Jorge Zamorano-Fernández

Prof. Jorge Zamorano-Fernández

Hospital Universitario La Paz

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2019 in Child's Nervous System
Verified
Journal Article
Closed access
PDF file
SPSmruti K. Patel
Smruti K. Patel
Jorge Zamorano-FernándezJorge Zamorano-Fernández
Jorge Zamorano-Fernández
UNUsha Nagaraj
Usha Nagaraj
KBKarin S. Bierbrauer
Karin S. Bierbrauer
FMFrancesco T. Mangano
Francesco T. Mangano

25 May 2021 in Biomedicines
Verified
Journal Article
Open access
PDF file
VFVictor Farré
Victor Farré
APAlejandra Palomino
Alejandra Palomino
PNPaloma Narros
Paloma Narros
ARAna Belen Lopez Rodriguez
Ana Belen Lopez Rodriguez
CDCéline Decouty
Céline Decouty
Javier EgeaJavier Egea
Javier Egea
Traumatic brain injury (TBI) is one of the leading causes of mortality and disability worldwide without any validated biomarker or set of biomarkers to help the diagnosis and evaluation of the evolution/prognosis of TBI patients. To achieve this aim, a deeper knowledge of the biochemical and pathophysiological processes triggered after the trauma is essential. Here, we identified the serum amyloid A1 protein-Toll-like receptor 4 (SAA1-TLR4) axis as an important link between inflammation and the outcome of TBI patients. Using serum and mRNA from white blood cells (WBC) of TBI patients, we found a positive correlation between serum SAA1 levels and injury severity, as well as with the 6-month outcome of TBI patients. SAA1 levels also correlate with the presence of TLR4 mRNA in WBC. In vitro, we found that SAA1 contributes to inflammation via TLR4 activation that releases inflammatory cytokines, which in turn increases SAA1 levels, establishing a positive proinflammatory loop. In vivo, post-TBI treatment with the TLR4-antagonist TAK242 reduces SAA1 levels, improves neurobehavioral outcome, and prevents blood–brain barrier disruption. Our data support further evaluation of (i) post-TBI treatment in the presence of TLR4 inhibition for limiting TBI-induced damage and (ii) SAA1-TLR4 as a biomarker of injury progression in TBI patients.

1 June 2021 in Journal of neurosurgery. Pediatrics
Verified
Journal Article
Closed access
PDF file
SPSmruti K. Patel
Smruti K. Patel
Jorge Zamorano-FernándezJorge Zamorano-Fernández
Jorge Zamorano-Fernández
CMCarlie McCoy
Carlie McCoy
JSJesse Skoch
Jesse Skoch
OBJECTIVE: External magnetic forces can have an impact on programmable valve mechanisms and potentially alter the opening pressure. As wearable technology has begun to permeate mainstream living, there is a clear need to provide information regarding safety of these devices for use near a programmable valve (PV). The aim of this study was to evaluate the magnetic fields of reference devices using smartphone-integrated magnetometers and compare the results with published shunt tolerances. METHODS: Five smartphones from different manufacturers were used to evaluate the magnetic properties of various commonly used (n = 6) and newer-generation (n = 10) devices using measurements generated from the internal smartphone magnetometers. PV tolerance testing using calibrated magnets of varying field strengths was also performed by smartphone magnetometers. RESULTS: All tested smartphone-integrated magnetometers had a factory sensor saturation point at around 5000 µT or 50 Gauss (G). This is well below the threshold at which a magnet can potentially deprogram a shunt, based on manufacturer reports as well as the authors’ experimental data with a threshold of more than 300 G. While many of the devices did saturate the smartphone sensors at the source, the magnetic flux density of the objects decreases significantly at 2 inches. CONCLUSIONS: The existence of an upper limit on the magnetometers of all the smartphones used, although well below the published deprogramming threshold for modern programmable valves, does not allow us to give precise recommendations on those devices that saturate the sensor. Based on the authors’ experimental data using smartphone-integrated magnetometers, they concluded that devices that measure < 40 G can be used safely close to a PV.

