Peng Un Mak

Peng Un Mak

orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2012 in International Journal of Psychophysiology
Verified
Journal Article
Closed access
WNWenya Nan
Wenya Nan
JRJoão Rodrigues
João Rodrigues
JMJiali Ma
Jiali Ma
XQXiaoting Qu
Xiaoting Qu
FWFeng Wan
Feng Wan
ARAgostinho Rosa
Agostinho Rosa

6 January 2020 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
CWChi Man Wong
Chi Man Wong
FWFeng Wan
Feng Wan
BWBoyu Wang
Boyu Wang
ZWZe Wang
Ze Wang
WNWenya Nan
Wenya Nan
ARAgostinho Rosa
Agostinho Rosa
Objective . Latest target recognition methods that are equipped with learning from the subject’s calibration data, represented by the extended canonical correlation analysis (eCCA) and the ensemble task-related component analysis (eTRCA), can achieve extra high performance in the steady-state visual evoked potential (SSVEP)-based brain–computer interfaces (BCIs), however their performance deteriorate drastically if the calibration trials are insufficient. This paper develops a new scheme to learn from limited calibration data. Approach . A learning across multiple stimuli scheme is proposed for the target recognition methods, which applies to learning the data corresponding to not only the target stimulus but also the other stimuli. The resulting optimization problems can be simplified and solved utilizing the prior knowledge and properties of SSVEPs across different stimuli. With the new learning scheme, the eCCA and the eTRCA can be extended to the multi-stimulus eCCA (ms-eCCA) and the multi-stimulus eTRCA (ms-eTRCA), respectively, as well as a combination of them (i.e. ms-eCCA+ms-eTRCA) that incorporates their merits. Main results . Evaluation and comparison using an SSVEP-BCI benchmark dataset with 35 subjects show that the ms-eCCA (or ms-eTRCA) performs significantly better than the eCCA (or eTRCA) method while the ms-eCCA+ms-eTRCA performs the best. With the learning across stimuli scheme, the existing target recognition methods can be further improved in terms of the target recognition performance and the ability against insufficient calibration. Significance . A new learning scheme is proposed towards the efficient use of the calibration data, providing enhanced performance and saving calibration time in the SSVEP-based BCIs.

5 April 2012 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
CIChio-In Ieong
Chio-In Ieong
PMPui-In Mak
Pui-In Mak
CLChi-Pang Lam
Chi-Pang Lam
CDCheng Dong
Cheng Dong
MVMang-I Vai
Mang-I Vai
RMRui P. Martins
Rui P. Martins
Healthcare electronics count on the effectiveness of the on-patient signal preprocessing unit to moderate the wireless data transfer for better power efficiency. In order to reduce the system power in long-time ECG acquisition, this work describes an on-patient QRS detection processor for arrhythmia monitoring. It extracts the concerned ECG part, i.e., the RR-interval between the QRS complex for evaluating the heart rate variability. The processor is structured by a scale-3 quadratic spline wavelet transform followed by a maxima modulus recognition stage. The former is implemented via a symmetric FIR filter, whereas the latter includes a number of feature extraction steps: zero-crossing detection, peak (zero-derivative) detection, threshold adjustment and two finite state machines for executing the decision rules. Fabricated in 0.35-μm CMOS the 300-Hz processor draws only 0.83 μW, which is favorably comparable with the prior arts. In the system tests, the input data is placed via an on-chip 10-bit SAR analog-to-digital converter, while the output data is emitted via an off-the-shelf wireless transmitter (TI CC2500) that is configurable by the processor for different data transmission modes: 1) QRS detection result, 2) raw ECG data or 3) both. Validated with all recordings from the MIT-BIH arrhythmia database, 99.31% sensitivity and 99.70% predictivity are achieved. Mode 1 with solely the result of QRS detection exhibits 6× reduction of system power over modes 2 and 3.

