Marek Kozicki

Prof. Marek Kozicki

Lodz University of Technology, Lodz, Poland
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2004 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
EPE Pantelis
E Pantelis
AKA K Karlis
A K Karlis
MKMarek Kozicki
Marek Kozicki
PPP Papagiannis
P Papagiannis
LSL Sakelliou
L Sakelliou
JRJ M Rosiak
J M Rosiak
The water equivalence and stable relative energy response of polymer gel dosimeters are usually taken for granted in the relatively high x-ray energy range of external beam radiotherapy based on qualitative indices such as mass and electron density and effective atomic number. However, these favourable dosimetric characteristics are questionable in the energy range of interest to brachytherapy especially in the case of lower energy photon sources such as 103Pd and 125I that are currently utilized. In this work, six representative polymer gel formulations as well as the most commonly used experimental set-up of a LiF TLD detector-solid water phantom are discussed on the basis of mass attenuation and energy absorption coefficients calculated in the energy range of 10 keV-10 MeV with regard to their water equivalence as a phantom and detector material. The discussion is also supported by Monte Carlo simulation results. It is found that water equivalence of polymer gel dosimeters is sustained for photon energies down to about 60 keV and no corrections are needed for polymer gel dosimetry of 169Yb or 192Ir sources. For 125I and 103Pd sources, however, a correction that is source-distance dependent is required. Appropriate Monte Carlo results show that at the dosimetric reference distance of 1 cm from a source, these corrections are of the order of 3% for 125I and 2% for 103Pd. These have to be compared with corresponding corrections of up to 35% for 125I and 103Pd and up to 15% even for the 169Yb energies for the experimental set-up of the LiF TLD detector-solid water phantom.

14 May 2008 in Medical Physics
Verified
Journal Article
Closed access
EPEvaggelos Pantelis
Evaggelos Pantelis
CAChristos Antypas
Christos Antypas
LPL. Petrokokkinos
L. Petrokokkinos
PKP. Karaiskos
P. Karaiskos
PPP. Papagiannis
P. Papagiannis
ISI. Seimenis
I. Seimenis

1 April 2016 in Carbohydrate Polymers
Verified
Journal Article
Closed access
MKMarek Kozicki
Marek Kozicki
MKMarek Kołodziejczyk
Marek Kołodziejczyk
MSMałgorzata Szynkowska-Jozwik
Małgorzata Szynkowska-Jozwik
Aleksandra PawlaczykAleksandra Pawlaczyk
Aleksandra Pawlaczyk
ELEwa Leśniewska
Ewa Leśniewska
AKAleksandra Karolczak
Aleksandra Karolczak

1 August 2004 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Closed access
PSPanagiotis Sandilos
Panagiotis Sandilos
AAAngelos Angelopoulos
Angelos Angelopoulos
PBPanagiotis Baras
Panagiotis Baras
KDKonstantinos Dardoufas
Konstantinos Dardoufas
PKPantelis Karaiskos
Pantelis Karaiskos
LVLampros Vlahos
Lampros Vlahos

12 January 2017 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
MKMarek Kozicki
Marek Kozicki
MJMalwina Jaszczak
Malwina Jaszczak
PMPiotr Maras
Piotr Maras
MDMariusz Dudek
Mariusz Dudek
MCMarian Cłapa
Marian Cłapa
This work presents an improvement of the VIPAR nd (‘nd’ stands for ‘normoxic, double’, or VIP) polymer gel dosimeter. The gel composition was altered by increasing the concentration of the monomeric components, N -vinylpyrrolidone (NVP) and N , N ′-methylenebisacrylamide (MBA), in co-solvent solutions. The optimal composition (VIPAR CT , where ‘CT’ stands for computed tomography, or VIC) comprised: 17% NVP, 8% MBA, 12% t-BuOH, 7.5% gelatine, 0.007% ascorbic acid, 0.0008% CuSO 4 × 5H 2 O and 0.02% hydroquinone. The following characteristics of VIC were achieved: (i) linear dose range of 0.9 _ 30 Gy, (ii) saturation for radiation doses of over 50 Gy, (iii) threshold dose of about 0.5 Gy, (iv) dose sensitivity of 0.171 Gy −1 s −1 , which is roughly 2.2 times higher than that of VIP (for nuclear magnetic resonance measurements). It was also found that VIC is dose- rate-independent, and its dose response does not alter if the radiation source is changed from electrons to photons for external beam radiotherapy. The gel responded similarly to irradiation with small changes in radiation energy but was sensitive to larger energy changes. The VIC gel retained temporal stability from 20 h until at least 10 d after irradiation, whereas spatial stability was retained from 20 h until at least 6 d after irradiation. The scheme adopted for VIC manufacturing yields repeatable gels in terms of radiation dose response. The VIC was also shown to perform better than VIP using x-ray computed tomography as a readout method; the dose sensitivity of VIC (0.397 HU Gy −1 ) was 1.5 times higher than that of VIP. Also, the dose resolution of VIC was better than that of VIP in the whole dose range examined.

1 September 2018 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
MJMalwina Jaszczak
Malwina Jaszczak
RWRadoslaw Wach
Radoslaw Wach
PMPiotr Maras
Piotr Maras
MDMariusz Dudek
Mariusz Dudek
MKMarek Kozicki
Marek Kozicki
This work discusses the substitution of a gelatine physical gel matrix with a matrix made of poly(ethylene oxide)- block -poly(propylene oxide)- block -poly(ethylene oxide) (Pluronic F-127) in five 3D radiotherapy polymer gel dosimeters: MAGAT, PAGAT, NIPAM, VIPAR nd (VIP) and VIPAR CT (VIC). The current research outcomes showed that not each polymer gel dosimeter could be manufactured with Pluronic F-127. Two of the polymer gel dosimeters (PAGAT and VIP) containing the Pluronic F-127 matrix allowed for some proper dose response for radiotherapy dosimetry (a response to a dose range of e.g. 0‒50 Gy). The new best performing Pluronic-based polymer gel dosimeters were characterised by improved nuclear magnetic resonance properties, when being compared to gels with gelatine matrix at the same monomer content. These are: (i) a ~33% higher dose sensitivity; (ii) a comparable or slightly higher linear and dynamic dose range and (iii) a lower (new VIP composition, VIP3) or equivocal (new PAGAT composition, PAGAT2-Pluronic) dose threshold. However, there might be optimised gelatine based polymer dosimeters demonstrating even better sensitivity. UV–vis spectrophotometry measurements revealed that Pluronic matrices ensure six-times lower (VIP3–Pluronic) and eight-times lower (PAGAT2-Pluronic) absorbance (at 400 nm) of non-irradiated gels compared to gelatine matrices, which makes the new polymer gel dosimeters optically improved in comparison to their corresponding gelatine-based compositions. The differences in absorption reduce for higher wavelengths. Differential scanning calorimetry measurements revealed the following temperature stability ranges for the gels: (i) VIP with gelatine matrix: 0 °C‒26 °C, (ii) VIP3 with Pluronic matrix: 13.8 °C–55.2 °C, (iii) PAGAT2 with gelatine matrix: 0 °C–80 °C and (iv) PAGAT2 with Pluronic matrix: 21.4 °C–55.2 °C. In conclusion, Pluronic F-127 is an attractive co-polymer to serve as a substitute for the gelatine matrix in some 3D polymer gel dosimeters.