Elisabetta Bucaletti

Dr. Elisabetta Bucaletti

Università degli Studi di Firenze - Dipartimento di Medicina Sperimentale e Clinica
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2022 in Safety
Verified
Journal Article
Open access
PDF file
Stefano DugheriStefano Dugheri
Stefano Dugheri
GCGiovanni Cappelli
Giovanni Cappelli
LTLucia Trevisani
Lucia Trevisani
SKSimon Kemble
Simon Kemble
FPFabrizio Paone
Fabrizio Paone
Giulio ArcangeliGiulio Arcangeli
Giulio Arcangeli
Metal-additive manufacturing (AM), particularly the powder-bed fusion (PBF) technique, is undergoing a transition from the short-run production of components to higher-volume manufacturing. The industry’s increased production efficiency is paired with a growing awareness of the risks related to the inhalation of very fine metal powders during PBF and AM processes, and there is a pressing need for a ready-to-use approach to assess the risks and the occupational exposure to these very final metal powders. This article presents a study conducted in an AM facility, which was conducted with the aim to propose a solution to monitor incidental airborne particle emissions during metal AM by setting up an analytical network for a tailored approach to risk assessment. Quantitative data about the respirable and inhalable particle and metal content were obtained by gravimetric and ICP-MS analyses. In addition, the concentrations of airborne particles (10–300 nm) were investigated using a direct reading instrument. A qualitative approach for risk assessment was fulfilled using control banding Nanotool v2.0. The results show that the operations in the AM facility are in line with exposure limit levels for both micron-sized and nano-sized particles. The particulate observed in the working area contains metals, such as chromium, cobalt, and nickel; thus, biological monitoring is recommended. To manage the risk level observed for all of the tasks during the AM process, containment and the supervision of an occupational safety expert are recommended to manage the risk. This study represents a useful tool that can be used to carry out a static evaluation of the risk and exposure to potentially harmful very fine metal powders in AM; however, due to the continuous innovations in this field, a dynamic approach could represent an interesting future perspective for occupational safety.

25 October 2023 in Separations
Verified
Journal Article
Open access
PDF file
CBCarolina` Barola
Carolina` Barola
EBElisabetta Bucaletti
Elisabetta Bucaletti
Simone MorettiSimone Moretti
Simone Moretti
Francesca BuiarelliFrancesca Buiarelli
Francesca Buiarelli
Giulia SimonettiGiulia Simonetti
Giulia Simonetti
RGRoberta Galarini
Roberta Galarini
Poly- and perfluorinated alkyl substances (PFASs) are widely used in the electrical and electronic appliance industry to the point that waste of electrical and electronic equipment (WEEE), also known as e-waste, creates significant potential for PFAS exposure (by inhalation, ingestion, or dermal exposure) for people handling and recycling e-waste. The aim of this work was the development of an untargeted analytical approach in order to detect the presence of possible unknown PFASs in particulate matter collected in three Italian e-waste facilities through liquid chromatography coupled to high-resolution tandem mass spectrometry (LC-HR-MS/MS) in negative ionization mode. By means of three acquisition experiments, nine compounds were detected as candidate PFASs, and three were definitively confirmed by comparison with their authentic standards. Among these, bistriflimide (bis (trifluoromethylsulfonyl) imide), an ionic liquid with several promising technological applications, was the most abundant compound detected in all three recycling plants. This is the first study associating the presence of fluorinated ionic liquids with e-waste, and as these chemicals are not only toxic and persistent but also highly mobile, our results indicate the need to include them in future PFAS research. Only further data on their actual environmental diffusion will determine whether they are emerging pollutants or not.

13 May 2020 in European Journal of Organic Chemistry
Verified
Journal Article
Closed access
PDF file
ELElena Lenci
Elena Lenci
RPRaffaele Bellini Puglielli
Raffaele Bellini Puglielli
EBElisabetta Bucaletti
Elisabetta Bucaletti
RIRiccardo Innocenti
Riccardo Innocenti
Andrea TrabocchiAndrea Trabocchi
Andrea Trabocchi