1 July 2012
Verified
Conference Paper
Closed access
YLYue Liu
Yue Liu
XJXiao Jiang
Xiao Jiang
TCTeng Cao
Teng Cao
FWFeng Wan
Feng Wan
PMPeng Un Mak
Peng Un Mak
MVMang I Vai
Mang I Vai
In recent years, steady-state visual evoked potential (SSVEP) based brain-computer interface (BCI) has received much attentions. However, most SSVEP based BCI devices are not portable and have high price, which are not suitable to be used for clinical and commercial purpose. Thanks to the low cost and portable Emotiv EPOC, it brings BCI into daily life. In this paper, SSVEP based BCI through Emotiv EPOC is implemented. BCI 2000 is employed to connect Emotiv EPOC and Matlab to implement the online system. The online experiments have the accuracy of 95.83±3.59 %, information transfer rate (ITR) with 22.85±1.85 bits/min and detection duration of 5.25±2.14 sec.

1 November 2011 in IEEE Transactions on Information Technology in Biomedicine
Verified
Journal Article
Closed access
SPSio Hang Pun
Sio Hang Pun
YGYue Ming Gao
Yue Ming Gao
PMPeng Un Mak
Peng Un Mak
MVM. I. Vai
M. I. Vai
MDMin Du
Min Du
In recent years, the increasing number of wearable devices on human has been witnessed as a trend. These devices can serve for many purposes: personal entertainment, communication, emergency mission, health care supervision, delivery, etc. Sharing information among the devices scattered across the human body requires a body area network (BAN) and body sensor network (BSN). However, implementation of the BAN/BSN with the conventional wireless technologies cannot give optimal result. It is mainly because the high requirements of light weight, miniature, energy efficiency, security, and less electromagnetic interference greatly limit the resources available for the communication modules. The newly developed intra-body communication (IBC) can alleviate most of the mentioned problems. This technique, which employs the human body as a communication channel, could be an innovative networking method for sensors and devices on the human body. In order to encourage the research and development of the IBC, the authors are favorable to lay a better and more formal theoretical foundation on IBC. They propose a multilayer mathematical model using volume conductor theory for galvanic coupling IBC on a human limb with consideration on the inhomogeneous properties of human tissue. By introducing and checking with quasi-static approximation criteria, Maxwell's equations are decoupled and capacitance effect is included to the governing equation for further improvement. Finally, the accuracy and potential of the model are examined from both in vitro and in vivo experimental results.

12 March 2013 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
TZTan-Tan Zhang
Tan-Tan Zhang
PMPui-In Mak
Pui-In Mak
MVMang-I Vai
Mang-I Vai
PMPeng Un Mak
Peng Un Mak
MLMan-Kay Law
Man-Kay Law
RMRui P. Martins
Rui P. Martins
Most biopotential readout front-ends rely on the g m- C lowpass filter (LPF) for forefront signal conditioning. A small g m realizes a large time constant ( τ = C / g m) suitable for ultra-low-cutoff filtering, saving both power and area. Yet, the noise and linearity can be compromised, given that each g m cell can involve one or several noisy and nonlinear V- I conversions originated from the active devices. This paper proposes the subthreshold-source-follower (SSF) Biquad as a prospective alternative. It features: 1) a very small number of active devices reducing the noise and nonlinearity footsteps; 2) No explicit feedback in differential implementation, and 3) extension of filter order by cascading. This paper presents an in-depth treatment of SSF Biquad in the nW-power regime, analyzing its power and area tradeoffs with gain, linearity and noise. A gain-compensation (GC) scheme addressing the gain-loss problem of NMOS-based SSF Biquad due to the body effect is also proposed. Two 100-Hz 4th-order Butterworth LPFs using the SSF Biquads with and without GC were fabricated in 0.35- μm CMOS. Measurement results show that the non-GC (GC) LPF can achieve a DC gain of -3.7 dB (0 dB), an input-referred noise of 36 μV rms (29 μV rms ), a HD3@60 Hz of -55.2 dB ( - 60.7 dB) and a die size of 0.11 mm 2 (0.08 mm 2 ). Both LPFs draw 15 nW at 3 V. The achieved figure-of-merits (FoMs) are favorably comparable with the state-of-the-art.