryk Zradziński
Patryk Zradziński
JKJolanta Karpowicz
Jolanta Karpowicz
KGKrzysztof Gryz
Krzysztof Gryz
GOGrzegorz Owczarek
Grzegorz Owczarek
Victoria RamosVictoria Ramos
Victoria Ramos
The aim of this study was to model and evaluate the Specific Energy Absorption Rate (SAR) values in humans in proximity to fixed multi-antenna I-RFID readers of passive tags under various scenarios mimicking exposure when they are incorporated in Real-Time Location Systems (RTLS), or used to monitor Personal Protective Equipment (PPE). The sources of the electromagnetic field (EMF) in the modelled readers were rectangular microstrip antennas at a resonance frequency in free space of 866 MHz from the ultra-high frequency (UHF) RFID frequency range of 865–868 MHz. The obtained results of numerical modelling showed that the SAR values in the body 5 cm away from the UHF RFID readers need consideration with respect to exposure limits set by international guidelines to prevent adverse thermal effects of exposure to EMF: when the effective radiated power exceeds 5.5 W with respect to the general public/unrestricted environments exposure limits, and with respect to occupational/restricted environments exposure limits, when the effective radiated power exceeds 27.5 W.

1 January 2006 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
PJPiotr Jurowski
Piotr Jurowski
RGRoman Goś
Roman Goś
JKJarosław Kuśmierczyk
Jarosław Kuśmierczyk
GOGrzegorz Owczarek
Grzegorz Owczarek
GGGrzegorz Gralewicz
Grzegorz Gralewicz
PURPOSE: To measure the temperature parameters on the corneal surface during the delivery of standardized ultrasound energy assisted with ophthalmic viscosurgical devices (OVDs) or different temperatures of irrigating solutions in an experimental animal model. SETTING: Department of Ophthalmology and Visual Rehabilitation, Medical University of Lodz, and Central Institute for Labor Protection, National Research Institute, Warsaw, Poland. METHODS: Thirty rabbits (60 eyes) were randomly divided into 6 groups in which different OVD or balanced salt solutions (BSS) were used: group 1: Viscoat (sodium hyaluronate 3%–chondroitin sulfate); group 2: Provisc (sodium hyaluronate 1%); group 3: soft-shell technique; group 4: Celoftal (hydroxypropyl methylcellulose 2%); group 5: BSS 22°C; and group 6: BSS 4°C. After the nucleus and lens cortex were removed, the anterior chamber was filled with OVD or BSS and a phaco tip was introduced into the pupillary plane and switched on. The same phaco tip parameters were used in all groups. For thermographic measurements (ie, maximal temperature [MT], dynamic rise in temperature [DRT], and time when the maximal level of temperature [TMLT] was achieved), a thermocamera was used. RESULTS: Mean preoperative temperature on the rabbit corneal surface was 22.76°C ± 1.48°C (SD). Working with a phaco tip increased the temperature in each group. A significantly higher MT was observed in group 5 (27.85°C ± 0.52°C), followed by group 2 (27.75°C ± 0.54°C), group 3 (27.74°C ± 0.46°C), and group 4 (27.25°C ± 0.60°C), than in group 6 (26.81°C ± 0.34°C) and group 1 (26.52°C ± 0.48°C) (P<.05). Significantly higher values of DRT and shorter TMLT values were observed in group 5 (1.16°C/s ± 0.42°C/s, 4 seconds) and group 6 (0.91°C/s ± 0.13°C/s, 5 seconds) than in groups 2, 3, 1, and 4 (0.09°C/s ± 0.07°C/s, 30 seconds; 0.08°C/s ± 0.04°C/s, 40 seconds; 0.07°C/s ± 0.03°C/s, 45 seconds; 0.06°C/s ± 0.02°C/s, 50 seconds, respectively) (P<.0001). CONCLUSIONS: Currently used OVDs potentially offer different levels of protection against the increase in temperature that occurs during phacoemulsification. Therefore, the surgeon should consider this aspect when choosing an OVD, particularly in difficult cases (ie, hard nucleus, shallow anterior chamber, endothelial abnormalities).

30 June 2019 in Fibres & Textiles in Eastern Europe
Verified
Journal Article
Closed access
APAdam Pościk
Adam Pościk
JSJoanna Szkudlarek
Joanna Szkudlarek
GOGrzegorz Owczarek
Grzegorz Owczarek
The purpose of high visibility products is to reflect light at a low angle towards the source, such as vehicle headlights. The article presents measurements of the photometric properties of selected retroreflective materials made either of microlenses on a textile base or microprisms on a polymer base. The effects of the structure of the textile and polymer layers on the photometric properties of high visibility materials is analysed and the test methods applied are described.

2 January 2016 in International Journal of Occupational Safety and Ergonomics
Verified
Journal Article
Open access
GOGrzegorz Owczarek
Grzegorz Owczarek
GGGrzegorz Gralewicz
Grzegorz Gralewicz
NSNatalia Skuza
Natalia Skuza
PJPiotr Jurowski
Piotr Jurowski
In this research the factors used to evaluate the light transmission through two types of acrylic hydrophobic intraocular lenses, one that contained yellow chromophore that blocks blue light transmission and the other which did not contain that filter, were defined according to various light condition, e.g., daylight and at night. The potential influence of light transmission trough intraocular lenses with or without yellow chromophore on functional vision in everyday environmental conditions was analysed.