29 May 2026 in BMJ Case Reports
Verified
Journal Article
Closed access
PDF file
JCJorge Bedia Cadelo
Jorge Bedia Cadelo
PFPablo García Feijoo
Pablo García Feijoo
Jorge Zamorano-FernándezJorge Zamorano-Fernández
Jorge Zamorano-Fernández
AGAlberto Isla Guerrero
Alberto Isla Guerrero
A boy in his early teens presented with transient visual disturbances and headache. Brain imaging revealed bilateral occipital infarctions, while vascular studies demonstrated bilateral V3 vertebral artery wall abnormalities with pseudoaneurysm formation associated with C1-C2 rotatory subluxation. Initial conservative management, including resting and a rigid cervical brace, failed to prevent vascular progression. The patient underwent posterior C1-C2 fixation to address the underlying mechanical cause. Follow-up CT angiography 1 year after surgery demonstrated complete resolution of the pseudoaneurysm and near-normalisation of both vertebral artery walls. At 18 months of follow-up, he remained asymptomatic, with no recurrent ischaemic events and no progression of the pre-existing visual deficit. This case highlights the importance of considering dynamic atlantoaxial instability in children with posterior circulation strokes and supports surgical stabilisation as definitive etiological treatment in selected cases.

22 June 2026 in Brain Pathology
Verified
Journal Article
Open access
SMSamuel López Muñoz
Samuel López Muñoz
ABAlberto Berjón
Alberto Berjón
CRCarlos Rodríguez-Antolín
Carlos Rodríguez-Antolín
CLClaudia Sánchez Lara
Claudia Sánchez Lara
MMMarta Mendiola
Marta Mendiola
IRIsabel Esteban Rodríguez
Isabel Esteban Rodríguez

4 December 2025 in Children
Verified
Journal Article
Open access
PDF file
EGElena M Gomez Garcia
Elena M Gomez Garcia
MGMaria Granados
Maria Granados
JSJavier M. Saceda
Javier M. Saceda
MNMaria Nieves-Moreno
Maria Nieves-Moreno
Jorge Zamorano-FernándezJorge Zamorano-Fernández
Jorge Zamorano-Fernández
Susana NovalSusana Noval
Susana Noval
Background/Objectives: Pediatric orbital tumors are rare and complex, requiring multidisciplinary care at specialized centers. Contemporary treatment paradigms emphasize centralized care delivery through experienced multidisciplinary teams to optimize patient outcomes. Recent advances in surgical planning technologies and intraoperative navigation systems have substantially enhanced surgical safety through improvement in tumor resection and reconstruction and reduction in complications, including recurrence of the lesion. Computed-aided surgical technologies enable precise virtual planning, minimally invasive approaches and more precise reconstruction methods when necessary by mean of patient-specific cutting guides, premolded orbital plates or individual patient solutions (IPS) prosthesis. Three-dimensional biomodelling visualizes tumor architecture and aids localization while preserving neurovascular structures, and real-time neuronavigation improves safety and efficacy. Methods: We conducted a retrospective analysis of 98 pediatric patients with orbital tumors treated between 2014 and 2025 at a tertiary center to evaluate the use of computed-assisted surgical technologies and the indications for treatment. Inclusion criteria comprised all cases where computer-assisted techniques were employed. Patients were classified into two groups: Group 1—intraconal or extensive periorbital lesions with eye-sparing intent treated via craniofacial approaches; Group 2—periorbital tumors with orbital wall involvement, to analyze the use of the different technologies. Data collected included tumor age, type, location, technology used, adjunctive treatments, and postoperative outcomes. Results: Twelve patients underwent computer-assisted surgery. Technologies employed over the last six years included intraoperative navigation, 3D planning with/without tumor segmentation, orbital-wall reconstruction by mirroring, IPS or titanium mesh bending, and preoperative biomodelling. Patients were grouped by tumor location and treatment goals: Group 1—intraorbital lesions (primarily intraconal or 270–360° involvement), including one case of orbital encephalocele treated transcranially; Group 2—periorbital tumors with orbital-wall destruction, treated mainly via midfacial approaches. Intraoperative navigation was used in 10/12 cases (8/11 with tumor segmentation); in 3 cases with ill-defined margins, navigation localized residual tumor. Virtual surgery predominated in Group 2 (4 patients) and one in Group 1, combined with cutting guides for margins and Individual Prosthetic Solutions (IPS) prosthesis fitting (two patients: titanium and PEEK). In two cases, virtual plans were performed, STL models printed, and premolded titanium meshes used. No complications related to tumor persistence or orbital disturbance were observed. Conclusions: Advanced surgical technologies substantially enhance safety, efficiency, and outcomes in pediatric orbital tumors. Technology-assisted approaches represent a paradigm shift in this complex field. Additional studies are needed to establish evidence-based protocols for systematic integration of technology in pediatric orbital tumor management.