Changli Zhou

Changli Zhou


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
JYJiangle Yi
Jiangle Yi
ZLZhen Liu
Zhen Liu
JLJianhui Liu
Jianhui Liu
HLHanbiao Liu
Hanbiao Liu
FXFangquan Xia
Fangquan Xia
CZChangli Zhou
Changli Zhou

1 March 2019 in Analytica Chimica Acta
Verified
Journal Article
Closed access
XQXueying Qiao
Xueying Qiao
FXFangquan Xia
Fangquan Xia
DTDong Tian
Dong Tian
PCPeipei Chen
Peipei Chen
JLJianhui Liu
Jianhui Liu
CZChangli Zhou
Changli Zhou

25 March 2009 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
CZChangli Zhou
Changli Zhou
ZLZhen Liu
Zhen Liu
YDYanmin Dong
Yanmin Dong
DLDongmei Li
Dongmei Li

1 June 2019 in Analytical Biochemistry
Verified
Journal Article
Closed access
PCPeipei Chen
Peipei Chen
XHXiaoxia Hua
Xiaoxia Hua
JLJianhui Liu
Jianhui Liu
HLHanbiao Liu
Hanbiao Liu
FXFangquan Xia
Fangquan Xia
CZChangli Zhou
Changli Zhou

8 September 2022 in Analytica Chimica Acta
Verified
Journal Article
Closed access
DMDongxiao Ma
Dongxiao Ma
JLJianhui Liu
Jianhui Liu
HLHanbiao Liu
Hanbiao Liu
JYJiangle Yi
Jiangle Yi
FXFangquan Xia
Fangquan Xia
CZChangli Zhou
Changli Zhou

16 February 2016 in RSC Advances
Verified
Journal Article
Closed access
PDF file
XZXiangli Zheng
Xiangli Zheng
XHXiaoxia Hua
Xiaoxia Hua
XQXueying Qiao
Xueying Qiao
FXFangquan Xia
Fangquan Xia
DTDong Tian
Dong Tian
CZChangli Zhou
Changli Zhou
A simple, signal-off electrochemiluminescence (ECL) immunosensor for sensitive and selective detection of alpha fetoprotein (AFP) was developed based on gold nanoparticle (AuNPs) modified graphite-like carbon nitride nanosheet (g-C3N4 NSs) nanohybrids (Au-g-C3N4 NHs). Compared to the g-C3N4 NS modified glassy carbon electrode (GCE), the ECL intensity is more obvious at the Au-g-C3N4 NH modified GCE due to the fact that AuNPs can promote electron transfer and electrocatalytic reduction of S2O8 2− to produce large amounts of hole donor (SO4˙−). Results demonstrated that the ECL signal of the g-C3N4 NSs decreased due to the interaction between antibody and antigen on the modified electrode. Thus, an ECL immunosensor for the detection of AFP was realized by monitoring the ECL intensity change of g-C3N4 NSs. The factors influencing the performance of the immunosensor were investigated in detail. Under optimal conditions, the proposed biosensor achieved a wide line from 0.001 to 5.0 ng mL−1 with a detection limit of 0.0005 ng mL−1. Furthermore, the ECL immunosensor was successfully applied to the determination of AFP in serum samples, providing a promising effective strategy for AFP detection.