An injection-seeded high-repetition rate (∼10 kHz) Ti:sapphire laser with a spectral bandwidth of ∼20 MHz and an average output power of above 1.5 W has been developed. We report on its demonstration
The neutron profile monitor stably operated at a high-count-rate for deuterium operations in the Large Helical Device has been developed to enhance the research on the fast-ion confinement. It is composed of a multichannel collimator, scintillation-detectors, and a field programmable gate array circuit. The entire neutron detector system was tested using an accelerator-based neutron generator. This system stably acquires the pulse data without any data loss at high-count-rate conditions up to 8 × 105 counts per second.
A compact cavity ring-down spectrometer aimed at the detection of trace amounts of radiocarbon (14C) in biomedical samples is demonstrated. Rapid sampling, as required for large scale studies, is made possible by modifications to a CHNS elemental analyzer. After conversion of the carbon content of a sample into CO2, spectral analysis using a high-finesse cavity in conjunction with a quantum cascade laser system reveals the ratio of 14CO2 in relation to the stable isotopologues of 12C and 13C. Cooling and temperature stabilization of the cavity is achieved by a combination of liquid cooling and thermo-electric elements. The system is studied in terms of reproducibility, linearity, and sensitivity as well as contamination and memory effects of the sampling process. While the performance of the system is still limited mainly due to etaloning and other systematic effects, first spectra of biomedical samples, such as urine and feces, have been analyzed at 14C concentration levels above ten times natural abundance. Results are compared with those from a traditional liquid scintillation counter system. Possibilities for improvement of the sensitivity are discussed.
1 January 2013 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
A new laser ion source configuration based on resonant photoionization in a gas cell has been developed at RIBF RIKEN. This system is intended for the future PArasitic RI-beam production by Laser Ion-Source (PALIS) project which will be installed at RIKEN's fragment separator, BigRIPS. A novel implementation of differential pumping, in combination with a sextupole ion beam guide (SPIG), has been developed. A few small scroll pumps create a pressure difference from 1000 hPa - 10^-3 Pa within a geometry drastically miniaturized compared to conventional systems. This system can utilize a large exit hole for fast evacuation times, minimizing the decay loss for short-lived nuclei during extraction from a buffer gas cell, while sufficient gas cell pressure is maintained for stopping high energy RI-beams. In spite of the motion in a dense pressure gradient, the photo-ionized ions inside the gas cell are ejected with an assisting force gas jet and successfully transported to a high-vacuum region via SPIG followed by a quadrupole mass separator. Observed behaviors agree with the results of gas flow and Monte Carlo simulations
In this paper, we propose a path planning method for the localization of radiation sources using a mobile robot equipped with an imaging gamma-ray detector, which has a field of view in all directions. The ability to detect and localize radiation sources is essential for ensuring nuclear safety, security, and surveillance. To enable the autonomous localization of radiation sources, the robot must have the ability to automatically determine the next location for gamma ray measurement instead of following a predefined path. The number of incident events is approximated to be the squared inverse proportional to the distance between the radiation source and the detector. Therefore, the closer the distance to the source, the shorter the time required to obtain the same radiation counts measured by the detector. Hence, the proposed method is designed to reduce this distance to a position where a sufficient number of gamma-ray events can be obtained; then, a path to surround the radiation sources is generated. The proposed method generates this path by performing principal component analysis based on the results obtained from previous measurements. Both simulations and actual experiments demonstrate that the proposed method can automatically generate a measurement path and accurately localize radiation sources.
Mid-infrared laser absorption spectroscopy utilizing a high-finesse optical cavity enables high precision trace analysis of gas molecules. In particular, optical detection of radiocarbon (14C) based on cavity ringdown spectroscopy using a quantum cascade laser (QCL) is gaining attention as an alternative to accelerator mass spectrometry. This paper reports a compact-packaged narrow-linewidth QCL system utilizing resonant optical feedback from an external V-shaped cavity. Based on frequency noise analysis, the derived laser linewidth is 44 kHz for 100 μs integration time with the capability to perform seamless frequency scanning around 10 GHz. We installed this laser system within a table-top cavity ringdown spectrometer for 14CO2. A single-shot detection limit of 1.2 × 10−9 cm−1 Hz−1/2 leading to a detectable abundance evaluated from a noise analysis of 0.2 in fraction modern 14C for a 10-s averaging time was achieved. This capability of rapid analysis for 14CO2 is suitable for various applications requiring trace 14C analysis.
About Me
Department of Energy Engineering, Nagoya University
Department of Energy Engineering, Nagoya University