Michiharu Wada

Michiharu Wada

Auto-generated profile, based on publicly available information

Michiharu Wada

High Energy Accelerator Research Organization

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2024 in Nature
Verified
Journal Article
Closed access
PDF file
AYAtsushi Yamaguchi
Atsushi Yamaguchi
YSYudai Shigekawa
Yudai Shigekawa
HHHiromitsu Haba
Hiromitsu Haba
HKHidetoshi Kikunaga
Hidetoshi Kikunaga
KSKenji Shirasaki
Kenji Shirasaki
HKHidetoshi Katori
Hidetoshi Katori

31 March 2023 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
TNT. Niwase
T. Niwase
YWYutaka Watanabe
Yutaka Watanabe
YHY. Hirayama
Y. Hirayama
MMM. Mukai
M. Mukai
PSP. Schury
P. Schury
MWM. Wada
M. Wada
The new isotope U241 was synthesized and systematic atomic mass measurements of nineteen neutron-rich Pa-Pu isotopes were performed in the multinucleon transfer reactions of the U238+Pt198 system at the KISS facility. The present experimental results demonstrate the crucial role of the multinucleon transfer reactions for accessing unexplored neutron-rich actinide isotopes toward the N=152 shell gap in this region of nuclides.

21 November 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
MRM. Rosenbusch
M. Rosenbusch
MWM. Wada
M. Wada
SCS. Chen
S. Chen
ATA. Takamine
A. Takamine
SIS. Iimura
S. Iimura
HWH. Wollnik
H. Wollnik

1 February 2014 in International Journal of Mass Spectrometry
Verified
Journal Article
Open access
PSPeter Schury
Peter Schury
YIY. Ito
Y. Ito
MWM. Wada
M. Wada
HWH. Wollnik
H. Wollnik
We characterize the mass bandwidth of the a multi-reflection time-of-flight mass spectrograph, showing both the functional and useful mass bandwidth. We then demonstrate the use of a multi-reflection time-of-flight mass spectrograph to perform mass measurements in mass bands much wider than the mass bandwidth.Comment: 8 pages, 9 figure

5 January 2023 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
SIS. Iimura
S. Iimura
MRM. Rosenbusch
M. Rosenbusch
ATA. Takamine
A. Takamine
YTY. Tsunoda
Y. Tsunoda
MWM. Wada
M. Wada
HWH. Wollnik
H. Wollnik
The atomic masses of Sc55, Ti56,58, and V56−59 have been determined using the high-precision multireflection time-of-flight technique. The radioisotopes have been produced at RIKEN’s Radioactive Isotope Beam Factory (RIBF) and delivered to the novel designed gas cell and multireflection system, which has been recently commissioned downstream of the ZeroDegree spectrometer following the BigRIPS separator. For Ti56,58 and V56−59, the mass uncertainties have been reduced down to the order of 10 keV, shedding new light on the N=34 shell effect in Ti and V isotopes by the first high-precision mass measurements of the critical species Ti58 and V59. With the new precision achieved, we reveal the nonexistence of the N=34 empirical two-neutron shell gaps for Ti and V, and the enhanced energy gap above the occupied νp3/2 orbit is identified as a feature unique to Ca. We perform new Monte Carlo shell model calculations including the νd5/2 and νg9/2 orbits and compare the results with conventional shell model calculations, which exclude the νg9/2 and the νd5/2 orbits. The comparison indicates that the shell gap reduction in Ti is related to a partial occupation of the higher orbitals for the outer two valence neutrons at N=34.

1 January 2013 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Verified
Journal Article
Open access
TST. Sonoda
T. Sonoda
MWM. Wada
M. Wada
Hideki TomitaHideki Tomita
Hideki Tomita
CSC. Sakamoto
C. Sakamoto
TTT. Takatsuka
T. Takatsuka
ATA. Takamine
A. Takamine
A new laser ion source configuration based on resonant photoionization in a gas cell has been developed at RIBF RIKEN. This system is intended for the future PArasitic RI-beam production by Laser Ion-Source (PALIS) project which will be installed at RIKEN's fragment separator, BigRIPS. A novel implementation of differential pumping, in combination with a sextupole ion beam guide (SPIG), has been developed. A few small scroll pumps create a pressure difference from 1000 hPa - 10^-3 Pa within a geometry drastically miniaturized compared to conventional systems. This system can utilize a large exit hole for fast evacuation times, minimizing the decay loss for short-lived nuclei during extraction from a buffer gas cell, while sufficient gas cell pressure is maintained for stopping high energy RI-beams. In spite of the motion in a dense pressure gradient, the photo-ionized ions inside the gas cell are ejected with an assisting force gas jet and successfully transported to a high-vacuum region via SPIG followed by a quadrupole mass separator. Observed behaviors agree with the results of gas flow and Monte Carlo simulations