28 December 2023 in Environmental Pollution
Verified
Journal Article
Open access
Simone MorettiSimone Moretti
Simone Moretti
Gianfranco BrambillaGianfranco Brambilla
Gianfranco Brambilla
FMFulvio Maffucci
Fulvio Maffucci
CBCarolina` Barola
Carolina` Barola
EBElisabetta Bucaletti
Elisabetta Bucaletti
MEMauro Esposito
Mauro Esposito
Per-and Poly-FluoroAlkyl Substances (PFAS) are a class of persistent, toxic, and mobile and chemicals both from industrial sources and from the use and disposal of Consumers products containing PFAS, whose concentration in marine food webs could pose a toxicological risk for biota and humans. In 2021, unhatched eggs were sampled from 41 loggerhead turtle Caretta caretta nests from the Italian shores of the Campania Region (Southern Italy). Whole eggs were analysed for the presence of 66 legacy and emerging PFAS with Liquid Chromatography coupled to Hybrid High Resolution Mass Spectrometry. A median Σ66 Per- and Poly-FluoroAlkyl Substances value of 3.34 ng/g egg fresh weight was found; perfluoroctane sulfonate (PFOS) represented the most contributing congener (47%), followed by perfluoro-n-undecanoic acid, perfluoro-n-tridecanoic acid, perfluoro-n-decanoic acid, perfluoro-n-decanoic acid, and perfluoro-n-tetradecanoic acid, respectively. Such compounds showed a log-norm distribution, suggesting found concentrations could represent the baseline levels in the considered sampling area. Emerging ChloroPolyFluoroPolyEthers Carboxylic Acids (ClPFECAs) were found in 20 out of 41 samples in the range 0.01-1.59 ng/g. Four samples had 20-100 fold higher concentration compared to that of other samples, suggesting the presence of hot spot areas possibly related to presence of fluoropolymer-based marine litter turtles may ingest. The analysis of two paired eggs/liver samples recovered from stranded animals revealed PFAS concentration in the same order of magnitude, supporting the role of vitellogenin in their selective transfer to yolk. Significant (P = 0.0155) Kendall negative correlation coefficient of -0.2705 among PFOS content in eggs and the recorded hatching success prompts for further investigation on associated exposure assessment and related eco-toxicity risk. This work reports for the first time PFAS presence in georeferenced loggerhead turtle eggs of the Mediterranean Sea and results represent a starting point to study PFAS time-trends in this vulnerable species.

20 May 2021 in Separations
Verified
Journal Article
Open access
PDF file
Stefano DugheriStefano Dugheri
Stefano Dugheri
Nicola MucciNicola Mucci
Nicola Mucci
Enrico MiniEnrico Mini
Enrico Mini
Donato SquillaciDonato Squillaci
Donato Squillaci
Giorgio MarrubiniGiorgio Marrubini
Giorgio Marrubini
Giulio ArcangeliGiulio Arcangeli
Giulio Arcangeli
Platinum-based antineoplastic drugs (PtADs) are among the most important and used families of chemotherapy drugs, which, even showing severe side effects and being hindered by drug resistance, are not likely to be replaced clinically any time soon. The growing interest in the occupational health community in antineoplastic drug (AD) surface contamination requires the development of increasingly fast and easy high-throughput monitoring methods, even considering the lack of harmonized legally binding regulation criteria. Thus, a wipe sampling method together with zwitterionic hydrophilic interaction liquid chromatography (HILIC-Z)–tandem mass spectrometry (MS/MS) analysis was developed for the simultaneous evaluation of oxaliplatin, cisplatin, and carboplatin surface contaminations. A design of experiments approach was used to optimize the chromatographic conditions. Limits of quantification ranging from 2 to 5 ng/mL were obtained from interday and intraday repetitions for oxaliplatin and carboplatin, and between 170 and 240 ng/mL for cisplatin. The wipe desorption procedure is equivalent to other AD sampling methods, enabling a fast sample preparation, with an LC-MS/MS analysis time of less than 7 min.

10 September 2021 in Separations
Verified
Journal Article
Open access
PDF file
Stefano DugheriStefano Dugheri
Stefano Dugheri
Nicola MucciNicola Mucci
Nicola Mucci
Donato SquillaciDonato Squillaci
Donato Squillaci
Giorgio MarrubiniGiorgio Marrubini
Giorgio Marrubini
GBGianluca Bartolucci
Gianluca Bartolucci
Giulio ArcangeliGiulio Arcangeli
Giulio Arcangeli
Growing attention on carcinogenicity and mutagenicity of antineoplastic drugs (ADs) from the International Agencies has led to the present strict safe handling and administration regulations. Accordingly, one of the most common ways to assess occupational exposure to these substances is to identify and quantify possible surface contamination inside hospital preparation and administration units. Thus, it is essential to develop a fast and high-throughput monitoring method capable of identifying a significant number of ADs. The present study reports developing a UHPLC–MS/MS analysis to screen 26 ADs surface contamination through wipe test sampling. A Cortecs UPLC T3 50 × 2.1 mm (1.6 µm) column was selected to perform the analysis, using the evaluations of previous studies and the Product Quality Research Institute (PQRI) database. The design of experiments (DoE) methodological approach was used to optimize the chromatographic conditions concerning the best separation between all ADs. The limits of quantification for the analytes were between the pg/mL and ng/mL orders, and the turnaround time was limited to about 15 min. The obtained accuracy was mostly between 90% and 110% for all the analytes, while the precision was under 10% and a low matrix effect was observed for said analytes. Only vindesine and docetaxel presented lower performances.